B A 150+/-15 6.35+/-1.5 21.5+/-1.25 6.35 +0 -.12 6.35+/-1.5 25.4+/-.15 150 6.35 tinned 3.6+/-1.0 7.2 4.8 MAX 3/8 24 U.N.F.-2A Lens-End Halogen Lamps Line No. Part No. Volts Amps L1041, PAGE 17 Color Temp. Degrees Kelvin Lumens 1 L1041 5.0 1.350 70 2 L1051-C 6.0 1.900 160 See Light Distribution below, (L1041 figure 1, L1051 figure 2) C Life Hours 2,800 2,900 1,500 1,000 150+/-15 6.35+/-1.5 L1051, PAGE 17 Base Type C-6 C-6 Brass Nickel Plated 24 UNF-2A D 21.5+/-1.25 +0 6.35 -.12 Filament Type 3.6+/-1.0 Drawing 6.35+/-1.5 25.4+/-.15 150 A B 6.35 tinned 7.2 4.8 MAX 0.5 MIN 3/8 24 U.N.F.-2A Figure 1: 1/4” Diameter Lamps L1040, PAGE 17 Mounting, Working Plane & Typical Working Plane Pattern (mounting set screw to contact back 1/3 of lamp only) 2.5 MIN L1050, PAGE 17 Working Plane 0.5-3mm from lamp Working Plane Pattern 2.5mm Figure 2: 1/2” & 3/8” Diameter Lamps Mounting, Working Plane & Typical Working Plane Pattern Working Plane 0.5-3mm from lamp Working Plane Pattern 6.0mm Clear-End Halogen Lamps Line No. 3 4 5 16 Part No. L1031 L1040 L1050-C Volts Amps Lumens 3.5 5.0 6.0 1.200 1.350 1.900 40 70 160 Telephone: 781-935-4442 Fax: 781-938-5867 Color Temp. Degrees Kelvin 2,950 2,800 2.900 Life Hours 150 1,500 1,000 Filament Type C-6 C-6 C-6 Filament Dimensions Lgth. x Dia. Base Type Drawing 1.2 X 0.6Brass Nickel PlatedC 1.6 X 0.7Brass Nickel PlatedC 2.5 X 0.7 24 UNF-2A D [email protected] www.gilway.com Engineering Catalog 169