HY5DU283222AF 128M(4Mx32) GDDR SDRAM HY5DU283222AF This document is a general product description and is subject to change without notice. Hynix Electronics does not assume any responsibility for use of circuits described. No patent licenses are implied. Rev. 0.7 / Jun. 2004 1 HY5DU283222AF Revision History Revision No. History Draft Date 0.1 Defined target spec. Nov. 2002 0.11 500MHz speed bin added Dec. 2002 0.2 Defined IDD specification Feb. 2003 0.3 1) Added 222MHz with CL3 and tCK_max=10ns at HY5DU283222AF-36 2) Changed VDD_min value of HY5DU283222AF-36 from 2.375V to 2.2V 3) Changed AC parameters value of HY5DU283222AF-28/33 - tRCDRD/tRP : from 6 tCK to 5 tCK - tDAL : from 9 tCK to 8 tCK - tRFC : from 19 tCK to 17 tCK 4) Changed IDD2N target specification 5) Changed tCK_max value of HY5DU283222AF-33/36 from 6ns to 10ns Mar. 2003 0.4 Changed CAS Latency of HY5DU283222AF-28 from CL5 to CL4 June 2003 0.5 Changed tRAS_max Value from 120K to 100K in All Frequency Aug. 2003 0.6 Insert Overshoot/ Under Specification Insert tDSS/ tDSH parameter Sep. 2003 0.7 Added 250MHz/ 200MHz speed bin Jun. 2004 Rev. 0.7 / Jun. 2004 Remark 2 HY5DU283222AF DESCRIPTION The Hynix HY5DU283222 is a 134,217,728-bit CMOS Double Data Rate(DDR) Synchronous DRAM, ideally suited for the point-to-point applications which requires high bandwidth. The Hynix 4Mx32 DDR SDRAMs offer fully synchronous operations referenced to both rising and falling edges of the clock. While all addresses and control inputs are latched on the rising edges of the CK (falling edges of the /CK), Data, Data strobes and Write data masks inputs are sampled on both rising and falling edges of it. The data paths are internally pipelined and 2-bit prefetched to achieve very high bandwidth. All input and output voltage levels are compatible with SSTL_2. FEATURES • 2.5V +/- 5% VDD and VDDQ power supply supports 300 / 275 / 250 / 200 MHz • Data(DQ) and Write masks(DM) latched on the both rising and falling edges of the data strobe • 2.8V +/- 5% VDD and VDDQ power supply supports 500/450/400/350MHz • • All inputs and outputs are compatible with SSTL_2 interface All addresses and control inputs except Data, Data strobes and Data masks latched on the rising edges of the clock • Write mask byte controls by DM (DM0 ~ DM3) • 12mm x 12mm, 144ball FBGA with 0.8mm pin pitch • Programmable /CAS Latency 5, 4 and 3 supported • Fully differential clock inputs (CK, /CK) operation • • Double data rate interface Programmable Burst Length 2 / 4 / 8 with both sequential and interleave mode • Source synchronous - data transaction aligned to bidirectional data strobe (DQS0 ~ DQS3) • Internal 4 bank operations with single pulsed /RAS • tRAS Lock-Out function supported • Auto refresh and self refresh supported • 4096 refresh cycles 32ms • Half strength and Matched Impedance driver option controlled by EMRS • Data outputs on DQS edges when read (edged DQ) Data inputs on DQS centers when write (centered DQ) ORDERING INFORMATION Part No. Power Supply HY5DU283222AF-2 Clock Frequency Max Data Rate 500MHz 1000Mbps/pin HY5DU283222AF-22 VDD 2.8V 450MHz 900Mbps/pin HY5DU283222AF-25 VDDQ 2.8V 400MHz 800Mbps/pin HY5DU283222AF-28 350MHz 700Mbps/pin HY5DU283222AF-33 300MHz 600Mbps/pin HY5DU283222AF-36 VDD 2.5V 275MHz 550Mbps/pin HY5DU283222AF-4 VDDQ 2.5V 250MHz 500Mbps/pin 200MHz 400Mbps/pin HY5DU283222AF-5 Rev. 0.7 / Jun. 2004 interface SSTL_2 Package 12mm x 12mm 144Ball FBGA 3 HY5DU283222AF PIN CONFIGURATION (Top View) 1 2 3 4 5 6 7 8 9 10 11 12 13 B DQS0 DM0 VSSQ DQ3 DQ2 DQ0 DQ31 DQ29 DQ28 VSSQ DM3 DQS3 C DQ4 VDDQ NC VDDQ DQ1 VDDQ VDDQ DQ30 VDDQ NC VDDQ DQ27 D DQ6 DQ5 VSSQ VSSQ VSSQ VDD VDD VSSQ VSSQ VSSQ DQ26 DQ25 E DQ7 VDDQ VDD VSS VSSQ VSS VSS VSSQ VSS VDD VDDQ DQ24 F DQ17 DQ16 VDDQ VSSQ VSS Termal VSS Termal VSS Termal VSS Termal VSSQ VDDQ DQ15 DQ14 G DQ19 DQ18 VDDQ VSSQ VSS Termal VSS Termal VSS Termal VSS Termal VSSQ VDDQ DQ13 DQ12 H DQS2 DM2 NC VSSQ VSS Termal VSS Termal VSS Termal VSS Termal VSSQ NC DM1 DQS1 J DQ21 DQ20 VDDQ VSSQ VSS Termal VSS Termal VSS Termal VSS Termal VSSQ VDDQ DQ11 DQ10 K DQ22 DQ23 VDDQ VSSQ VSS VSS VSS VSS VSSQ VDDQ DQ9 DQ8 L /CAS /W/E VDD VSS A10 VDD VDD NC2 VSS VDD NC NC M /RAS NC NC BA1 A2 A11 A9 A5 NC3 CLK /CLK NC N /CS NC BA0 A0 A1 A3 A4 A6 A7 A8/AP CKE VREF 14 A P Note : 1. Outer ball, A1~A14, P1~P14, A1~P1, A14~P14 are depopulated. 2. Ball L9(NC2) is reserved for A12. 3. Ball M10(NC3) is reserved for BA2. ROW and COLUMN ADDRESS TABLE Rev. 0.7 / Jun. 2004 Items 4Mx32 Organization 1M x 32 x 4banks Row Address A0 ~ A11 Column Address A0 ~ A7 Bank Address BA0, BA1 Auto Precharge Flag A8 Refresh 4K 4 HY5DU283222AF PIN DESCRIPTION PIN TYPE CK, /CK Input Clock: CK and /CK are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CK and negative edge of /CK. Output (read) data is referenced to the crossings of CK and /CK (both directions of crossing). CKE Input Clock Enable: CKE HIGH activates, and CKE LOW deactivates internal clock signals, and device input buffers and output drivers. Taking CKE LOW provides PRECHARGE POWER DOWN and SELF REFRESH operation (all banks idle), or ACTIVE POWER DOWN (row ACTIVE in any bank). CKE is synchronous for POWER DOWN entry and exit, and for SELF REFRESH entry. CKE is asynchronous for SELF REFRESH exit, and for output disable. CKE must be maintained high throughout READ and WRITE accesses. Input buffers, excluding CK, /CK and CKE are disabled during POWER DOWN. Input buffers, excluding CKE are disabled during SELF REFRESH. CKE is an SSTL_2 input, but will detect an LVCMOS LOW level after Vdd is applied. /CS Input Chip Select : Enables or disables all inputs except CK, /CK, CKE, DQS and DM. All commands are masked when CS is registered high. CS provides for external bank selection on systems with multiple banks. CS is considered part of the command code. BA0, BA1 Input Bank Address Inputs: BA0 and BA1 define to which bank an ACTIVE, Read, Write or PRECHARGE command is being applied. A0 ~ A11 Input Address Inputs: Provide the row address for ACTIVE commands, and the column address and AUTO PRECHARGE bit for READ/WRITE commands, to select one location out of the memory array in the respective bank. A8 is sampled during a precharge command to determine whether the PRECHARGE applies to one bank (A8 LOW) or all banks (A8 HIGH). If only one bank is to be precharged, the bank is selected by BA0, BA1. The address inputs also provide the op code during a MODE REGISTER SET command. BA0 and BA1 define which mode register is loaded during the MODE REGISTER SET command (MRS or EMRS). /RAS, /CAS, /WE Input Command Inputs: /RAS, /CAS and /WE (along with /CS) define the command being entered. DM0 ~ DM3 Input Input Data Mask: DM(0~3) is an input mask signal for write data. Input data is masked when DM is sampled HIGH along with that input data during a WRITE access. DM is sampled on both edges of DQS. Although DM pins are input only, the DM loading matches the DQ and DQS loading. DM0 corresponds to the data on DQ0-Q7; DM1 corresponds to the data on DQ8-Q15; DM2 corresponds to the data on DQ16-Q23; DM3 corresponds to the data on DQ24-Q31. DQS0 ~ DQS3 I/O Data Strobe: Output with read data, input with write data. Edge aligned with read data, centered in write data. Used to capture write data. DQS0 corresponds to the data on DQ0-Q7; DQS1 corresponds to the data on DQ8-Q15; DQS2 corresponds to the data on DQ16-Q23; DQS3 corresponds to the data on DQ24-Q31 DQ0 ~ DQ31 I/O Data input / output pin : Data Bus VDD/VSS Supply Power supply for internal circuits and input buffers. VDDQ/VSSQ Supply Power supply for output buffers for noise immunity. VREF Supply Reference voltage for inputs for SSTL interface. NC NC Rev. 0.7 / Jun. 2004 DESCRIPTION No connection. 5 HY5DU283222AF FUNCTIONAL BLOCK DIAGRAM 4Banks x 1Mbit x 32 I/O Double Data Rate Synchronous DRAM Input Buffer 32 Write Data Register 2-bit Prefetch Unit 64 1Mx32/Bank0 1Mx32 /Bank2 64 1Mx32 /Bank3 Mode Register 32 Output Buffer 1Mx32 /Bank1 Command Decoder 2-bit Prefetch Unit Bank Control Sense AMP CLK /CLK CKE /CS /RAS /CAS /WE DM(0~3) DS DQ[0:31] Row Decoder Column Decoder A0-11 BA0,BA1 Address Buffer DQS(0~3) Column Address Counter Data Strobe Transmitter CLK_DLL DS CLK, /CLK Data Strobe Receiver DLL Block Mode Register Rev. 0.7 / Jun. 2004 6 HY5DU283222AF SIMPLIFIED COMMAND TRUTH TABLE A8/ AP Command CKEn-1 CKEn CS RAS CAS WE Extended Mode Register Set H X L L L L OP code 1,2 Mode Register Set H X L L L L OP code 1,2 H X H X X X L H H H X 1 H X L L H H H X L H L H CA H X L H L L CA H X L L H L X Read Burst Stop H X L H H L X 1 Auto Refresh H H L L L H X 1 Entry H L L L L H Exit L H H X X X L H H H Entry H L H X X X L H H H H X X X L H H H 1 H X X X 1 L V V V Device Deselect No Operation Bank Active Read Read with Autoprecharge Write Write with Autoprecharge Precharge All Banks Precharge selected Bank Self Refresh Precharge Power Down Mode Active Power Down Mode Exit L H Entry H L Exit L H X ADDR RA BA V L H L H V V Note 1 1 1,3 1 1,4 H X 1,5 L V 1 1 X 1 1 X X 1 1 1 1 ( H=Logic High Level, L=Logic Low Level, X=Don’t Care, V=Valid Data Input, OP Code=Operand Code, NOP=No Operation ) Note : 1. DM(0~3) states are Don’t Care. Refer to below Write Mask Truth Table. 2. OP Code(Operand Code) consists of A0~A11 and BA0~BA1 used for Mode Register setting during Extended MRS or MRS. Before entering Mode Register Set mode, all banks must be in a precharge state and MRS command can be issued after tRP period from Prechagre command. 3. If a Read with Autoprecharge command is detected by memory component in CK(n), then there will be no command presented to activated bank until CK(n+BL/2+tRP). 4. If a Write with Autoprecharge command is detected by memory component in CK(n), then there will be no command presented to activated bank until CK(n+BL/2+1+tDPL+tRP). Last Data-In to Prechage delay(tDPL) which is also called Write Recovery Time (tWR) is needed to guarantee that the last data has been completely written. 5. If A8/AP is High when Precharge command being issued, BA0/BA1 are ignored and all banks are selected to be precharged. Rev. 0.7 / Jun. 2004 7 HY5DU283222AF WRITE MASK TRUTH TABLE CKEn-1 CKEn /CS, /RAS, /CAS, /WE DM(0~3) Data Write H X X L X 1,2 Data-In Mask H X X H X 1,2 Function ADDR A8/ AP BA Note Note : 1. Write Mask command masks burst write data with reference to DQS(0~3) and it is not related with read data. 2. DM0 corresponds to the data on DQ0-Q7; DM1 corresponds to the data on DQ8-Q15; DM2 corresponds to the data on DQ16-Q23; DM3 corresponds to the data on DQ24-Q31. Rev. 0.7 / Jun. 2004 8 HY5DU283222AF OPERATION COMMAND TRUTH TABLE - I Current State IDLE ROW ACTIVE READ WRITE /CS /RAS /CAS /WE Address Command Action H X X X X DSEL NOP or power down3 L H H H X NOP NOP or power down3 L H H L X BST ILLEGAL4 L H L H BA, CA, AP READ/READAP ILLEGAL4 L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL4 L L H H BA, RA ACT Row Activation L L H L BA, AP PRE/PALL NOP L L L H X AREF/SREF Auto Refresh or Self Refresh5 L L L L OPCODE MRS Mode Register Set H X X X X DSEL NOP L H H H X NOP NOP L H H L X BST ILLEGAL4 L H L H BA, CA, AP READ/READAP Begin read : optional AP6 L H L L BA, CA, AP WRITE/WRITEAP Begin write : optional AP6 L L H H BA, RA ACT ILLEGAL4 L L H L BA, AP PRE/PALL Precharge7 L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL Continue burst to end L H H H X NOP Continue burst to end L H H L X BST Terminate burst L H L H BA, CA, AP READ/READAP Term burst, new read:optional AP8 L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL L L H H BA, RA ACT ILLEGAL4 L L H L BA, AP PRE/PALL Term burst, precharge L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL Continue burst to end L H H H X NOP Continue burst to end L H H L X BST ILLEGAL4 L H L H BA, CA, AP READ/READAP Term burst, new read:optional AP8 L H L L BA, CA, AP WRITE/WRITEAP Term burst, new write:optional AP Rev. 0.7 / Jun. 2004 9 HY5DU283222AF OPERATION COMMAND TRUTH TABLE - II Current State WRITE READ WITH AUTOPRECHARGE WRITE AUTOPRECHARGE PRECHARGE /CS /RAS /CAS /WE Address Command Action L L H H BA, RA ACT ILLEGAL4 L L H L BA, AP PRE/PALL Term burst, precharge L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL Continue burst to end L H H H X NOP Continue burst to end L H H L X BST ILLEGAL L H L H BA, CA, AP READ/READAP ILLEGAL10 L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL10 L L H H BA, RA ACT ILLEGAL4,10 L L H L BA, AP PRE/PALL ILLEGAL4,10 L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL Continue burst to end L H H H X NOP Continue burst to end L H H L X BST ILLEGAL L H L H BA, CA, AP READ/READAP ILLEGAL10 L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL10 L L H H BA, RA ACT ILLEGAL4,10 L L H L BA, AP PRE/PALL ILLEGAL4,10 L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL NOP-Enter IDLE after tRP L H H H X NOP NOP-Enter IDLE after tRP L H H L X BST ILLEGAL4 L H L H BA, CA, AP READ/READAP ILLEGAL4,10 L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL4,10 L L H H BA, RA ACT ILLEGAL4,10 L L H L BA, AP PRE/PALL NOP-Enter IDLE after tRP L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 Rev. 0.7 / Jun. 2004 10 HY5DU283222AF OPERATION COMMAND TRUTH TABLE - III Current State ROW ACTIVATING WRITE RECOVERING WRITE RECOVERING WITH AUTOPRECHARGE REFRESHING /CS /RAS /CAS /WE Address Command Action H X X X X DSEL NOP - Enter ROW ACT after tRCD L H H H X NOP NOP - Enter ROW ACT after tRCD L H H L X BST ILLEGAL4 L H L H BA, CA, AP READ/READAP ILLEGAL4,10 L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL4,10 L L H H BA, RA ACT ILLEGAL4,9,10 L L H L BA, AP PRE/PALL ILLEGAL4,10 L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL NOP - Enter ROW ACT after tWR L H H H X NOP NOP - Enter ROW ACT after tWR L H H L X BST ILLEGAL4 L H L H BA, CA, AP READ/READAP ILLEGAL L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL L L H H BA, RA ACT ILLEGAL4,10 L L H L BA, AP PRE/PALL ILLEGAL4,11 L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL NOP - Enter precharge after tDPL L H H H X NOP NOP - Enter precharge after tDPL L H H L X BST ILLEGAL4 L H L H BA, CA, AP READ/READAP ILLEGAL4,8,10 L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL4,10 L L H H BA, RA ACT ILLEGAL4,10 L L H L BA, AP PRE/PALL ILLEGAL4,11 L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL NOP - Enter IDLE after tRC L H H H X NOP NOP - Enter IDLE after tRC L H H L X BST ILLEGAL11 L H L H BA, CA, AP READ/READAP ILLEGAL11 Rev. 0.7 / Jun. 2004 11 HY5DU283222AF OPERATION COMMAND TRUTH TABLE - IV Current State WRITE MODE REGISTER ACCESSING /CS /RAS /CAS /WE Address Command Action L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL11 L L H H BA, RA ACT ILLEGAL11 L L H L BA, AP PRE/PALL ILLEGAL11 L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 H X X X X DSEL NOP - Enter IDLE after tMRD L H H H X NOP NOP - Enter IDLE after tMRD L H H L X BST ILLEGAL11 L H L H BA, CA, AP READ/READAP ILLEGAL11 L H L L BA, CA, AP WRITE/WRITEAP ILLEGAL11 L L H H BA, RA ACT ILLEGAL11 L L H L BA, AP PRE/PALL ILLEGAL11 L L L H X AREF/SREF ILLEGAL11 L L L L OPCODE MRS ILLEGAL11 Note : 1. H - Logic High Level, L - Logic Low Level, X - Don’t Care, V - Valid Data Input, BA - Bank Address, AP - AutoPrecharge Address, CA - Column Address, RA - Row Address, NOP - NO Operation. 2. All entries assume that CKE was active(high level) during the preceding clock cycle. 3. If both banks are idle and CKE is inactive(low level), then in power down mode. 4. Illegal to bank in specified state. Function may be legal in the bank indicated by Bank Address(BA) depending on the state of that bank. 5. If both banks are idle and CKE is inactive(low level), then self refresh mode. 6. Illegal if tRCD is not met. 7. Illegal if tRAS is not met. 8. Must satisfy bus contention, bus turn around, and/or write recovery requirements. 9. Illegal if tRRD is not met. 10. Illegal for single bank, but legal for other banks in multi-bank devices. 11. Illegal for all banks. Rev. 0.7 / Jun. 2004 12 HY5DU283222AF CKE FUNCTION TRUTH TABLE Current State SELF REFRESH1 POWER DOWN2 ALL BANKS IDLE4 ANY STATE OTHER THAN ABOVE CKEn1 CKEn /CS /RAS /CAS /WE /ADD Action H X X X X X X INVALID L H H X X X X Exit self refresh, enter idle after tSREX L H L H H H X Exit self refresh, enter idle after tSREX L H L H H L X ILLEGAL L H L H L X X ILLEGAL L H L L X X X ILLEGAL L L X X X X X NOP, continue self refresh H X X X X X X INVALID L H H X X X X Exit power down, enter idle L H L H H H X Exit power down, enter idle L H L H H L X ILLEGAL L H L H L X X ILLEGAL L H L L X X X ILLEGAL L L X X X X X NOP, continue power down mode H H X X X X X See operation command truth table H L L L L H X Enter self refresh H L H X X X X Exit power down H L L H H H X Exit power down H L L H H L X ILLEGAL H L L H L X X ILLEGAL H L L L H X X ILLEGAL H L L L L L X ILLEGAL L L X X X X X NOP H H X X X X X See operation command truth table H L X X X X X ILLEGAL5 L H X X X X X INVALID L L X X X X X INVALID Note : When CKE=L, all DQ and DQS(0~3) must be in Hi-Z state. 1. CKE and /CS must be kept high for a minimum of 200 stable input clocks before issuing any command. 2. All command can be stored after 2 clocks from low to high transition of CKE. 3. Illegal if CK is suspended or stopped during the power down mode. 4. Self refresh can be entered only from the all banks idle state. 5. Disabling CK may cause malfunction of any bank which is in active state. Rev. 0.7 / Jun. 2004 13 HY5DU283222AF SIMPLIFIED STATE DIAGRAM MRS MODE REGISTER SET SREF SELF REFRESH IDLE SREX PDEN PDEX AREF ACT POWER DOWN POWER DOWN AUTO REFRESH PDEN BST PDEX BANK ACTIVE READ WRITE READ WRITE WRITEAP WRITE WITH AUTOPRECHARGE PRE(PALL) READAP READ READAP WITH AUTOPRECHARGE WRITEAP READ WRITE PRE(PALL) PRE(PALL) PRECHARGE POWER-UP Command Input Automatic Sequence POWER APPLIED Rev. 0.7 / Jun. 2004 14 HY5DU283222AF POWER-UP SEQUENCE AND DEVICE INITIALIZATION DDR SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation. Except for CKE, inputs are not recognized as valid until after VREF is applied. CKE is an SSTL_2 input, but will detect an LVCMOS LOW level after VDD is applied. Maintaining an LVCMOS LOW level on CKE during power-up is required to guarantee that the DQ and DQS outputs will be in the High-Z state, where they will remain until driven in normal operation (by a read access). After all power supply and reference voltages are stable, and the clock is stable, the DDR SDRAM requires a 200us delay prior to applying an executable command. Once the 200us delay has been satisfied, a DESELECT or NOP command should be applied, and CKE should be brought HIGH. Following the NOP command, a PRECHARGE ALL command should be applied. Next a EXTENDED MODE REGISTER SET command should be issued for the Extended Mode Register, to enable the DLL, then a MODE REGISTER SET command should be issued for the Mode Register, to reset the DLL, and to program the operating parameters. After the DLL reset, tXSRD(DLL locking time) should be satisfied for read command. After the Mode Register set command, a PRECHARGE ALL command should be applied, placing the device in the all banks idle state. Once in the idle state, two AUTO REFRESH cycles must be performed. Additionally, a MODE REGISTER SET command for the Mode Register, with the reset DLL bit deactivated low (i.e. to program operating parameters without resetting the DLL) must be performed. Following these cycles, the DDR SDRAM is ready for normal operation. 1. Apply power - VDD, VDDQ, VTT, VREF in the following power up sequencing and attempt to maintain CKE at LVCMOS low state. (All the other input pins may be undefined. No power sequencing is specified during power up or power down given the following cirteria : • VDD and VDDQ are driven from a single power converter output. • VTT is limited to 1.44V (reflecting VDDQ(max)/2 + 50mV VREF variation + 40mV VTT variation). • VREF tracks VDDQ/2. • A minimum resistance of 42 ohms (22 ohm series resistor + 22 ohm parallel resistor - 5% tolerance) limits the input current from the VTT supply into any pin. If the above criteria cannot be met by the system design, then the following sequencing and voltage relationship must be adhered to during power up : Voltage description Sequencing Voltage relationship to avoid latch-up VDDQ After or with VDD < VDD + 0.3V VTT After or with VDDQ < VDDQ + 0.3V VREF After or with VDDQ < VDDQ + 0.3V 2. Start clock and maintain stable clock for a minimum of 200usec. 3. After stable power and clock, apply NOP condition and take CKE high. 4. Issue Extended Mode Register Set (EMRS) to enable DLL. 5. Issue Mode Register Set (MRS) to reset DLL and set device to idle state with bit A8=high. (An additional 200 cycles(tXSRD) of clock are required for locking DLL) 6. Issue Precharge commands for all banks of the device. Rev. 0.7 / Jun. 2004 15 HY5DU283222AF 7. Issue 2 or more Auto Refresh commands. 8. Issue a Mode Register Set command to initialize the mode register with bit A8 = Low. Power-Up Sequence VDD VDDQ tVTD VTT VREF /CLK CLK tIS tIH CKE LVCMOS Low Level CMD NOP PRE EMRS MRS ADDR CODE A10 BA0, BA1 NOP PRE AREF MRS ACT RD CODE CODE CODE CODE CODE CODE CODE CODE CODE CODE CODE CODE CODE CODE Non-Read Command READ DM DQS DQ'S T=200usec tRP tMRD tMRD tRP tRFC tMRD tXSRD* Power UP VDD and CK stable Precharge All EMRS Set MRS Set Reset DLL (with A8=H) Precharge All 2 or more Auto Refresh MRS Set (with A8=L) * 200 cycle(tXSRD) of CK are required (for DLL locking) before Read Command Rev. 0.7 / Jun. 2004 16 HY5DU283222AF MODE REGISTER SET (MRS) The mode register is used to store the various operating modes such as /CAS latency, addressing mode, burst length, burst type, test mode, DLL reset. The mode register is program via MRS command. This command is issued by the low signals of /RAS, /CAS, /CS, /WE and BA0. This command can be issued only when all banks are in idle state and CKE must be high at least one cycle before the Mode Register Set Command can be issued. Two cycles are required to write the data in mode register. During the the MRS cycle, any command cannot be issued. Once mode register field is determined, the information will be held until resetted by another MRS command. BA1 BA0 0 0 A11 A10 RFU A9 A8 A7 DR TM A6 A5 A4 CAS Latency BA0 MRS Type A7 Test Mode 0 MRS 0 Normal 1 EMRS 1 Vendor test mode A3 A2 BT A1 A0 Burst Length Burst Length Rev. 0.7 / Jun. 2004 A2 A1 A8 DLL Reset 0 No 0 0 1 Yes 0 A0 Sequential Interleave 0 Reserved Reserved 0 1 2 2 0 1 0 4 4 0 1 1 8 8 1 0 0 Reserved Reserved 1 0 1 Reserved Reserved 1 1 0 Reserved Reserved 1 1 1 Reserved Reserved A6 A5 A4 CAS Latency 0 0 0 Reserved 0 0 1 Reserved 0 1 0 Reserved 0 1 1 3 1 0 0 4 1 0 1 5 A3 Burst Type 1 1 0 Reserved 0 Sequential 1 1 1 Reserved 1 Interleave 17 HY5DU283222AF BURST DEFINITION Burst Length Starting Address (A2,A1,A0) Sequential Interleave XX0 0, 1 0, 1 XX1 1, 0 1, 0 X00 0, 1, 2, 3 0, 1, 2, 3 X01 1, 2, 3, 0 1, 0, 3, 2 X10 2, 3, 0, 1 2, 3, 0, 1 X11 3, 0, 1, 2 3, 2, 1, 0 000 0, 1, 2, 3, 4, 5, 6, 7 0, 1, 2, 3, 4, 5, 6, 7 001 1, 2, 3, 4, 5, 6, 7, 0 1, 0, 3, 2, 5, 4, 7, 6 010 2, 3, 4, 5, 6, 7, 0, 1 2, 3, 0, 1, 6, 7, 4, 5 011 3, 4, 5, 6, 7, 0, 1, 2 3, 2, 1, 0, 7, 6, 5, 4 100 4, 5, 6, 7, 0, 1, 2, 3 4, 5, 6, 7, 0, 1, 2, 3 101 5, 6, 7, 0, 1, 2, 3, 4 5, 4, 7, 6, 1, 0, 3, 2 110 6, 7, 0, 1, 2, 3, 4, 5 6, 7, 4, 5, 2, 3, 0, 1 111 7, 0, 1, 2, 3, 4, 5, 6 7, 6, 5, 4, 3, 2, 1, 0 2 4 8 BURST LENGTH & TYPE Read and write accesses to the DDR SDRAM are burst oriented, with the burst length being programmable. The burst length determines the maximum number of column locations that can be accessed for a given Read or Write command. Burst lengths of 2, 4 or 8 locations are available for both the sequential and the interleaved burst types. Reserved states should not be used, as unknown operation or incompatibility with future versions may result. When a Read or Write command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within this block, meaning that the burst wraps within the block if a boundary is reached. The block is uniquely selected by A1-Ai when the burst length is set to two, by A2-Ai when the burst length is set to four and by A3-Ai when the burst length is set to eight (where Ai is the most significant column address bit for a given configuration). The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. The programmed burst length applies to both Read and Write bursts. Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the burst type and is selected via bit A3. The ordering of accesses within a burst is determined by the burst length, the burst type and the starting column address, as shown in Burst Definitionon Table Rev. 0.7 / Jun. 2004 18 HY5DU283222AF CAS LATENCY The Read latency or CAS latency is the delay in clock cycles between the registration of a Read command and the availability of the first burst of output data. The latency can be programmed 3 or 4 or 5 clocks. If a Read command is registered at clock edge n, and the latency is m clocks, the data is available nominally coincident with clock edge n + m. Reserved states should not be used as unknown operation or incompatibility with future versions may result. DLL RESET The DLL must be enabled for normal operation. DLL enable is required during power up initialization, and upon returning to normal operation after having disabled the DLL for the purpose of debug or evaluation. The DLL is automatically disabled when entering self refresh operation and is automatically re-enabled upon exit of self refresh operation. Any time the DLL is enabled, 200 clock cycles must occur to allow time for the internal clock to lock to the externally applied clock before an any command can be issued. OUTPUT DRIVER IMPEDANCE CONTROL This device supports both Half strength driver and Matched impedance driver, intended for lighter load and/or point-topoint environments. Half strength driver is to define about 50% of Full drive strength which is specified to be SSTL_2, Class II, and Matched impedance driver, about 30% of Full drive strength. Rev. 0.7 / Jun. 2004 19 HY5DU283222AF EXTENDED MODE REGISTER SET (EMRS) The Extended Mode Register controls functions beyond those controlled by the Mode Register; these additional functions include DLL enable/disable, output driver strength selection(optional). These functions are controlled via the bits shown below. The Extended Mode Register is programmed via the Mode Register Set command ( BA0=1 and BA1=0) and will retain the stored information until it is programmed again or the device loses power. The Extended Mode Register must be loaded when all banks are idle and no bursts are in progress, and the controller must wait the specified time before initiating any subsequent operation. Violating either of these requirements will result in unspecified operation. BA1 BA0 0 1 A11 A10 A9 RFU* BA0 MRS Type 0 MRS 1 EMRS A8 A7 A6 DS A5 A4 A3 RFU* A2 A1 A0 DS DS DLL A0 DLL enable 0 Enable 1 Diable A2 A6 A1 Output Driver Impedance Control 0 0 0 RFU* 0 0 1 Half (60%) 0 1 0 RFU* 0 1 1 Weak (40%) 1 0 0 RFU* 1 0 1 Semi Half (50%) 1 1 0 RFU* 1 1 1 Semi Weak (30%) * All bits in RFU address fields must be programmed to Zero, all other states are reserved for future usage. Rev. 0.7 / Jun. 2004 20 HY5DU283222AF ABSOLUTE MAXIMUM RATINGS Parameter Ambient Temperature Storage Temperature Voltage on Any Pin relative to VSS Voltage on VDD relative to VSS Symbol Rating TA 0 ~ 70 Unit o C TSTG -55 ~ 125 oC VIN, VOUT -0.5 ~ 3.6 V VDD -0.5 ~ 3.6 V VDDQ -0.5 ~ 3.6 V Output Short Circuit Current IOS 50 mA Power Dissipation PD 2 W TSOLDER 260 ⋅ 10 Voltage on VDDQ relative to VSS Soldering Temperature ⋅ Time o C ⋅ sec Note : Operation at above absolute maximum rating can adversely affect device reliability DC OPERATING CONDITIONS Parameter Symbol Power Supply Voltage VDD Power Supply Voltage VDDQ (TA=0 to 70oC, Voltage referenced to VSS = 0V) Min Typ Max Unit Note 1, 4 2.2 2.5 2.625 V 2.65 2.8 2.95 V 1, 5 2.2 2.5 2.625 V 1, 4 1, 5 2.65 2.8 2.95 V Input High Voltage VIH VREF + 0.15 - VDDQ + 0.3 V Input Low Voltage VIL -0.3 - VREF - 0.15 V Termination Voltage VTT VREF - 0.04 VREF VREF + 0.04 V Reference Voltage VREF 0.49*VDDQ 0.5*VDDQ 0.51*VDDQ V 2 3 Note : 1. VDDQ must not exceed the level of VDD. 2. VIL (min) is acceptable -1.5V AC pulse width with ≤ 5ns of duration. 3. VREF is expected to be equal to 0.5*VDDQ of the transmitting device, and to track variations in the DC level of the same. Peak to peak noise on VREF may not exceed ± 2% of the DC value. 4. Supports 300/275/250/200MHz 5. Supports 500/450/400/350MHz DC CHARACTERISTICS I Parameter (TA=0 to 70oC, Voltage referenced to VSS = 0V) Symbol Min Max Unit Note Input Leakage Current ILI -2 2 uA 1 Output Leakage Current ILO -5 5 uA 2 Output High Voltage VOH VTT + 0.76 - V IOH = -15.2mA Output Low Voltage VOL - VTT - 0.76 V IOL = +15.2mA Note : 1. VIN = 0 to 3.6V, All other pins are not tested under VIN =0V. 2. DOUT is disabled, VOUT=0 to 2.7V Rev. 0.7 / Jun. 2004 21 HY5DU283222AF DC CHARACTERISTICS II (TA=0 to 70oC, Voltage referenced to VSS = 0V) Speed Parameter Symbol Test Condition Unit Note 2 22 25 28 33 36 4 5 230 210 190 180 170 160 150 140 mA 1 1 Operating Current IDD0 One bank; Active - Precharge; tRC=tRC(min); tCK=tCK(min); DQ,DM and DQS inputs changing twice per clock cycle; address and control inputs changing once per clock cycle Operating Current IDD1 Burst length=4, One bank active tRC ≥ tRC(min), IOL=0mA 250 230 210 200 190 180 170 160 mA Precharge Standby Current in Power Down Mode IDD2P CKE ≤ VIL(max), tCK=min 45 40 35 30 25 25 25 25 mA Precharge Standby Current in Non Power Down Mode IDD2N CKE ≥ VIH(min), /CS ≥ VIH(min), tCK = min, Input signals are changed one time during 2clks 140 130 120 110 100 90 90 80 mA Active Standby Current in Power Down Mode IDD3P CKE ≤ VIL(max), tCK=min 50 45 40 35 30 30 30 30 mA Active Standby Current in Non Power Down Mode IDD3N CKE ≥ VIH(min), /CS ≥ VIH(min), tCK=min, Input signals are changed one time during 2clks 190 170 150 130 115 110 110 100 mA Burst Mode Operating Current IDD4 tCK ≥ tCK(min), IOL=0mA All banks active 750 700 650 590 500 450 450 370 mA 1 Auto Refresh Current IDD5 tRC ≥ tRFC(min), All banks active 400 400 350 350 300 300 270 270 mA 1,2 Self Refresh Current IDD6 CKE ≤ 0.2V 3 3 3 3 3 3 3 3 mA Operating Current Four Bank Operation IDD7 Four bank interleaving with BL=4, Refer to the following page for 1100 1000 detailed test condition 900 800 700 600 600 600 mA Note : 1. IDD1, IDD4 and IDD5 depend on output loading and cycle rates. Specified values are measured with the output open. 2. Min. of tRFC (Auto Refresh Row Cycle Time) is shown at AC CHARACTERISTICS. Rev. 0.7 / Jun. 2004 22 HY5DU283222AF AC OPERATING CONDITIONS (TA=0 to 70oC, Voltage referenced to VSS = 0V) Parameter Symbol Min Max Input High (Logic 1) Voltage, DQ, DQS and DM signals VIH(AC) VREF + 0.35 Input Low (Logic 0) Voltage, DQ, DQS and DM signals VIL(AC) Input Differential Voltage, CK and /CK inputs VID(AC) Input Crossing Point Voltage, CK and /CK inputs VIX(AC) Unit Note V VREF - 0.35 V 0.7 VDDQ + 0.6 V 1 0.5*VDDQ-0.2 0.5*VDDQ+0.2 V 2 Note : 1. VID is the magnitude of the difference between the input level on CK and the input on /CK. 2. The value of VIX is expected to equal 0.5*VDDQ of the transmitting device and must track variations in the DC level of the same. AC OPERATING TEST CONDITIONS (TA=0 to 70oC, Voltage referenced to VSS = 0V) Parameter Value Unit Reference Voltage VDDQ x 0.5 V Termination Voltage VDDQ x 0.5 V AC Input High Level Voltage (VIH, min) VREF + 0.35 V AC Input Low Level Voltage (VIL, max) VREF - 0.35 V Input Timing Measurement Reference Level Voltage VREF V Output Timing Measurement Reference Level Voltage VTT V Input Signal maximum peak swing 1.5 V Input minimum Signal Slew Rate 1 V/ns Termination Resistor (RT) 50 Ω Series Resistor (RS) 25 Ω Output Load Capacitance for Access Time Measurement (CL) 30 pF Rev. 0.7 / Jun. 2004 23 HY5DU283222AF AC Overshoot/Undershoot specifications for Address and Command pins Parameter Specifications Maximum peak amplitude allowwed for overshoot 1.5 V Maximum peak amplitude allowwed for undershoot 1.5 V The area between the overshoot signal and VDD must be less than or equal to(See below Fig) 4.5 V-nS The area between the overshoot signal and GND must be less than or equal to(See below Fig) 4.5 V-nS +5 Volt (v) + 4 Max. Amplitude = 1.5v +3 VDD +2 +1 Ground 0 -1 Max. area = 4.5v-nS -2 -3 0 1 2 3 Time(nS) 4 5 6 AC Overshoot/Undershoot specifications for Data, Strobe and Mask Pins Parameter Specifications Maximum peak amplitude allowwed for overshoot 1.2 V Maximum peak amplitude allowwed for undershoot 1.2 V The area between the overshoot signal and VDD must be less than or equal to(See below Fig) 2.4 V-nS The area between the overshoot signal and GND must be less than or equal to(See below Fig) 2.4 V-nS +5 Volt (v) + 4 Max. Amplitude = 1.2v +3 VDD +2 +1 Ground 0 -1 Max. area = 2.4 v-nS -2 -3 0 Rev. 0.7 / Jun. 2004 1 2 3 4 Time(nS) 5 6 24 HY5DU283222AF AC CHARACTERISTICS - I (AC operating conditions unless otherwise noted) Parameter Symbol 2 22 25 Unit Min Max Min Max Min Max Row Cycle Time tRC 23 - 21 - 18 - CK Auto Refresh Row Cycle Time tRFC 26 - 24 - 21 - CK Row Active Time tRAS 16 100K 14 100K 12 100K CK Row Address to Column Address Delay for Read tRCDRD 7 - 7 - 6 - CK Row Address to Column Address Delay for Write tRCDWR 4 - 3 - 3 - CK Row Active to Row Active Delay tRRD 4 - 4 - 4 - CK Column Address to Column Address Delay tCCD 2 - 2 - 1 - CK Row Precharge Time tRP 7 - 7 - 6 - CK Write Recovery Time tWR 4 - 4 - 3 - CK Last Data-In to Read Command tDRL 2 - 2 - 2 - CK Auto Precharge Write Recovery + Precharge Time tDAL 11 - 11 - 9 - CK 2 6 2.2 6 2.5 6 ns - - - - - - ns System Clock Cycle Time CL=5 CL=4 tCK Note Clock High Level Width tCH 0.45 0.55 0.45 0.55 0.45 0.55 CK Clock Low Level Width tCL 0.45 0.55 0.45 0.55 0.45 0.55 CK Data-Out edge to Clock edge Skew tAC -0.45 0.45 -0.45 0.45 -0.6 0.6 ns DQS-Out edge to Clock edge Skew tDQSCK -0.45 0.45 -0.45 0.45 -0.6 0.6 ns DQS-Out edge to Data-Out edge Skew tDQSQ - 0.25 - 0.35 - 0.35 ns Data-Out hold time from DQS tQH tHPmin -tQHS - tHPmin -tQHS - tHPmin -tQHS - ns 1,6 Clock Half Period tHP tCH/L min - tCH/L min - tCH/L min - ns 1,5 tQHS - 0.25 - 0.35 - 0.35 ns 6 Input Setup Time tIS 0.6 - 0.75 - 0.75 - ns 2 Input Hold Time tIH 0.6 - 0.75 - 0.75 - ns 2 Write DQS High Level Width tDQSH 0.45 0.55 0.4 0.6 0.4 0.6 CK Write DQS Low Level Width tDQSL 0.45 0.55 0.4 0.6 0.4 0.6 CK Clock to First Rising edge of DQS-In tDQSS 0.85 1.15 0.85 1.15 0.85 1.15 CK Data-In Setup Time to DQS-In (DQ & DM) tDS 0.35 - 0.35 - 0.35 - ns 3 Data-In Hold Time to DQS-In (DQ & DM) tDH 0.35 - 0.35 - 0.35 - ns 3 tDSS 0.3 - 0.3 - 0.3 - CK Data Hold Skew Factor DQS falling edge to CK setup time Rev. 0.7 / Jun. 2004 25 HY5DU283222AF Parameter Symbol 2 22 25 Unit Min Max Min Max Min Max DQS falling edge hold time from CK tDSH 0.3 - 0.3 - 0.3 - CK Read DQS Preamble Time tRPRE 0.9 1.1 0.9 1.1 0.9 1.1 CK Read DQS Postamble Time tRPST 0.4 0.6 0.4 0.6 0.4 0.6 CK Write DQS Preamble Setup Time tWPRES 0 - 0 - 0 - ns Write DQS Preamble Hold Time tWPREH 0.35 - 0.35 - 0.35 - CK Write DQS Postamble Time tWPST 0.4 0.6 0.4 0.6 0.4 0.6 CK Mode Register Set Delay tMRD 2 - 2 - 2 - CK Exit Self Refresh to Any Execute Command tXSC 200 - 200 - 200 - CK Power Down Exit Time tPDEX 2tCK + tIS - 2tCK + tIS - 2tCK + tIS - CK Average Periodic Refresh Interval tREFI - 7.8 - 7.8 - 7.8 us Note 4 Note : 1. This calculation accounts for tDQSQ(max), the pulse width distortion of on-chip circuit and jitter. 2. Data sampled at the rising edges of the clock : A0~A11, BA0~BA1, CKE, /CS, /RAS, /CAS, /WE. 3. Data latched at both rising and falling edges of Data Strobes(DQS0~DQS3) : DQ, DM(0~3). 4. Minimum of 200 cycles of stable input clocks after Self Refresh Exit command, where CKE is held high, is required to complete Self Refresh Exit and lock the internal DLL circuit of DDR SDRAM. 5. Min (tCL, tCH) refers to the smaller of the actual clock low time and the actual clock high time as provided to the device (i.e. this value can be greater than the minimum specification limits for tCL and tCH). 6. tHP = minimum half clock period for any given cycle and is defined by clock high or clock low (tCH, tCL). tQHS consists of tDQSQmax, the pulse width distortion of on-chip clock circuits, data pin to pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers. 7. DQS, DM and DQ input slew rate is specified to prevent double clocking of data and preserve setup and hold times. Signal transitions through the DC region must be monotonic. Rev. 0.7 / Jun. 2004 26 HY5DU283222AF AC CHARACTERISTICS - I (continue) Parameter 28 Symbol 33 4 36 5 Unit Min Max Min Max Min Max Min Max Min Max Row Cycle Time tRC 16 - 14 - 14 - 13 - 10 - CK Auto Refresh Row Cycle Time tRFC 17 - 17 - 16 - 15 - 12 - CK Row Active Time tRAS 10 100K 9 100K 9 100K 8 100K 7 100K CK Row Address to Column Address Delay for Read tRCDRD 5 - 5 - 5 - 5 - 4 - CK Row Address to Column Address Delay for Write tRCDWR 2 - 2 - 2 - 2 - 2 - CK Row Active to Row Active Delay tRRD 4 - 3 - 3 - 3 - 2 - CK Column Address to Column Address Delay tCCD 1 - 1 - 1 - 1 - 1 - CK Row Precharge Time tRP 5 - 5 - 5 - 5 - 4 - CK Write Recovery Time tWR 3 - 3 - 3 - 3 - 2 - CK Last Data-In to Read Command tDRL 2 - 2 - 2 - 2 - 2 - CK Auto Precharge Write Recovery + Precharge Time tDAL 8 - 8 - 8 - 7 - 6 - CK - - - - - - - - - - ns 2.8 6 3.3 10 3.6 10 4 10 - - ns - - 4.5 10 4.5 10 4.5 10 5 10 ns CL=5 System Clock Cycle Time CL=4 tCK CL=3 Note Clock High Level Width tCH 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 CK Clock Low Level Width tCL 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 CK Data-Out edge to Clock edge Skew tAC -0.6 0.6 -0.6 0.6 -0.6 0.6 -0.6 0.6 -0.6 0.6 ns DQS-Out edge to Clock edge Skew tDQSCK -0.6 0.6 -0.6 0.6 -0.6 0.6 -0.6 0.6 -0.6 0.6 ns DQS-Out edge to DataOut edge Skew tDQSQ - 0.35 - 0.35 - 0.4 - 0.4 - 0.4 ns Data-Out hold time from DQS tQH tHPmin -tQHS - tHPmin -tQHS - tHPmin -tQHS - tHPmin -tQHS - tHPmin -tQHS - ns 1,6 Clock Half Period tHP tCH/L min - tCH/L min - tCH/L min - tCH/L min - tCH/L min - ns 1,5 tQHS - 0.35 - 0.35 - 0.4 - 0.4 - 0.4 ns 6 Data Hold Skew Factor Rev. 0.7 / Jun. 2004 27 HY5DU283222AF Parameter 28 Symbol 33 4 36 5 Min Max Min Max Min Max Min Max Min Max Unit Note Input Setup Time tIS 0.75 - 0.75 - 0.75 - 0.75 - 0.75 - ns 2 Input Hold Time tIH 0.75 - 0.75 - 0.75 - 0.75 - 0.75 - ns 2 Write DQS High Level Width tDQSH 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 CK Write DQS Low Level Width tDQSL 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 CK Clock to First Rising edge of DQS-In tDQSS 0.85 1.15 0.85 1.15 0.85 1.15 0.85 1.15 0.85 1.15 CK Data-In Setup Time to DQS-In (DQ & DM) tDS 0.35 - 0.35 - 0.4 - 0.4 - 0.45 - ns 3 Data-In Hold Time to DQS-In (DQ & DM) tDH 0.35 - 0.35 - 0.4 - 0.4 - 0.45 - ns 3 DQS falling edge to CK setup time tDSS 0.3 - 0.3 - 0.3 - 0.3 - 0.3 - CK DQS falling edge hold time from CK tDSH 0.3 - 0.3 - 0.3 - 0.3 - 0.3 - CK Read DQS Preamble Time tRPRE 0.9 1.1 0.9 1.1 0.9 1.1 0.9 1.1 0.9 1.1 CK Read DQS Postamble Time tRPST 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 CK Write DQS Preamble Setup Time tWPRES 0 - 0 - 0 - 0 - 0 - ns Write DQS Preamble Hold Time tWPREH 0.35 - 0.35 - 0.35 - 0.35 - 0.35 - CK Write DQS Postamble Time tWPST 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 CK Mode Register Set Delay tMRD 2 - 2 - 2 - 2 - 2 - CK Exit Self Refresh to Any Execute Command tXSC 200 - 200 - 200 - 200 - 200 - CK Power Down Exit Time tPDEX 2tCK + tIS - 2tCK + tIS - 1tCK + tIS - 1tCK + tIS - 1tCK + tIS - CK Average Periodic Refresh Interval tREFI - 7.8 - 7.8 - 7.8 - 7.8 - 7.8 us 4 Note : 1. This calculation accounts for tDQSQ(max), the pulse width distortion of on-chip circuit and jitter. 2. Data sampled at the rising edges of the clock : A0~A11, BA0~BA1, CKE, /CS, /RAS, /CAS, /WE. 3. Data latched at both rising and falling edges of Data Strobes(DQS0~DQS3) : DQ, DM(0~3). 4. Minimum of 200 cycles of stable input clocks after Self Refresh Exit command, where CKE is held high, is required to complete Self Refresh Exit and lock the internal DLL circuit of DDR SDRAM. Rev. 0.7 / Jun. 2004 28 5. Min (tCL, tCH) refers to the smaller of the actual clock low time and the actual clock high time as provided to the device (i.e. this value can be greater than the minimum specification limits for tCL and tCH). 6. tHP = minimum half clock period for any given cycle and is defined by clock high or clock low (tCH, tCL). tQHS consists of tDQSQmax, the pulse width distortion of on-chip clock circuits, data pin to pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers. 7. DQS, DM and DQ input slew rate is specified to prevent double clocking of data and preserve setup and hold times. Signal transitions through the DC region must be monotonic. HY5DU283222AF AC CHARACTERISTICS - II Frequency CL tRC tRFC tRAS tRCDRD tRCDWR tRP tDAL Unit 500MHz (2ns) 5 23 26 16 7 4 7 11 tCK 450MHz (2.2ns) 5 21 24 14 7 3 7 11 tCK 400MHz (2.5ns) 5 18 21 12 6 3 6 9 tCK 350MHz (2.8ns) 4 16 17 10 5 2 5 8 tCK 300MHz (3.3ns) 4 14 17 9 5 2 5 8 tCK 275MHz (3.6ns) 4 14 16 9 5 2 5 8 tCK 250MHz (4ns) 4 13 15 8 5 2 5 7 tCK 200MHz (5ns) 3 10 12 7 4 2 4 6 tCK Rev. 0.7 / Jun. 2004 30 HY5DU283222AF CAPACITANCE (TA=25oC, f=1MHz ) Parameter Pin Symbol Min Max Unit Input Clock Capacitance CK, /CK CCK 1 3 pF Input Capacitance All other input-only pins CIN 1 3 pF Input / Output Capacitance DQ, DQS, DM CIO 3 5 pF Note : 1. VDD = min. to max., VDDQ = 2.3V to 2.7V, VODC = VDDQ/2, VOpeak-to-peak = 0.2V 2. Pins not under test are tied to GND. 3. These values are guaranteed by design and are tested on a sample basis only. OUTPUT LOAD CIRCUIT V TT R T =50Ω Output Zo=50Ω V REF C L=30pF Rev. 0.7 / Jun. 2004 31 HY5DU283222AF PACKAGE INFORMATION 12mm x 12mm, 144ball Fine-pitch Ball Grid Array 12mm± 0.1 1.2 mm max 0.76mm ± 0.05 12mm± 0.1 Detailed “A” 8.8mm 0.35mm ± 0.05 0.8mm Detailed “A” 8.8mm 0.12mm 0.5mm Diameter 0.55Max 0.45Min [ Ball Location ] Ball existing Optional (Vss thermal ball) Rev. 0.7 / Jun. 2004 32