TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 FOUR-CHANNEL AUTOMOTIVE DIGITAL AMPLIFIERS FEATURES • • • • • • • • • • • • • • • TAS5414 – Single-Ended Input TAS5424 – Differential Input Four-Channel Digital Power Amplifier Four Analog Inputs, Four BTL Power Outputs Typical Output Power per Channel at 10% THD+N – 28 W/Ch Into 4 Ω at 14.4 Vdc – 45 W/Ch Into 2 Ω at 14.4 Vdc – 58 W/Ch Into 4 Ω at 21 Vdc – 116 W/Ch Into 2 Ω at 21 Vdc PBTL Channels Can Be Paralleled (PBTL) for 1-Ω Applications THD+N < 0.02%, 1 kHz, 1 W Into 4 Ω Patented Pop- and Click-Reduction Technology – Soft Muting With Gain Ramp Control – Common-Mode Ramping Patented AM Interference Avoidance Patented Cycle-by-Cycle Current Limit 75-dB PSRR Four-Address I2C Serial Interface for Device Configuration and Control Configurable Channel Gains: 12-dB, 20-dB, 26-dB, 32-dB Load Diagnostic Functions: – Output Open and Shorted Load – Output-to-Power and -to-Ground Shorts – Patented Tweeter Detection Protection and Monitoring Functions: – Short-Circuit Protection – Load-Dump Protection to 50 V – Fortuitous Open Ground and Power Tolerant – Patented Output DC Level Detection While Music Playing – Overtemperature Protection – Over- and Undervoltage Conditions – Clip Detection • • • • • • 36-Pin PSOP3 (DKD) Power SOP Package With Heat Slug Up for the TAS5414 44-Pin PSOP3 (DKD) Power SOP Package With Heat Slug Up for the TAS5424 Designed for Automotive EMC Requirements Pb-Free Soldering Supported ISO9000:2002 TS16949 Certified –40°C to 105°C Ambient Temperature Range APPLICATIONS • High-power OEM/retail head units and amplifier modules where feature densities and system configurations require reduction in heat from the audio power amplifier DESCRIPTION The TAS5414 and TAS5424 are four-channel digital audio amplifiers designed for use in automotive head units and external amplifier modules. The TAS5414 and TAS5424 provide four channels at 23 W continuously into 4 Ω at less than 1% THD+N from a 14.4-V supply. Each channel can also deliver 38 W into 2 Ω at 1% THD+N. The TAS5414 uses single-ended analog inputs, while the TAS5424 employs differential inputs for increased immunity to common-mode system noise. The digital PWM topology of the TAS5414 and TAS5424 provides dramatic improvements in efficiency over traditional linear amplifier solutions. This reduces the power dissipated by the amplifier by a factor of ten under typical music playback conditions. High efficiency is accomplished without the need for complicated power-supply schemes. Multiple TAS5414s or TAS5424s can be synchronized to meet high-channel-count applications. The TAS5414 and TAS5424 incorporate all the functionality needed to perform in the demanding OEM applications area. They have built-in load diagnostic functions for detecting and diagnosing misconnected outputs to help to reduce test time during the manufacturing process. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2007, Texas Instruments Incorporated TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 TAS5414 FUNCTIONAL BLOCK DIAGRAM 3.3 V – 5 V TAS5414-36 Pins Pull-Up Resistors System mP AVDD (6.5 V) SDA SCL STANDBY Supplies and References D_BYP A_BYP DVDD (3.3 V) 2 I C SGND OverTemp Warn/SD FAULT CLIP_OTW REXT VREF and IREF I2C ADDR “0” – “3” Fault and Timing Logic Channel Utilities GND CP AVDD Over/Under Voltage CPC_TOP PVDD Load Dump OSC_SYNC Charge Pump Osc and Clock GND/SGND PGND CPC_BOT CP Battery 8 VDC – 22 VDC Channel 1 of 4 MUTE Optional Load Diagnostics and Fault Monitors Open/Short OC Timer Diagnostic DC Detect AVSS Clip Detect FLV RLV FRV RRV Radio DSP Signal Path PVDD Current Limit IN1_P IN2_P IN3_P IN4_P IN_M OUT1_P PreAmp Tweeter Detect PWM Gate Driver Feedback OUT1_M PGND Channels 2, 3, 4: Same as Ch 1 B0198-01 2 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 TAS5424 FUNCTIONAL BLOCK DIAGRAM 3.3 V – 5 V TAS5414-36 Pins Pull-Up Resistors System mP AVDD (6.5 V) SDA SCL STANDBY Supplies and References D_BYP A_BYP DVDD (3.3 V) 2 I C SGND OverTemp Warn/SD FAULT CLIP_OTW REXT VREF and IREF I2C ADDR “0” – “3” Fault and Timing Logic Channel Utilities GND CP AVDD Over/Under Voltage CPC_TOP PVDD Load Dump OSC_SYNC Charge Pump Osc and Clock GND/SGND PGND CPC_BOT CP Battery 8 VDC – 22 VDC Channel 1 of 4 MUTE Optional Load Diagnostics and Fault Monitors Open/Short OC Timer Diagnostic DC Detect Clip Detect Signal Path PVDD Current Limit IN1_P Audio Input IN1_M OUT1_P PreAmp Tweeter Detect PWM Gate Driver Feedback OUT1_M PGND Channels 2, 3, 4: Same as Ch 1 B0198-02 Submit Documentation Feedback 3 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 PIN ASSIGNMENTS AND FUNCTIONS The pin assignments for the TAS5414 and TAS5424 are shown as follows. TAS5414 DKD PACKAGE (TOP VIEW) OSC_SYNC I2C_ADDR SDA SCL FAULT MUTE STANDBY D_BYP CLIP_OTW GND SGND REXT A_BYP IN1_P IN2_P IN_M IN3_P IN4_P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 TAS5424 DKD PACKAGE (TOP VIEW) 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 PVDD PVDD OUT1_M OUT1_P PGND OUT2_M OUT2_P CPC_TOP CP CPC_BOT PGND OUT3_M OUT3_P PGND OUT4_M OUT4_P PVDD PVDD P0018-03 OSC_SYNC I2C_ADDR SDA SCL FAULT MUTE GND STANDBY D_BYP CLIP_OTW GND SGND REXT A_BYP IN1_P IN1_M IN2_P IN2_M IN3_P IN3_M IN4_P IN4_M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 PVDD PVDD PVDD OUT1_M OUT1_P PGND PGND OUT2_M OUT2_P CPC_TOP CP CP_BOT PGND OUT3_M OUT3_P PGND PGND OUT4_M OUT4_P PVDD PVDD PVDD P0055-01 4 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Table 1. TERMINAL FUNCTIONS TERMINAL NAME TAS5414 NO. TAS5424 NO. TYPE (1) A_BYP 13 14 PBY Bypass capacitor for the AVDD analog regulator CLIP_OTW 9 10 DO Open-drain CLIP, OTW, or logical OR of the CLIP and OTW outputs. It also reports tweeter detection during tweeter mode. CP 28 34 CP Top of main storage capacitor for charge pump (bottom goes to PVDD) CPC_BOT 27 33 CP Bottom of flying capacitor for charge pump CPC_TOP 29 35 CP Top of flying capacitor for charge pump D_BYP 8 9 PBY Bypass pin for DVDD regulator output FAULT 5 5 DO Global fault output (open drain): UV, OV, OTSD, OCSD, DC GND 10 7, 11 DG Ground I2C_ADDR 2 2 AI I2C address bit IN1_M N/A 16 AI Inverting analog input for channel 1 (TAS5424 only) IN1_P 14 15 AI Non-inverting analog input for channel 1 IN2_M N/A 18 AI Inverting analog input for channel 2 (TAS5424 only) IN2_P 15 17 AI Non-inverting analog input for channel 2 IN3_M N/A 20 AI Inverting analog input for channel 3 (TAS5424 only) IN3_P 17 19 AI Non-inverting analog input for channel 3 IN4_M N/A 22 AI Inverting analog input for channel 4 (TAS5424 only) IN4_P 18 21 AI Non-inverting analog input for channel 4 IN_M 16 N/A ARTN MUTE 6 6 AI OSC_SYNC 1 1 DI/DO OUT1_M 34 41 PO – polarity output for bridge 1 OUT1_P 33 40 PO + polarity output for bridge 1 OUT2_M 31 37 PO – polarity output for bridge 2 OUT2_P 30 36 PO + polarity output for bridge 2 OUT3_M 25 31 PO – polarity output for bridge 3 OUT3_P 24 30 PO + polarity output for bridge 3 OUT4_M 22 27 PO – polarity output for bridge 4 OUT4_P 21 26 PO + polarity output for bridge 4 PGND 23, 26, 32 28, 29, 32, 38, 39 PGND Power GND PVDD 19, 20, 35, 36 23, 24, 25, 42, 43, 44 PWR PVDD supply REXT 12 13 AI Precision resistor pin to set clock frequency SCL 4 4 DI I2C clock input from system I2C master SDA 3 3 DI/DO I2C data I/O for communication with system I2C master SGND 11 12 AG/DG Signal ground (analog and digital signal ground) STANDBY 7 8 DI (1) DESCRIPTION Signal return for the 4 analog channel inputs (TAS5414 only) Gain ramp control: mute (low), play (high) Oscillator sync input from master or output to slave amplifiers (20 MHz divided by 5, 6, or 7) Active-low STANDBY pin. Standby (low), power up (high) DI = digital input, DO = digital output, AI = analog input, ARTN = analog signal return, PWR = power supply, PGND = power ground, PBY = power bypass, PO = power output, AG = analog ground, DG = digital ground, CP = charge pump. Submit Documentation Feedback 5 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 ABSOLUTE MAXIMUM RATINGS over operating free-air temperature range (unless otherwise noted) VALUE UNIT –0.3 to 30 V –1 to 50 V PVDD DC supply voltage range Relative to PGND PVDDMAX Pulsed supply voltage range t ≤ 100 ms exposure PVDDRAMP Supply voltage ramp rate Voltage rising up to PVDDMAX IPVDD Externally imposed dc supply current per PVDD or PGND pin IPVDD_MAX Pulsed supply current per PVDD pin (one shot) IO Maximum allowed dc current per output pin IO_MAX (1) Pulsed output current per output pin (single pulse) t < 100 ms ±17 A IIN_MAX Maximum current, all digital and analog input pins (2) DC or pulsed ±1 mA IMUTE_MAX Maximum current on MUTE pin DC or pulsed ±20 mA IIN_ODMAX Maximum sinking current for open-drain pins 7 mA VLOGIC Input voltage range for logic pin relative to SGND (SCL and SDA pins) Supply voltage range: 6.5 V < PVDD < 24 V –0.3 to 7 V VI2C_ADDR Input voltage range for I2C_ADDR pin relative to SGND Supply voltage range: 6.5 V < PVDD < 24 V –0.3 to 7 V VSTANDBY Input voltage range for STANDBY pin Supply voltage range: 6.5 V < PVDD < 24V –0.3 to 5.8 V VOSC_SYNC Input voltage range for OSC_SYNC pin relative to SGND Supply voltage range: 6.5 V < PVDD < 24 V –0.3 to 3.6 V VAIN_MAX Maximum instantaneous input voltage (per pin), analog input pins Supply voltage range: 6.5 V < PVDD < 24 V 6.5 V VAIN_AC_MAX_5414 Maximum ac coupled input voltage for TAS5414 (2), analog input pins Supply voltage range: 6.5 V < PVDD < 24 V 1.9 Vrms VAIN_AC_MAX_5424 Maximum ac coupled differential input voltage for TAS5424 (2), Supply voltage range: analog input pins 6.5 V < PVDD < 24 V 3.8 (1.9 per pin) Vrms VAIN_DC Input voltage range for analog pin relative to AGND (INx pins) –0.3 to 6.5 V TJ Maximum operating junction temperature range –55 to 150 °C Tstg Storage temperature range –55 to 150 °C TSOLDER Lead temperature during soldering 1,6 mm (1/16 inch) from case for 10 seconds 260 °C Power dissipation Continuous power dissipation 80 W (1) (2) t < 100 ms Supply voltage range: 6.5 V < PVDD < 24 V Tcase = 70°C 25 V/ms ±12 A 17 A ± 13.5 A Pulsed current ratings are maximum survivable currents externally applied to the TAS5414 and TAS5424. High currents may be encountered during reverse battery, fortuitous open ground, and fortuitous open supply fault conditions. See Application Information section for information on analog input voltage and ac coupling. THERMAL CHARACTERISTICS 6 PARAMETER VALUE UNIT RθJC Junction-to-case (heat slug) thermal resistance 1 °C/W RθJA Junction-to-ambient thermal resistance This device is not intended to be used without a heatsink. Therefore, RθJA is not specified. See the Thermal Information section. °C/W Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 RECOMMENDED OPERATING CONDITIONS PVDDOP (1) DC supply voltage range relative to PGND PVDDI2C DC supply voltage range for I2C reporting (2) Analog audio input signal level (TAS5414) AC-coupled input voltage VAIN_5424(2) Analog audio input signal level (TAS5424) AC-coupled input voltage fAUDIO_TW Audio frequency for tweeter detect TA Ambient temperature VAIN_5414 MIN TYP MAX 8 14.4 22 V 6 14.4 26.5 V 0 0.25–1 (3) Vrms 0 0.5–2(3) Vrms 25 kHz –40 105 °C –40 115 °C 10 An adequate heat sink is required to keep TJ within specified range UNIT 20 TJ Junction temperature RL Nominal speaker load impedance 2 4 VPU Pullup voltage supply (for open-drain logic outputs) 3 3.3 or 5 5.5 V 10 50 100 kΩ 1 5 10 kΩ 100 kΩ RPU_EXT External pullup resistor on open-drain logic outputs RPU_I2C I2C pullup resistance on SDA and SCL pins Resistor connected between open-drain logic output and VPU supply Ω I2C RI2C_ADD Total resistance of voltage divider for address slave 1 or slave 2, connected between D_BYP and SGND pins RREXT External resistance on REXT pin 20.2 kΩ CD_BYP External capacitance on D_BYP pin 10 120 nF CA_BYP External capacitance on A_BYP pin 10 120 nF CIN External capacitance to analog input pin in series with input signal CFLY Flying capacitor on charge pump 0.47 1 1.5 µF CP Charge pump capacitor 0.47 1 1.5 µF CMUTE Capacitance on MUTE pin 3.3 330 nF COSCSYNC_MAX Allowed loading capacitance on OSC_SYNC pin 5 pF (1) (2) (3) 10 1% tolerance required 19.8 20 µF 1 The Recommended Operating Conditions table specifies only that the device is functional in the given range. See the Electrical Characteristics table for specified performance limits. Signal input for full unclipped output with gains of 32 dB, 26 dB, 20 dB, and 12 dB Maximum recommended input voltage is determined by the gain setting. Submit Documentation Feedback 7 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 ELECTRICAL CHARACTERISTICS Test conditions (unless otherwise noted): TCase = 25°C, PVDD = 14.4 V, RL = 4 Ω, fS = 417 kHz, Rext = 20 kΩ, master mode operation (see application diagram) PARAMETER TEST CONDITIONS MIN TYP MAX 240 300 UNIT OPERATING CURRENT IPVDD_IDLE IPVDD_Hi-Z IPVDD_STBY All four channels running in MUTE mode PVDD idle current All four channels in Hi-Z mode 80 STANDBY mode, TJ ≤ 85°C PVDD standby current 2 20 mA µA OUTPUT POWER 4 Ω, PVDD = 14.4V, THD+N ≤ 1%, 1 kHz, Tc = 75°C 4 Ω, PVDD = 14.4V, THD+N = 10%, 1 kHz, Tc = 75°C 23 25 4 Ω, PVDD = 14.4V, square wave, 1 kHz, Tc = 75°C 43 4 Ω, PVDD = 21 V, THD+N = 1%, 1 kHz, Tc = 75°C 4 Ω, PVDD = 21 V, THD+N = 10%, 1 kHz, Tc = 75°C POUT 47 50 2 Ω, PVDD = 14.4V, THD+N = 1%, 1 kHz, Tc = 75°C Output power per channel 2 Ω, PVDD = 14.4V, THD+N = 10%, 1 kHz, Tc = 75°C W 45 2 Ω, PVDD = 14.4 V, square wave 1 kHz, Tc = 75°C 70 PBTL 2-Ω operation, PVDD = 21 V, THD+N = 10%, 1 kHz, Tc = 75°C 116 90 4 channels operating, 23W output power/ch, L = 10 µH, TJ ≤ 85°C Power efficiency 58 38 40 PBTL 1-Ω operation, PVDD = 14.4 V, THD+N = 10%, 1 kHz, Tc = 75°C EFFP 28 90% AUDIO PERFORMANCE Noise voltage at output G = 26 dB, zero input, AES17 filter, and A-weighting Crosstalk Channel crosstalk 1W, G = 26 dB, 1 kHz 60 75 dB CMRR5424 Common-mode rejection ratio (TAS5424) 1 kHz, 1 Vrms referenced to SGND, G = 26 dB 60 75 dB PSRR Power supply rejection ratio G = 26 dB, PVDD = 14.4 Vdc + 1 Vrms, f = 1 kHz 60 75 THD+N Total harmonic distortion + noise P = 1 W, G = 26 dB, f = 1 kHz, 0°C ≤ TJ ≤ 75°C Switching frequency Switching frequency selectable for AM interference avoidance fS RAIN Analog input resistance Internal shunt resistance on each input pin VIN_CM Common-mode input voltage (non-clipping) AC-coupled common-mode input voltage (zero differential input) VCM_INT Internal common-mode input bias voltage Internal bias applied to IN_M pin G Voltage gain (VO/VIN) Source impedance = 0 Ω GCH Channel-to-channel variation Any gain commanded tCM Output-voltage common-mode ramping time tGAIN Gain ramping time 60 100 µV VNOISE dB 0.02% 0.1% 336 357 378 392 417 442 470 500 530 60 80 100 kΩ 1.3 Vrms 3.25 V 11 12 13 19 20 21 25 26 27 31 32 33 –1 0 1 External CMUTE = 330 nF kHz dB dB 35 ms 30 ms PWM OUTPUT STAGE RDSon FET Drain-to-source resistance Not including bond wire resistance, TJ = 25°C VO_OFFSET Output offset voltage Zero input signal and G = 26 dB 75 95 mΩ ±10 ±25 mV 23.7 26.3 V PVDD OVER VOLTAGE (OV) PROTECTION VOV PVDD over voltage shutdown 22.1 LOAD DUMP (LD) PROTECTION VLD_SD_SET Load-dump shutdown voltage 26.6 29 32 V VLD_SD_CLEAR Recovery voltage for load-dump shutdown 23.5 26.4 28.4 V PVDD UNDER VOLTAGE (UV) PROTECTION 8 VUV_SET PVDD under voltage shutdown 6.5 7 7.5 V VUV_CLEAR Recovery voltage for PVDD UV 7 7.5 8 V Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 ELECTRICAL CHARACTERISTICS (continued) Test conditions (unless otherwise noted): TCase = 25°C, PVDD = 14.4 V, RL = 4 Ω, fS = 417 kHz, Rext = 20 kΩ, master mode operation (see application diagram) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT AVDD VA_BYP A_BYP pin voltage 6.5 V VA_BYP_UV_SET A_BYP UV voltage 4.8 V VA_BYP_UV_CLEAR Recovery voltage A_BYP UV 5.3 V D_BYP pin voltage 3.3 V DVDD VD_BYP POWER-ON RESET (POR) VPOR Maximum PVDD voltage for POR; I2C active above this voltage VPOR_HY PVDD recovery hysteresis voltage for POR 6 V 0.1 V 1.24 V REXT VREXT Rext pin voltage CHARGE PUMP (CP) VCPUV_SET CP undervoltage 4.8 V VCPUV_CLEAR Recovery voltage for CP UV 5.2 V OVERTEMPERATURE (OV) PROTECTION TOTW1_CLEAR TOTW1_SET / TOTW2_CLEAR TOTW2_SET / TOTW3_CLEAR Junction temperature for overtemperature warning TOTW3_SET / TOTWD_CLEAR TOTSD Junction temperature for overtemperature shutdown 102 115 128 112 125 138 122 135 148 132 145 158 142 155 168 °C CURRENT LIMITING PROTECTION ILIM1 Current limit 1 (load current) Load < 4 Ω 5.5 7.3 9 A ILIM2 Current limit 2 (load current), I2C setting current limit level 2 Load < 2 Ω 8.5 11 13.5 A 9.5 11.3 13 A 11.5 14.3 17 A 325 540 750 mA OVERCURRENT (OC) SHUTDOWN PROTECTION IMAX1 Maximum current 1 (peak output current) IMAX2 Maximum current 2 (peak output current) Any short to supply, ground, or other channels TWEETER DETECT ITH_TW Load current threshold for tweeter detect ILIM_TW Load current limit for tweeter detect 2 A STANDBY MODE VIH_STBY STANDBY input voltage for logic-level high 2 5.5 VIL_STBY STANDBY input voltage for logic-level low 0 0.7 V ISTBY_PIN STANDBY pin current 0.2 µA 0.1 V MUTE MODE Output attenuation MUTE pin ≤ 0.9Vdc, VIN = 1 Vrms on all inputs VTH_DCD_POS DC detect positive threshold default value VTH_DCD_NEG DC detect negative threshold default value tDCD DC detect step response time for four channels GMUTE 85 dB PVDD = 14.4 Vdc, register 0x0E = 8EH 6.5 V PVDD = 14.4 Vdc, register 0x0F = 3DH –6.5 V DC DETECT 4.3 s CLIP_OTW REPORT VOH_CLIPOTW VOL_CLIPOTW CLIP_OTW pin output voltage for logic level high (open-drain logic output) CLIP_OTW pin output voltage for logic level low (open-drain logic output) 2.4 V External 47-kΩ pullup resistor to 3 V–5.5 V Submit Documentation Feedback 0.5 V 9 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 ELECTRICAL CHARACTERISTICS (continued) Test conditions (unless otherwise noted): TCase = 25°C, PVDD = 14.4 V, RL = 4 Ω, fS = 417 kHz, Rext = 20 kΩ, master mode operation (see application diagram) PARAMETER tDELAY_CLIPDET TEST CONDITIONS MIN TYP CLIP_OTW signal delay when output clipping detected MAX 20 UNIT µs FAULT REPORT VOH_FAULT VOL_FAULT FAULT pin output voltage for logic-level high (open-drain logic output) 2.4 FAULT pin output voltage for logic-level low (open-drain logic output) External 47-kΩ pullup resistor to 3 V–5.5 V V 0.5 OPEN/SHORT DIAGNOSTICS RS2P, RS2G Maximum resistance to detect a short from OUT pin(s) to PVDD or ground ROPEN_LOAD Minimum load resistance to detect open circuit Including speaker wires 300 RSHORTED_LOAD Maximum load resistance to detect short circuit Including speaker wires 0.5 Voltage on I2C_ADDR pin for address 0 Connect to SGND 0% 0% 15% Voltage on I2C_ADDR pin for address 1 External resistors in series between D_BYP and SGND as a voltage divider 25% 35% 45% Voltage on I2C_ADDR pin for address 2 55% 65% 75% Voltage on I2C_ADDR pin for address 3 Connect to D_BYP 85% 100% 100% tHOLD_I2C Power-on hold time before I2C communication STANDBY high fSCL SCL clock frequency VIH_SCL SCL pin input voltage for logic-level high VIL_SCL SCL pin input voltage for logic-level low 200 Ω 800 1300 Ω 1 1.5 Ω I2C ADDRESS DECODER tLATCH_I2CADDR VI2C_ADDR Time delay to latch I2C address after POR µs 300 VD_BYP I2C RPU_I2C = 5-kΩ pullup, supply voltage = 3.3 V or 5 V VOH_SDA SDA pin output voltage for logic-level high I2C read, RI2C = 5-kΩ pullup, supply voltage = 3.3 V or 5 V VOL_SDA SDA pin output voltage for logic-level low I2C read, 3-mA sink current VIH_SDA SDA pin input voltage for logic-level high I2C VIL_SDA SDA pin input voltage for logic-level low Ci Capacitance for SCL and SDA pins 1 ms 100 kHz 2.1 5.5 V –0.5 1.1 V 2.4 V 0 0.4 V write, RI2C = 5-kΩ pullup, supply voltage = 3.3 V or 5 V 2.1 5.5 V I2C write, RI2C = 5-kΩ pullup, supply voltage = 3.3 V or 5 V –0.5 1.1 V 10 pF 3.6 V 0.5 V 3.6 V 0.8 V OSCILLATOR VOH_OSCSYNC OSC_SYNC pin output voltage for logic-level high 2.4 I2C_ADDR pin set to MASTER mode VOL_OSCSYNC OSC_SYNC pin output voltage for logic-level low VIH_OSCSYNC OSC_SYNC pin input voltage for logic-level high VIL_OSCSYNC fOSC_SYNC 10 OSC_SYNC pin input voltage for logic-level low OSC_SYNC pin clock frequency 2 I2C_ADDR pin set to SLAVE mode I2C_ADDR pin set to MASTER mode, fS = 500 kHz, maximum capacitive loading = 5 pF 3.76 4.0 4.24 I2C_ADDR pin set to MASTER mode, fS = 417 kHz, maximum capacitive loading = 5 pF 3.13 3.33 3.63 I2C_ADDR pin set to MASTER mode, fS = 357 kHz, maximum capacitive loading = 5 pF 2.68 2.85 3.0 Submit Documentation Feedback MHz TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 TIMING REQUIREMENTS FOR I2C INTERFACE SIGNALS over recommended operating conditions (unless otherwise noted) MAX UNIT tr Rise time for both SDA and SCL signals PARAMETER 1000 ns tf Fall time for both SDA and SCL signals 300 ns tw(H) SCL pulse duration, high 4 µs tw(L) SCL pulse duration, low 4.7 µs tsu2 Setup time for START condition 4.7 µs th2 START condition hold time after which first clock pulse is generated 4 µs tsu1 Data setup time 250 ns th1 Data hold time 0 (1) ns tsu3 Setup time for STOP condition CB Load capacitance for each bus line (1) MIN TYP µs 4 400 pF A device must internally provide a hold time of at least 300 ns for the SDA signal to bridge the undefined region of the falling edge of SCL. tw(H) tw(L) tf tr SCL tsu1 th1 SDA T0027-01 Figure 1. SCL and SDA Timing SCL t(buf) th2 tsu2 tsu3 SDA Start Condition Stop Condition T0028-01 Figure 2. Timing for Start and Stop Conditions Submit Documentation Feedback 11 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 TYPICAL CHARACTERISTICS THD+N vs POWER at 1kHz THD+N vs FREQUENCY at 1 Watt 10 10 THD+N − Total Harmonic Distrotion + Noise − % THD+N − Total Harmonic Distrotion + Noise − % 100 21 VDC, 4 Ω 14.4 VDC, 4 Ω 1 14.4 VDC, 2 Ω 0.1 21 VDC, 2 Ω, PBTL 0.01 0.1 1 10 14.4 VDC, 2 Ω 14.4 VDC, 4 Ω 0.1 0.01 0.001 10 100 200 PO − Output Power − W 1 21 VDC, 4 Ω 100 Figure 4. COMMON-MODE REJECTION RATIO (TAS5424) CROSSTALK 0 −30 −20 −40 −40 Crosstalk − dBV −50 −60 −70 −60 −80 −100 −80 −90 10 −120 100 1k 10k 20k −140 10 100 1k 10k 20k f − Frequency − Hz f − Frequency − Hz G004 G003 Figure 5. 12 10k 20k G002 G001 Figure 3. CMRR − Common−Mode Rejection Ratio − dBV 1k f − Frequency − Hz Figure 6. Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 TYPICAL CHARACTERISTICS (continued) IMD SMPTE 19 kHz, 20 kHz 1:1 NOISE FFT −60 −70 −20 −80 −40 Voltage − dBV IMD SMPTE 19 kHz, 20 kHz 1:1 − dBV 0 −60 −90 −80 −100 −100 −110 −120 10 100 1k 10k −120 10 30k 100 f − Frequency − Hz 1k 10k 30k f − Frequency − Hz G005 G006 Figure 7. Figure 8. EFFICIENCY, FOUR CHANNELS AT 4 Ω EACH DEVICE POWER DISSIPATION FOUR CHANNELS INTO 4 Ω 100 12 90 10 80 Power Dissipation − W Efficiency − % 70 60 50 40 30 20 8 6 4 2 10 0 0 0 4 8 12 16 20 24 28 32 0 P − Power Per Channel − W G007 Figure 9. 5 10 15 20 P − Power Per Channel − W G008 Figure 10. Submit Documentation Feedback 13 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 TYPICAL CHARACTERISTICS (continued) DC DETECT VOLTAGE vs REGISTER 0E VALUES 20 18 16 DC Detect − V 14 PVDD = 20 V PVDD = 14.4 V 12 10 8 PVDD = 8 V 6 4 2 0 65 6a 6f 74 79 7e 83 88 8d 92 97 9c a1 Register 0E − Hex a6 ab b0 b5 ba bf c4 c9 G009 Figure 11. DC DETECT VOLTAGE vs REGISTER 0F VALUES 0 −2 −4 PVDD = 8 V DC Detect − V −6 −8 PVDD = 14.4 V −10 −12 −14 PVDD = 20 V −16 −18 −20 00 05 0a 0f 14 19 1e 23 28 2d 32 37 3c Register 0F − Hex 41 46 4b 50 55 5a 5f 64 G010 Figure 12. 14 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 DESCRIPTION OF OPERATION OVERVIEW The TAS5414 and TAS5424 are single-chip, four-channel, analog-input audio amplifiers for use in the automotive environment. The design uses an ultra-efficient class-D technology developed by Texas Instruments, but with changes needed by the automotive industry. This technology allows for reduced power consumption, reduced heat, and reduced peak currents in the electrical system. The TAS5414 and TAS5424 realize an audio sound system design with smaller size and lower weight than traditional class-AB solutions. The TAS5414 and TAS5424 are composed of eight elements: • Preamplifier • PWM • Gate drive • Power FETs • Diagnostics • Protection • Power supply • I2C serial communication bus Preamplifier The preamplifier of the TAS5414 and TAS5424 is a high-input-impedance, low-noise, low-offset-voltage input stage with adjustable gain. The high input impedance of the TAS5414 and TAS5424 allows the use of low-cost 1-µF input capacitors while still achieving extended low-frequency response. The preamplifier is powered by a dedicated, internally regulated supply, which gives it excellent noise immunity and channel separation. Also included in the preamp are: 1. Mute Pop-and-Click Control—An audio input signal is reshaped and amplified as a step when a mute is applied at the crest or trough of the signal. Such a step is perceived as a loud click. This is avoided in the TAS5414 and TAS5424 by ramping the gain gradually when a mute or play command is received. Another form of click and pop can be caused by the start or stopping of switching in a class-D amplifier. The TAS5414 and TAS5424 incorporate a patented method to reduce the pop energy during the switching startup and shutdown sequence. Fault conditions require rapid protection response by the TAS5414 and the TAS5424, which do not have time to ramp the gain down in a pop-free manner. The device transitions into Hi-Z mode when an OV, UV, OC, OT, or DC fault is encountered. Also, activation of the STANDBY pin may not be pop-free. 2. Gain Control—The four gain settings are set in the preamplifier via I2C control registers. The gain is set outside of the global feedback resistors of the TAS5414 and the TAS5424, thus allowing for stability in the system under all load conditions and gain settings. 3. DC Offset Reduction Circuitry—Circuitry has been incorporated to reduce the dc offset. DC offset in high-gain amplifiers can produce audible clicks and pops when the amplifier is started or stopped. The offset reduction circuitry can be disabled or enabled via I2C. Pulse-Width Modulator (PWM) The PWM converts the analog signal from the preamplifier into a switched signal of varying duty cycle. This is the critical stage that defines the class-D architecture. In the TAS5414 and TAS5424, the modulator is an advanced design with high bandwidth, low noise, low distortion, excellent stability, and full 0–100% modulation capability. The patented PWM uses clipping recovery circuitry to eliminate the deep saturation characteristic of PWMs when the input signal exceeds the modulator waveform. Gate Drive The gate driver accepts the low-voltage PWM signal and level shifts it to drive a high-current, full-bridge, power FET stage. The TAS5414 and TAS5424 use patent-pending techniques to avoid shoot-through and are optimized for EMI and audio performance. Submit Documentation Feedback 15 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 DESCRIPTION OF OPERATION (continued) Power FETs The BTL output for each channel comprises four rugged N-channel 30-V FETs, each of which has an RDSon of 75 mΩ for high efficiency and maximum power transfer to the load. These FETs are designed to handle large voltage transients during load dump. Load Diagnostics The TAS5414 and TAS5424 incorporate load diagnostic circuitry designed to help pinpoint the nature of output misconnections during installation. The TAS5414 and the TAS5424 include functions for detecting and determining the status of output connections. The following diagnostics are supported: • Short to GND • Short to PVDD • Short across load (R < 1 Ω, typical) • Open load (R > 800 Ω, typical) • Tweeter detection The presence of any of the short or open conditions is reported to the system via I2C register read. The tweeter detect status can be read from the CLIP_OTW pin when properly configured. 1. Output Short and Open Diagnostics—The TAS5414 and TAS5424 contain circuitry designed to detect shorts and open conditions on the outputs. The load diagnostic function can only be invoked when the output is in the Hi-Z mode. There are four phases of test during load diagnostics and two levels of test. In the full level, all channels must be in the Hi-Z state. All four phases are tested on each channel, all four channels at the same time. When fewer than four channels are in Hi-Z, the reduced level of test is the only available option. In the reduced level, only short to PVDD and short to GND can be tested. Load diagnostics can occur at power up before the amplifier is moved out of Hi-Z mode. If the amplifier is already in play mode, it must Mute and then Hi-Z before the load diagnostic can be performed. By performing the mute function, the normal pop- and click-free transitions occur before the diagnostics begin. The diagnostics are performed as shown in Figure 13. Figure 14 shows the impedance ranges for the open-load and shorted-load diagnostics. The results of the diagnostic are read from the diagnostic register for each channel via I2C. Note: Do not send a command via I2C to register 0x0C during the load diagnostic test. Hi-Z Channel Synchronization Playback / Mute OUT1P Phase1 Phase2 Phase3 Phase4 S2G S2P OL SL OUT1M VSpeaker (OUT1M–OUT1P) 100 ms ~50 ms ~50 ms ~50 ms ~50 ms 100 ms 150 ms ~50 ms ~50 ms ~50 ms ~50 ms 150 ms <100 ms T0188-01 Figure 13. Load Diagnostics Sequence of Events 16 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 DESCRIPTION OF OPERATION (continued) Short Detection Range Short Detected Open Detection Range Normal Load Detected Open Detected RLoad (Including Wires) 1.5 0.5 300 1 (Typ) 1300 800 (Typ) M0067-01 Figure 14. Open and Shorted Load Detection 2. Tweeter Detection—The tweeter detection function is an ac diagnostic used to determine proper connection of the tweeter when a passive crossover is used. The proper implementation of this diagnostic function is dependent on the amplitude of a user-supplied test signal and on the impedance vs frequency curve of the acoustic package. The tweeter function is invoked via I2C, and all four channels should be tested individually. The tweeter detection uses the average cycle-by-cycle current limit circuit (see CBC section) to measure the current to the load. The current level for the tweeter detection threshold is typically 550 mA. The system (external to the TAS5414 and TAS5424) must generate a tone burst in the 10-kHz to 25-kHz range. If the tone burst employs a frequency higher than 20 kHz, and if a sufficiently smooth amplitude ramp is used, the tweeter detection signal is silent. The frequency and amplitude of this tone burst must be calibrated by the user to result in a current draw greater than the selected threshold level when the tweeter is present. The tweeter detection results are monitored on the CLIP_OTW pin during the application of the test tone. If the current threshold is attained during measurement, the tweeter is present; then the CLIP_OTW pin is asserted. When the tweeter detector is activated, pulses on the CLIP_OTW pin begin to toggle at 250 kHz to 500 kHz. As the detection signal gets stronger due to higher load current, the density (or duty cycle) of the pulses increases. Protection and Monitoring 1. Cycle-By-Cycle Current Limit (CBC)—The CBC current-limiting circuit terminates each PWM pulse to limit the output current flow when the average current limit (ILIM) threshold is exceeded. The overall effect on the audio in the case of a current overload is quite similar to a voltage-clipping event, where power is temporarily limited at the peaks of the musical signal and normal operation continues without disruption when the overload is removed. The TAS5414 and TAS5424 do not prematurely shut down in this condition. All four channels continue in play mode and pass signal. 2. Overcurrent Shutdown (OCSD)—Under severe short-circuit events, such as a short to PVDD or ground, a peak-current detector is used, and the affected channel shuts down in 200 µs to 390 µs if the conditions are severe enough. The shutdown speed depends on a number of factors, such as the impedance of the short circuit, supply voltage, and switching frequency. Only the shorted channels are shut down in such a scenario. The user may restart the affected channel via I2C. An OCSD event activates the fault pin, and the affected channel(s) are recorded in the I2C fault register. If the supply or ground short is strong enough to exceed the peak current threshold but not severe enough to trigger the OCSD, the peak current limiter prevents excess current from damaging the output FETs, and operation returns to normal after the short is removed. 3. DC Detect—This circuit detects a dc offset continously during normal operation at the output of the Submit Documentation Feedback 17 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 DESCRIPTION OF OPERATION (continued) 4. 5. 6. 7. 18 amplifier. If the dc offset reaches the level defined in the I2C registers for the specified time period, the circuit triggers. By default a dc detection event does not shut the output down. The shutdown function can be enabled or disabled via I2C. If enabled, the triggered channel shuts down, but the others remain playing and the FAULT pin is asserted. The positive dc level and negative dc level are defined in I2C registers and can have separate thresholds. Clip Detect—The clip detect circuit alerts the user to the presence of a 100% duty-cycle PWM due to a clipped waveform. When this occurs, a signal is passed to the CLIP_OTW pin and it is asserted until the 100% duty-cycle PWM signal is no longer present. All four channels are connected to the same CLIP_OTW pin. Through I2C, the CLIP_OTW signal can be changed to clip-only, OTW-only, or both. A fourth mode, used only during diagnostics, is the option to report tweeter detection events on this pin (see the Tweeter Detection section). The microcontroller in the system can monitor the signal at the CLIP_OTW pin and may be configured to reduce the volume to all four channels in an active clipping-prevention circuit. Overtemperature Warning (OTW) and Overtemperature Shutdown (OTSD)—By default, the CLIP_OTW pin is set to indicate an OTW. This can be changed via I2C commands. If selected to indicate a temperature warning, the CLIP_OTW pin is asserted when the die temperature reaches 125°C. The OTW has three temperature thresholds with a 10°C hysteresis. Each threshold is indicated in I2C register 0x04 bits 5, 6, and 7. The TAS5414 and TAS5424 still function until the temperature reaches the OTSD threshold. 155°C, at which time the outputs are placed into Hi-Z mode and the FAULT pin is asserted. I2C is still active in the event of an OTSD and the registers can be read for faults, but all audio ceases abruptly. The OTSD resets at 145°C, to allow the TAS5414/5424 to be turned back on through I2C. The OTW is still indicated until the temperature drops below 115°C. All temperatures are nominal values. Undervoltage (UV) and Power-on-Reset (POR)—The undervoltage (UV) protection detects low voltages on PVDD, AVDD, and CP. In the event of an undervoltage, the FAULT pin is asserted and the I2C register is updated, depending on which voltage caused the event. Power-on-reset (POR) occurs when PVDD drops low enough. A POR event causes the I2C to go into a high-impedance state. After the device recovers from the POR event, the device must be re-initialized via I2C. Overvoltage (OV) and Load Dump—The OV protection detects high voltages on PVDD. If PVDD reaches the overvoltage threshold, the FAULT pin is asserted and the I2C register is updated. If the voltage increases beyond the load dump threshold of 29 Vdc, the device shuts down and must be restarted once the voltage returns to a safe value. After the device recovers from the ≈ load dump event, the device must be re-initialized via I2C. The TAS5414 and TAS5424 can withstand 50-V load-dump voltage spikes (see Figure 15). Also depicted in this graph are the voltage thresholds for normal operation region, overvoltage operation region, and load-dump protection region. Figure 13 shows the regions of operating voltage and the profile of the load dump event. Battery charger voltages from 25 V to 35 V can be withstood for up to 1 hour. Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 DESCRIPTION OF OPERATION (continued) PVDD 50 V 100 ms Max 50 V Max Ramp Rate 25 V/ms Load Dump Protection 29 V–50 V 2 I C Stop Standby Mode POR 2 I C Start 29 V Overvoltage Protection Region 23 V–29 V 26 V 23 V 22 V Hi-Z All Ch’s 14.4 V Normal Operating Region 8 V–22 V Ready to Get Off Hi-Z State Time T0189-01 Figure 15. Voltage Operating Regions With Load Dump Transition Defined Power Supply The power for the device is most commonly provided by a car battery that can have a large voltage swing, 8 Vdc to 18 Vdc. PVDD is a filtered battery voltage, and it is the supply for the output FETS and the low-side FET gate driver. The high-side FET gate driver is supplied by a charge pump (CP) supply. The charge pump supplies the gate drive voltage for all four channels. The analog circuitry is powered by AVDD, which is a provided by an internal linear regulator. A 0.1µF/10V external bypass capacitor is needed at the A_BYP pin for this supply. It is recommended that no external components except the bypass capacitor be attached to this pin. The digital circuitry is powered by DVDD, which is provided by an internal linear regulator. A 0.1µF/10V external bypass capacitor is needed at the D_BYP pin. It is recommended that no external components except the bypass capacitor be attached to this pin. The TAS5414 and TAS5424 can withstand fortuitous open ground and power conditions. Fortuitous open ground usually occurs when a speaker wire is shorted to ground, allowing for a second ground path through the body diode in the output FETs. The uniqueness of the diagnostic capabilities allows the speakers and speaker wires to be debugged, eliminating the need to remove the amplifier to diagnose the problem. I2C Serial Communication Bus The TAS5414 and TAS5424 communicate with the system processor via the I2C serial communication bus. The TAS5414 and TAS5424 are I2C slave-only devices. The processor can poll the TAS5414 and the TAS5424 via I2C to determine the operating status of the device. All fault conditions and detections are reported via I2C. There are also numerous features and operating conditions that can be set via I2C. The I2C bus allows control of the following configurations: • Independent gain control of each channel. The gain can be set to 12 dB, 20 dB, 26 dB, and 32 dB. Submit Documentation Feedback 19 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 DESCRIPTION OF OPERATION (continued) • • • • • • • • Select current limit (for 2-Ω and for 4-Ω loads). This allows optimal design of the filter inductor, and the use of smaller gauge speaker wires for 4-Ω applications. Select AM non-interference switching frequency Select the function of OTW_CLIP pin Enable or disable dc detect function with selectable threshold Place channel in Hi-Z (switching stopped) mode (mute) Select tweeter detect, set detect threshold and initiate function Initiate open/short load diagnostic Reset faults and return to normal switching operation from Hi-Z mode (unmute) In addition to the standard SDA and SCL pins for the I2C bus, the TAS5414 and the TAS5424 include a single pin that allows up to four devices to work together in a system with no additional hardware required for communication or synchronization. The I2C_ADDR pin sets the device in master or slave mode and selects the I2C address for that device. Tie I2C_ADDR to DGND for master, to 1.2 Vdc for slave 1, to 2.4 Vdc for slave 2, and to D_BYP for slave 3. The OSC_SYNC pin is used to synchronize the internal clock oscillators and thereby avoid beat frequencies. An external oscillator can also be applied to this pin for external control of the switching frequency. Table 2. Table 7. I2C_ADDR Pin Connection DESCRIPTION TAS5414/5424 0 (OSC MASTER) I2C ADDRESS I2C_ADDR PIN CONNECTION To SGND pin 0xD8/D9 TAS5414/5424 1 (OSC SLAVE1) 35% DVDD (resistive voltage divider between D_BYP pin and SGND pin) (1) 0xDA/DB TAS5414/5424 2 (OSC SLAVE2) 65% DVDD (resistive voltage divider between D_BYP pin and SGND pin) (1) 0xDC/DD TAS5414/5424 3 (OSC SLAVE3) To D_BYP pin 0xDE/DF (1) RI2C_ADDR with 5% or better tolerance is recommended. I2C Bus Protocol The TAS5414 and TAS5424 have a bidirectional serial control interface that is compatible with the Inter IC (I2C) bus protocol and supports 100-kbps data transfer rates for random and sequential write and read operations. This is a slave-only device that does not support a multimaster bus environment or wait state insertion. The control interface is used to program the registers of the device and to read device status. The I2C bus employs two signals, SDA (data) and SCL (clock), to communicate between integrated circuits in a system. Data is transferred on the bus serially, one bit at a time. The address and data are transferred in byte (8-bit) format with the most-significant bit (MSB) transferred first. In addition, each byte transferred on the bus is acknowledged by the receiving device with an acknowledge bit. Each transfer operation begins with the master device driving a start condition on the bus and ends with the master device driving a stop condition on the bus. The bus uses transitions on the data terminal (SDA) while the clock is HIGH to indicate a start and stop conditions. A HIGH-to-LOW transition on SDA indicates a start, and a LOW-to-HIGH transition indicates a stop. Normal data bit transitions must occur within the low time of the clock period. These conditions are shown in Figure 16. The master generates the 7-bit slave address and the read/write (R/W) bit to open communication with another device and then wait for an acknowledge condition. The TAS5414 and TAS5424 hold SDA LOW during the acknowledge-clock period to indicate an acknowledgement. When this occurs, the master transmits the next byte of the sequence. Each device is addressed by a unique 7-bit slave address plus R/W bit (1 byte). All compatible devices share the same signals via a bidirectional bus using a wired-AND connection. An external pullup resistor must be used for the SDA and SCL signals to set the HIGH level for the bus. There is no limit on the number of bytes that can be transmitted between start and stop conditions. When the last word transfers, the master generates a stop condition to release the bus. 20 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 SDA R/ A W 7-Bit Slave Address 7 5 6 4 3 2 1 8-Bit Register Address (N) 7 0 5 6 3 4 2 1 8-Bit Register Data For Address (N) A 0 7 6 5 4 3 2 1 8-Bit Register Data For Address (N) A 7 0 6 5 4 3 2 1 A 0 SCL Start Stop T0035-01 Figure 16. Typical I2C Sequence Use the I2C_ADDR pin (pin 2) to program licensed I2C addresses and do not conflict TAS5414 and the TAS5424, the I2C master transmitted using single-byte or multiple-byte the device for one of four addresses. These four addresses are with other licensed I2C audio devices. To communicate with the uses addresses shown in Figure 16. Read and write data can be data transfers. Random Write As shown in Figure 17, a single-byte data-write transfer begins with the master device transmitting a start condition followed by the I2C device address and the read/write bit. The read/write bit determines the direction of the data transfer. For a write data transfer, the read/write bit is a 0. After receiving the correct I2C device address and the read/write bit, the TAS5414 or TAS5424 device responds with an acknowledge bit. Next, the master transmits the address byte or bytes corresponding to the internal memory address being accessed. After receiving the address byte, the TAS5414 or TAS5424 again responds with an acknowledge bit. Next, the master device transmits the data byte to be written to the memory address being accessed. After receiving the data byte, the TAS5414 or TAS5424 again responds with an acknowledge bit. Finally, the master device transmits a stop condition to complete the single-byte data-write transfer. Start Condition Acknowledge A6 A5 A4 A3 A2 A1 A0 Acknowledge R/W ACK A7 A6 A5 2 A4 A3 A2 A1 Acknowledge A0 ACK D7 D6 Subaddress I C Device Address and Read/Write Bit D5 D4 D3 D2 D1 D0 ACK Stop Condition Data Byte T0036-01 Figure 17. Random Write Transfer Sequential Write A sequential data-write transfer is identical to a single-byte data-write transfer except that multiple data bytes are transmitted by the master device to TAS5414 or TAS5424 as shown in Figure 17. After receiving each data byte, the TAS5414 or TAS5424 responds with an acknowledge bit and the I2C subaddress is automatically incremented by one. Start Condition Acknowledge A6 A5 2 A1 A0 R/W ACK A7 I C Device Address and Read/Write Bit A6 A5 A4 A3 Subaddress A1 Acknowledge Acknowledge Acknowledge Acknowledge A0 ACK D7 D0 ACK D7 D0 ACK D7 D0 ACK First Data Byte Other Data Bytes Last Data Byte Stop Condition T0036-02 Figure 18. Sequential Write Transfer Submit Documentation Feedback 21 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Random Read As shown in Figure 19, a single-byte data-read transfer begins with the master device transmitting a start condition followed by the I2C device address and the read/write bit. For the data-read transfer, both a write followed by a read are actually done. Initially, a write is done to transfer the address byte or bytes of the internal memory address to be read. As a result, the read/write bit is a 0. After receiving the address and the read/write bit, the TAS5414 or TAS5424 responds with an acknowledge bit. In addition, after sending the internal memory address byte or bytes, the master device transmits another start condition followed by the TAS5414 or TAS5424 address and the read/write bit again. This time the read/write bit is a 1, indicating a read transfer. After receiving the address and the read/write bit, the TAS5414 or TAS5424 again responds with an acknowledge bit. Next, the TAS5414 or TAS5424 transmits the data byte from the memory address being read. After receiving the data byte, the master device transmits a not-acknowledge followed by a stop condition to complete the single-byte data-read transfer. Repeat Start Condition Start Condition Acknowledge A6 A5 A1 A0 R/W ACK A7 Acknowledge A6 2 A5 A4 A0 ACK A6 A5 A1 A0 R/W ACK D7 D6 2 Subaddress I C Device Address and Read/Write Bit Not Acknowledge Acknowledge D1 D0 ACK Stop Condition Data Byte I C Device Address and Read/Write Bit T0036-03 Figure 19. Random Read Transfer Sequential Read A sequential data-read transfer is identical to a single-byte data-read transfer except that multiple data bytes are transmitted by the TAS5414 or TAS5424 to the master device as shown in Figure 20. Except for the last data byte, the master device responds with an acknowledge bit after receiving each data byte and automatically increments the I2C subaddress by one. Note: The fault registers do not have sequential read capabilities. Repeat Start Condition Start Condition Acknowledge A6 2 A0 R/W ACK A7 I C Device Address and Read/Write Bit Acknowledge A6 A5 Subaddress A0 ACK A6 2 Acknowledge Acknowledge Acknowledge Not Acknowledge A0 R/W ACK D7 D0 ACK D7 D0 ACK D7 D0 ACK I C Device Address and Read/Write Bit First Data Byte Other Data Bytes Last Data Byte Stop Condition T0036-04 Figure 20. Sequential Read Transfer 22 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 2 Table 3. TAS5414/5424 I C Addresses SELECTABLE WITH ADDRESS PIN FIXED ADDRESS DESCRIPTION READ/WRITE BIT I2C ADDRESS MSB 6 5 4 3 2 1 LSB TAS5414/5424 0 (OSC MASTER) I2C WRITE 1 1 0 1 1 0 0 0 0xD8 I2C READ 1 1 0 1 1 0 0 1 0xD9 TAS5414/5424 1 (OSC SLAVE1) I2C 1 1 0 1 1 0 1 0 0xDA I2C READ 1 1 0 1 1 0 1 1 0xDB TAS5414/5424 2 (OSC SLAVE2) I2C WRITE 1 1 0 1 1 1 0 0 0xDC I2C READ 1 1 0 1 1 1 0 1 0xDD TAS5414/5424 3 (OSC SLAVE3) I2C WRITE 1 1 0 1 1 1 1 0 0xDE I2C READ 1 1 0 1 1 1 1 1 0xDF WRITE Table 4. I2C Address Register Definitions ADDRESS R/W REGISTER DESCRIPTION 0x00 R Latched fault register 1, global and channel fault 0x01 R Latched fault register 2, dc offset and overcurrent detect 0x02 R Latched fault register 3, load diagnostics 0x03 R Latched fault register 4, load diagnostics 0x04 R External status register 1, temperature and voltage detect 0x05 R External status register 2, Hi-Z and low-low state 0x06 R External status register 3, mute and play modes 0x07 R External status register 4, load diagnostics 0x08 R/W External control register 1, channel gain select 0x09 R/W External control register 2, dc offset reduction and current-limit select 0x0A R/W External control register 3, switching frequency and clip pin select 0x0B R/W External control register 4, load diagnostic, master mode select 0x0C R/W External control register 5, output state control 0x0D R/W External control register 6, output state control 0x0E R/W External control register 7, dc detect level select 0x0F R/W External control register 8, dc detect level select Table 5. Fault Register 1 (0x00) Protection D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 0 0 0 0 0 No protection-created faults, default value FUNCTION – – – – – – – 1 Overtemperature warning has occurred – – – – – – 1 – DC offset has occurred in any channel – – – – – 1 – – Overcurrent shutdown has occurred in any channel – – – – 1 – – – Overtemperature shutdown has occurred – – – 1 – – – – Charge pump undervoltage has occurred – – 1 – – – – – AVDD, analog voltage, undervoltage has occurred – 1 – – – – – – PVDD undervoltage has occurred 1 – – – – – – – PVDD overvoltage has occurred Table 6. Fault Register 2 (0x01) Protection D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 0 0 0 0 0 No protection-created faults, default value FUNCTION – – – – – – – 1 Ovecurrent shutdown channel 1 has occurred – – – – – – 1 – Overcurrent shutdown channel 2 has occurred Submit Documentation Feedback 23 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Table 6. Fault Register 2 (0x01) Protection (continued) D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION – – – – – 1 – – Overcurrent shutdown channel 3 has occurred – – – – 1 – – – Overcurrent shutdown channel 4 has occurred – – – 1 – – – – DC offset channel 1 has occurred – – 1 – – – – – DC offset channel 2 has occurred – 1 – – – – – – DC offset channel 3 has occurred 1 – – – – – – – DC offset channel 4 has occurred Table 7. Fault Register 3 (0x02) Load Diagnostics D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 0 0 0 0 0 No load-diagnostic-created faults, default value FUNCTION – – – – – – – 1 Output short to ground channel 1 has occurred – – – – – – 1 – Output short to PVDD channel 1 has occurred – – – – – 1 – – Shorted load channel 1 has occurred – – – – 1 – – – Open load channel 1 has occurred – – – 1 – – – – Output short to ground channel 2 has occurred – – 1 – – – – – Output short to PVDD channel 2 has occurred – 1 – – – – – – Shorted load channel 2 has occurred 1 – – – – – – – Open load channel 2 has occurred Table 8. Fault Register 4 (0x03) Load Diagnostics D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 0 0 0 0 0 No load-diagnostic-created faults, default value FUNCTION – – – – – – – 1 Output short to ground channel 3 has occurred – – – – – – 1 – Output short to PVDD channel 3 has occurred – – – – – 1 – – Shorted load channel 3 has occurred – – – – 1 – – – Open load channel 3 has occurred – – – 1 – – – – Output short to ground channel 4 has occurred – – 1 – – – – – Output short to PVDD channel 4 has occurred – 1 – – – – – – Shorted load channel 4 has occurred 1 – – – – – – – Open load channel 4 has occurred Table 9. External Status Register 1 (0x04) Fault Detection 24 D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 0 0 0 0 0 No protection-created faults are present, default value FUNCTION – – – – – – – 1 PVDD overvoltage fault is present – – – – – – 1 – PVDD undervoltage fault is present – – – – – 1 – – AVDD, analog voltage fault is present – – – – 1 – – – Charge-pump voltage fault is present – – – 1 – – – – Overtemperature shutdown is present – – 1 – – – – – Overtemperature warning – 1 1 – – – – – Overtemperature warning level 1 1 0 1 – – – – – Overtemperature warning level 2 1 1 1 – – – – – Overtemperature warning level 3 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Table 10. External Status Register 2 (0x05) Output State of Individual Channels D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 0 1 1 1 1 Output is in Hi-Z mode, not in low-low mode(1), default value – – – – – – – 0 Channel 1 Hi-Z mode (0 = not Hi-Z, 1 = Hi-Z) – – – – – – 0 – Channel 2 Hi-Z mode (0 = not Hi-Z, 1 = Hi-Z) – – – – – 0 – – Channel 3 Hi-Z mode (0 = not Hi-Z, 1 = Hi-Z) – – – – 0 – – – Channel 4 Hi-Z mode (0 = not Hi-Z, 1 = Hi-Z) – – – 1 – – – – Channel 1 low-low mode (0 = not low-low, 1 = low-low) (1) – – 1 – – – – – Channel 2 low-low mode (0 = not low-low, 1 = low-low)(1) – 1 – – – – – – Channel 3 low-low mode (0 = not low-low, 1 = low-low)(1) 1 – – – – – – – Channel 4 low-low mode (0 = not low-low, 1 = low-low)(1) (1) FUNCTION Low-low is defined as both outputs actively pulled to ground. Table 11. External Status Register 3 (0x06) Play and Mute Modes D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 0 0 0 0 0 0 0 0 Mute mode is enabled, play mode disabled, default value – – – – – – – 1 Channel 1 play mode is enabled – – – – – – 1 – Channel 2 play mode is enabled – – – – – 1 – – Channel 3 play mode is enabled – – – – 1 – – – Channel 4 play mode is enabled – – – 1 – – – – Channel 1 mute mode is disabled – – 1 – – – – – Channel 2 mute mode is disabled – 1 – – – – – – Channel 3 mute mode is disabled 1 – – – – – – – Channel 4 mute mode is disabled D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 0 0 0 0 0 No channels are set in load diagnostics mode, default value – – – – – – – 1 Channel 1 is in load diagnostics mode – – – – – – 1 – Channel 2 is in load diagnostics mode – – – – – 1 – – Channel 3 is in load diagnostics mode – – – – 1 – – – Channel 4 is in load diagnostics mode X X X X – – – – Reserved Table 12. External Status Register 4 (0x07) Load Diagnostics FUNCTION Table 13. External Control Register 1 (0x08) Gain Select D7 D6 D5 D4 D3 D2 D1 D0 1 0 1 0 1 0 1 0 Set gain for all channels to 26 dB, default value FUNCTION – – – – – – 0 0 Set channel 1 gain to 12 dB – – – – – – 0 1 Set channel 1 gain to 20 dB – – – – – – 1 1 Set channel 1 gain to 32 dB – – – – 0 0 – – Set channel 2 gain to 12 dB – – – – 0 1 – – Set channel 2 gain to 20 dB – – – – 1 1 – – Set channel 2 gain to 32 dB – – 0 0 – – – – Set channel 3 gain to 12 dB – – 0 1 – – – – Set channel 3 gain to 20 dB – – 1 1 – – – – Set channel 3 gain to 32 dB 0 0 – – – – – – Set channel 4 gain to 12 dB 0 1 – – – – – – Set channel 4 gain to 20 dB 1 1 – – – – – – Set channel 4 gain to 32 dB Submit Documentation Feedback 25 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Table 14. External Control Register 2 (0x09) DC Offset Reduction and Current Limit D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 0 0 0 0 0 0 0 0 Enable dc offset reduction, set current limit to level 1 – – – – – – – 1 Disable channel 1 dc offset reduction – – – – – – 1 – Disable channel 2 dc offset reduction – – – – – 1 – – Disable channel 3 dc offset reduction – – – – 1 – – – Disable channel 4 dc offset reduction – – – 1 – – – – Set channel 1 current limit (0 = level 1, 1 = level 2) – – 1 – – – – – Set channel 2 current limit (0 = level 1, 1 = level 2) – 1 – – – – – – Set channel 3 current limit (0 = level 1, 1 = level 2) 1 – – – – – – – Set channel 4 current limit (0 = level 1, 1 = level 2) Table 15. External Control Register 3 (0x0A) Switching Frequency Select and Clip_OTW Configuration D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 0 0 0 0 1 1 0 1 Set fS = 417 kHz, configure clip and OTW, 45° phase, disable hard stop – – – – – – 0 0 Set fS = 500 kHz – – – – – – 1 0 Set fS = 357 kHz – – – – – – 1 1 Invalid frequency selection (do not set) – – – – 0 0 – – Configure CLIP_OTW pin for tweeter detect only – – – – 0 1 – – Configure CLIP_OTW pin for clip detect only – – – – 1 0 – – Configure CLIP_OTW pin for overtemperature warning only – – – 1 – – – – Enable hard-stop mode – – 1 – – – – – Set fS to a 90° phase difference between adjacent channels X X – – – – – – Reserved Table 16. External Control Register 4 (0x0B) Load Diagnostics and Master/Slave Control D7 D6 D5 D4 D3 D2 D1 D0 0 1 0 0 0 0 0 0 Disable load diagnostics and dc detect SD, master mode FUNCTION – – – – – – – 1 Enable channel 1, load diagnostics – – – – – – 1 – Enable channel 2, load diagnostics – – – – – 1 – – Enable channel 3, load diagnostics – – – – 1 – – – Enable channel 4, load diagnostics – – – 1 – – – – Enable dc detect shutdown on all channels – – 1 – – – – – Enable tweeter-detect mode – 0 – – – – – – Enable slave mode (external oscillator must be provided) X – – – – – – – Reserved Table 17. External Control Register 5 (0x0C) Output Control 26 D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 1 1 1 1 1 All channels, Hi-Z, mute, reset disabled FUNCTION – – – – – – – 0 Set channel 1 to mute mode, non-Hi-Z – – – – – – 0 – Set channel 2 to mute mode, non-Hi-Z – – – – – 0 – – Set channel 3 to mute mode, non-Hi-Z – – – – 0 – – – Set channel 4 to mute mode, non-Hi-Z – – – 0 – – – – Set non-Hi-Z channels to play mode, (unmute) – 1 1 – – – – – Reserved 1 – – – – – – – Reset device (I2C does not respond with an ACK) Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Table 18. External Control Register 6 (0x0D) Output Control D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 0 0 0 0 0 0 0 0 Low-low state disabled all channels – – – – – – – 1 Set channel 1 to low-low state – – – – – – 1 – Set channel 2 to low-low state – – – – – 1 – – Set channel 3 to low-low state – – – – 1 – – – Set channel 4 to low-low state X X X X – – – – Reserved Table 19. External Control Register 7 (0x0E) Positive DC Detect Threshold Selection D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 1 0 0 0 1 1 1 0 Default positive dc detect value 0 1 1 0 0 1 0 1 Minimum positive dc detect value X X X X X X X X See Figure 11 to set positive dc detect value 1 1 0 0 1 0 1 1 Maximum positive dc detect value Table 20. External Control Register 8 (0x0F) Negative DC Detect Threshold Selection D7 D6 D5 D4 D3 D2 D1 D0 0 0 1 1 1 1 0 1 Default negative dc detect value FUNCTION 0 1 1 0 0 1 0 1 Minimum negative dc detect value X X X X X X X X See Figure 12 to set negative dc detect value 0 0 0 0 0 0 0 0 Maximum negative dc detect value Hardware Control Pins The TAS5414 and TAS5424 incorporate four discrete hardware pins for real-time control and indication of device status. FAULT pin: This active-low, open-drain output pin indicates the presence of a fault condition that requires the TAS5414 and TAS5424 to go automatically into the Hi-Z mode or standby mode. When this pin is asserted high, the device has acted to protect itself and the system from potential damage. The exact nature of the fault can be read via I2C with the exception of faults that are the result of PVDD voltage excursions above 25 Vdc or below 5.5 Vdc. In these instances, the device goes into standby mode and the I2C bus is no longer operational. However, the fault is still indicated due to the fact that the FAULT pin is open-drain and active-high. CLIP_OTW pin: The function of this active-high pin is configured by the user to indicate one of the following conditions: overtemperature warning, the detection of clipping, or the logical OR of both of these conditions. The configuration is selected via I2C. During tweeter detect diagnostics, this pin also is asserted when a tweeter is present. MUTE pin: This active-low pin is used for hardware control of the mute/unmute function for all four channels. Capacitor CMUTE is used to control the time constant for the gain ramp needed to produce a pop- and click-free mute function. For pop- and click-free operation, the mute function should be implemented through I2C commands. The use of a hard mute with an external transistor does not ensure pop- and click-free operation, and is not recommended unless an emergency hard mute function is required in case of a loss of I2C control. The value of CMUTE must be 330 nF for proper pop- and click-free operation. STANDBY pin: When this active-low pin is asserted, the device goes into a complete shutdown, and current draw is limited to 2 µA, typical. This is pin typically asserted when the car ignition is in the off position. It can also be used to shut down the device rapidly when certain operating conditions are violated. All I2C register content is lost when this pin is asserted. The I2C bus goes into the high-impedance state when the STANDBY pin is asserted. Submit Documentation Feedback 27 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 EMI Considerations Automotive level EMI performance depends on both careful integrated circuit design and good system level design. Controlling sources of electromagnetic interference (EMI) was a major consideration in all aspects of the TAS5414 and TAS5424 design. The TAS5414 and TAS5424 have minimal parasitic inductances due to the short leads on the PSOP3 package. This dramatically reduces the EMI that results from current passing from the die to the system PCB. Each channel of the TAS5414 and TAS5424 also operates at a different phase. The phase between channels is I2C selectable to either 45° or 90°, to reduce EMI caused by high-current switching. The TAS5414 and TAS5424 incorporate patent-pending circuitry that optimizes output transitions that cause EMI. AM Radio EMI Reduction To reduce interference in the AM radio band, the TAS5414 and TAS5424 have the ability to change the switching frequency via I2C commands. The recommended frequencies are listed in Table 21. The fundamental frequency and its second harmonic straddle the AM radio band listed. This eliminates the tones that can be present due to the switching frequency being demodulated by the AM radio. To function properly, AM avoidance requires the use of a 20-kΩ, 1% tolerance Rext resistor. Table 21. Recommended Switching Frequencies for AM Mode Operation US EUROPEAN AM FREQUENCY (kHz) SWITCHING FREQUENCY (kHz) AM FREQUENCY (kHz) SWITCHING FREQUENCY (kHz) 522-540 417 540–917 500 540–914 500 917–1125 417 914–1122 417 1125–1375 500 1122–1373 500 1375–1547 417 1373–1548 417 1547–1700 357 1548–1701 357 Operating States The operating regions, or states, of the TAS5414 and TAS5424 are depicted in the following tables. Table 22. Operating States and Supplies OUTPUT FETS CHARGE PUMP OSCILLATOR I2C AVDD and DVDD STANDBY Hi-Z, floating Stopped Stopped Stopped OFF Hi-Z Hi-Z, weak pulldown Active Active Active ON Mute Switching at 50% Active Active Active ON Normal operation Switching with audio Active Active Active ON STATE NAME Table 23. Global Faults and Actions FAULT/ EVENT FAULT/EVENT CATEGORY POR Voltage fault UV REPORTING METHOD ACTION TYPE ACTION RESULT LATCHED/ SELFCLEARING All FAULT pin Hard mute (no ramp) Standby Self-clearing Hi-Z, mute, normal I2C + FAULT pin MONITORING MODES Hi-Z CP UV Hi-Z OV Hi-Z Load dump OTW OT 28 Thermal warning Thermal fault All FAULT pin Hi-Z, mute, normal I2C + CLIP_OTW pin Hi-Z, mute, normal I2C + FAULT pin Submit Documentation Feedback Standby None None Self-clearing Hard mute Standby Self-clearing TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Table 24. Channel Faults and Actions FAULT/ EVENT FAULT/EVENT CATEGORY MONITORING MODES REPORTING METHOD ACTION TYPE ACTION RESULT LATCHED/ SELFCLEARING Open/short diagnostic Diagnostic Hi-Z (I2C activated) I2C None None Latched Clipping online Warning Normal CLIP_OTW pin None None Self-clearing CBC load current limit Online protection Mute, normal CLIP_OTW pin Current limit Start OC timer Self-clearing OC fault Output channel fault Mute, normal I2C + FAULT pin Hard mute Hi-Z Latched I2C Hard mute Hi-Z Latched DC detect Normal + FAULT pin Min Rise Time 29 V to 50 V: 1 ms 50 V Load Dump Protection 29 V – 50 V LD Detect 29 V 23 V OV Detect OV Protection Region 23 V – 29 V 22 V Normal Operating Region 8 V – 22 V PVDD FAULT I2C CLK Hard Stop 15 V OUTM (Filtered) 15 V Time t0 t1 t2 Outputs OV Deglitch Pulled Down Time T0190-01 Figure 21. Sequence of Events for Supply Transition Out of Normal Operating Region Submit Documentation Feedback 29 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 50 V Load Dump Protection 29 V–50 V LD Reset 26 V OV Protection Region 23 V–29 V OV Reset 23 V PVDD Fault Does Not Reset Until Fault Register 1 Is Read FAULT 2 IC CLK Ready to Get Out of Hi-Z State 15-V OUTP or OUTM (Filtered) Time t0 t1 Oscillator Start-Up Time Outputs Pulled Down t2 t3 OV Deglitch Time T0191-01 Figure 22. Sequence of Events for Supply Transition Back Into Normal Operating Region 30 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Power Shutdown and Restart Sequence Control tGAIN tCM tCM tGAIN HIZ_CTLx (All Channels) 2 LOW_LOW_CTLx (All Channels) Internal I C Reset When HIZ_CTLx = 1 MUTE_CTLx (All Channels) MUTE Pin OUTx_P (Filtered) (All Channels) OUTx_M (Filtered) (All Channels) HIZ_MODx LOW_LOW_MODx PLAY_MODx MUTE_MODx T0192-01 Figure 23. Click- and Pop-Free Shutdown and Restart Sequence Timing Diagram With Four Channels Sharing the Mute Pin Submit Documentation Feedback 31 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 tGAIN tCM tCM tGAIN HIZ_CTL1 HIZ_CTL2,3,4 2 Internal I C Reset When HIZ_CTL1 = 1 LOW_LOW_CTL1 2 Internal I C Reset When When HIZ_CTL2,3,4 = 1 LOW_LOW_CTL2,3,4 MUTE_CTL MUTE Pin OUT1_P (Filtered) "Pop" "Pop" OUT2,3,4_P (Filtered) T0193-01 Figure 24. Individual Channel Shutdown and Restart Sequence Timing Diagram 32 Submit Documentation Feedback TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 Latched Fault Shutdown and Restart Sequence Control tI2C_CL tDEGLITCH tDEGLITCH PVDD VUV + VUV_HY UV Detect tGAIN UV Reset tCM PVDD Normal Operating Region PVDD UV Hysteresis Region VUV VPOR HIZ_CTLx 2 Internal I C Write MUTE_CTL UV_DET Cleared by 2 UV_LATCH External I C Read to Fault Register 1 2 External I C Read FAULT Pin MUTE Pin OUTx_P (Filtered) “Pop” T0194-01 Figure 25. Latched Global Fault Shutdown and Restart Timing Diagram (UV Shutdown and Recovery) Submit Documentation Feedback 33 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 tI2C_CL tDEGLITCH tDEGLITCH PVDD VUV + VUV_HY UV Detect tCM UV Reset tGAIN PVDD Normal Operating Region PVDD UV Hysteresis Region VUV VPOR 2 HIZ_CTL1 Internal I C Write HIZ_CTL2,3,4 MUTE_CTL UV_DET Cleared by 2 UV_LATCH External I C Read to Fault Register 1 2 External I C Read FAULT Pin MUTE Pin OUT1_P (Filtered) OUT2,3,4_P (Filtered) “Pop” “Pop” “Pop” T0195-01 Figure 26. Latched Global Fault Shutdown and Individual Channel Restart Timing Diagram (UV Shutdown and Recovery) 34 Submit Documentation Feedback Submit Documentation Feedback GND System Microprocessor 9 6 RLV RRV VSSA2 10 FRV 13 FLV 16 VREFDA Optional 4.7uF RC Filter RC Filter 12 11 10 9 8 7 1uF 1uF 1uF 1uF 1uF 18 17 16 15 14 100nF 13 20kW 1% 100nF RC Filter RC Filter 330nF 6 5 4 3 2 1 IN4_P IN3_P IN_M IN2_P IN1_P A_BYP REXT SGND GND CLIP_OTW D_ BYP STANDBY MUTE FAULT SCL SDA I2C_ ADDR Reverse Battery Protection PVDD PVDD OUT4_P OUT4_M PGND OUT3_P OUT3_M PGND CPC_ BOT CP CPC_ TOP OUT2_P OUT2_M PGND OUT1_P OUT1_M PVDD PVDD 19 20 21 22 23 24 25 26 27 28 29 5.6W 5.6W 5.6W 5.6W 30 5.6W 31 5.6W 32 33 5.6W 34 5.6W 35 36 Vehicle Negative Lead (Gnd) OSC_ SYNC VBATT 8V–22V "0": V0 (to SGND) (OSC Master Default) "1": V1 (OSC Slave 1) "2": V2 (OSC Slave 2) "3": V3 (to D_BYP) (OSC Slave 3) 3.3V–5V FAST MUTE PGND Radio DSP SGND Pull-up Resistors Ground Plane Additional TAS5414 Sync Additional TAS5414 Sync Additional TAS5414 Sync + 1nF 1nF 1nF 1nF A 1nF 1nF 1nF 1nF 1uF A 1uF 10uH 10uH 10uH 10uH A 10uH 10uH 10uH 10uH 4.7uF 4.7uF 82nF 2.2nF Vehicle Positive Lead 0.47uF 0.47uF 0.47uF 0.47uF 10uH 150 nF 150nF 150 nF 150nF 150nF 150nF 150nF 150nF 1W 1W 1W 1W 1W 1W 1W 1W 1000uF 1000uF 100nF 1nF 1nF 1nF 1nF 1nF 1nF 1nF 1nF 100nF A S0235-01 4W 4W 4W 4W www.ti.com TAS5414 TAS5424 SLOS514 – FEBRUARY 2007 APPLICATION INFORMATION Figure 27. TAS5414 Application Schematic 35 Figure 28. TAS5424 Typical Application Schematic GND System Microprocessor SGND Ground Plane FAST MUTE PGND Optional 330nF 9 12 11 Submit Documentation Feedback 15 17 21 1uF 22 1uF IN4_M IN4_P PVDD PVDD PVDD 1uF 20 IN3_M OUT4_M PGND PGND OUT3_P OUT3_M PGND CPC_ BOT CP CPC_ TOP OUT2_P OUT2_M PGND PGND OUT1_P OUT1_M PVDD PVDD PVDD OUT4_P IN2_M IN2_P IN1_M IN1_P A_ BYP REXT SGND GND CLIP_OTW D_ BYP STANDBY GND MUTE FAULT SCL SDA I2C_ ADDR OSC_ SYNC Vehicle Negative Lead (GND) Reverse Battery Protection IN3_P 1uF 19 1uF 18 1uF 1uF 16 1uF 100nF14 20kW, 1% 13 100nF 8 7 6 5 4 3 2 1 10 VBATT 8V–22V "0": V0 (to SGND) (OSC Master Default) "1": V1 (OSC Slave 1) "2": V2 (OSC Slave 2) "3": V3 (to D_BYP) (OSC Slave 3) Additional TAS5424 Sync Additional TAS5424 Sync Additional TAS5424 Sync Pull-up Resistors 36 Audio Inputs 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 Vehicle Positive Lead 5.6W A 5.6W 5.6W 5.6W 5.6W 5.6W 5.6W 5.6W A 1nF 1nF 1nF 1nF 1uF 1nF 1nF 1nF 1nF 1uF 10uH 10uH 10uH 10uH A 10uH 10uH 10uH 10uH 4.7uF 4.7uF 82nF 2.2nF 0.47uF 0.47uF 0.47uF 0.47uF 10uH 150nF 150nF 150nF 150nF 150nF 150nF 150nF 150nF 1W 1W 1W 1W 1W 1W 1W 1W 1000uF 1000uF 100nF 1nF 1nF 1nF 1nF 1nF 1nF 1nF 1nF 100nF A S0236-01 4W 4W 4W 4W TAS5414 TAS5424 SLOS514 – FEBRUARY 2007 www.ti.com APPLICATION INFORMATION (continued) TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 APPLICATION INFORMATION (continued) Parallel Operation (PBTL) TAS5414 and TAS5424 can be used to drive four 4Ω loads, two 2Ω loads, or even one 1Ω load by paralleling BTL channels on the load side of the LC output filter. For parallel operation, identical I2C settings are required for any two paralleled channels (especially gain and current-limit settings) in order to have reliable system performance and evenly dissipated power on multiple channels. Having identical gain and current-limit settings can also prevent energy feeding back from one channel to the other. For smooth power up, power down, and mute operation, the same control commands (such as mute, play, Hi-Z, etc.) should be sent to the paralleled channels at the same time. Load diagnostic is also supported for parallel connection. Paralleling on the TAS5414 and TAS5424 side of the LC output filter is not supported, and can result in device failure. DEMODULATION FILTER DESIGN The TAS5414 and TAS5424 amplifier outputs are driven by high-current LDMOS transistors in an H-bridge configuration. These transistors are either off or fully on. The result is a square-wave output signal with a duty cycle that is proportional to the amplitude of the audio signal. It is recommended that a second-order LC filter be used to recover the audio signal. The main purpose of the demodulation filter is to attenuate the high-frequency components of the output signals that are out of the audio band. Design of the demodulation filter significantly affects the audio performance of the power amplifier. Therefore, to meet the device THD+N specification, the selection of the inductors used in the output filter should be carefully considered. The rule is that the inductance should remain stable within the range of peak current seen at maximum output power and deliver approximately 5 µH of inductance at 16 A. If this rule is observed, the TAS5414 and TAS5424 should not have distortion issues due to the output inductors. Another parameter to be considered is the idle-current loss in the inductor. This can be measured or specified as inductor dissipation (D). The target specification for dissipation is less than 0.05. If the dissipation factor is above this value, idle current increases. In general, 10-µH inductors suffice for most applications. The frequency response of the amplifier is slightly altered by the change in output load resistance; however, unless tight control of frequency response is necessary (better than 0.5 dB), it is not necessary to deviate from 10 µH. THERMAL INFORMATION The thermally augmented package provided with the TAS5414 and TAS5424 is designed to interface directly to heat sinks using a thermal interface compound (for example, Artic Silver, Ceramique thermal compound.) The heat sink then absorbs heat from the ICs and couples it to the local air. If louvers or fans are supplied, this process can reach equilibrium and heat can be continually removed from the ICs. Because of the efficiency of the TAS5414 and TAS5424, heat sinks can be smaller than those required for linear amplifiers of equivalent performance. RθJA is a system thermal resistance from junction to ambient air. As such, it is a system parameter with the following components: • RθJC (the thermal resistance from junction to case, or in this case the heat slug) • Thermal grease thermal resistance • Heat sink thermal resistance The thermal grease thermal resistance can be calculated from the exposed heat slug area and the thermal grease manufacturer's area thermal resistance (expressed in °C-in2/W or °C-mm2/W). The area thermal resistance of the example thermal grease with a 0.001-inch (0.0254-mm) thick layer is about 0.007°C-in2/W (4.52°C-mm2/W). The approximate exposed heat slug size is as follows: TAS5424, 44-pin PSOP3 …………………. 0.124 in2 (80 mm2) TAS5414, 36-pin PSOP3 …………………. 0.124 in2 (80 mm2) Dividing the example thermal grease area resistance by the area of the heat slug gives the actual resistance through the thermal grease for both parts: TAS5424, 44-pin PSOP3 ………………… 0.40°C/W TAS5414, 36-pin PSOP3 ………………… 0.40°C/W Submit Documentation Feedback 37 TAS5414 TAS5424 www.ti.com SLOS514 – FEBRUARY 2007 APPLICATION INFORMATION (continued) The thermal resistance of thermal pads is generally considerably higher than a thin thermal grease layer. Thermal tape has an even higher thermal resistance and should not be used at all. Heat sink thermal resistance generally is predicted by the heat sink vendor, modeled using a continuous flow dynamics (CFD) model, or measured. Thus, for a single monaural channel in the IC, the system RθJA = RθJC + thermal grease resistance + heat sink resistance. The following table indicates modeled parameters for one TAS5414 or TAS5424 IC on a heat sink. The junction temperature is set at 115°C in both cases while delivering 20 Wrms per channel into 4-Ω loads with no clipping. It is assumed that the thermal grease is about 0.001 inches (0.0254 mm) thick (this is critical). Device TAS5414, 36-Pin PSOP3 Ambient temperature 25°C Power to load 20 W × 4 Power dissipation 1.90 W × 4 ∆T inside package 7.6°C ∆T through thermal grease 3°C Required heatsink thermal resistance 10.45°C/W Junction temperature 115°C System RθJA 11.85°C/W RθJA × power dissipation 90°C As an indication of the importance of keeping the thermal grease layer thin, if the thermal grease layer increases to 0.002 inches (0.0508 mm) thick, the required heat sink thermal resistance changes to 6°C/W for the PSOP3. 38 Submit Documentation Feedback PACKAGE OPTION ADDENDUM www.ti.com 28-May-2007 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty TAS5414TDKDMQ1 ACTIVE SSOP DKD 36 29 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5414TDKDQ1 ACTIVE SSOP DKD 36 29 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5414TDKDQ1G4 ACTIVE SSOP DKD 36 29 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5414TDKDRMQ1 ACTIVE SSOP DKD 36 500 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5414TDKDRQ1 ACTIVE SSOP DKD 36 500 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5414TDKDRQ1G4 ACTIVE SSOP DKD 36 500 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5424TDKDQ1 ACTIVE SSOP DKD 44 29 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5424TDKDQ1G4 ACTIVE SSOP DKD 44 29 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5424TDKDRQ1 ACTIVE SSOP DKD 44 500 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR TAS5424TDKDRQ1G4 ACTIVE SSOP DKD 44 500 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-245C-168 HR Lead/Ball Finish MSL Peak Temp (3) (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 26-May-2007 TAPE AND REEL INFORMATION Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com Device 26-May-2007 Package Pins Site Reel Diameter (mm) Reel Width (mm) A0 (mm) B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant TAS5414TDKDRMQ1 DKD 36 TAI 330 24 14.7 16.4 4.0 20 24 Q1 TAS5414TDKDRQ1 DKD 36 TAI 330 24 14.7 16.4 4.0 20 24 Q1 TAS5424TDKDRQ1 DKD 44 TAI 330 24 14.7 16.4 4.0 20 24 Q1 TAPE AND REEL BOX INFORMATION Device Package Pins Site Length (mm) Width (mm) Height (mm) TAS5414TDKDRMQ1 DKD 36 TAI 559.0 261.0 122.0 TAS5414TDKDRQ1 DKD 36 TAI 0.0 0.0 0.0 TAS5424TDKDRQ1 DKD 44 TAI 0.0 0.0 0.0 Pack Materials-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 26-May-2007 Pack Materials-Page 3 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security RFID www.ti-rfid.com Telephony www.ti.com/telephony Low Power Wireless www.ti.com/lpw Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2007, Texas Instruments Incorporated