ETC B82790

Data downloaded from http://www.angliac.com - the website of Anglia - tel: 01945 474747
Chokes for Data and Signal Lines
B82790C0*/K0*N2
Double Chokes
B82790S0*/L0*N2
Rated voltage 42 VAC/80 DC
Rated current 200 to 1000 mA
Rated inductance 5 mH to 4,7 mH
Construction
■ Current-compensated ring core choke with ferrite core
■ Bifilar winding (B82790C0*/K0*)
■ Sector winding (B82790S0*/L0*)
Features
■ Case flame-retardant as per UL 94 V-0
■ Suitable for reflow soldering
Special types for conductive adhesion
and ambient temperatures up to 150°C on request
Applications
■ B82790C0*/K0*:
Suppression of asymmetrical interference coupled in on lines,
whereas data signals up to some MHz can pass unaffectedly
■ B82790S0*/L0*:
Suppression of asymmetrical and symmetrical interference
coupled in on lines. The high-frequency portions of the symmetrical
data signal are decreased so far that EMC problems can be
significantly reduced.
Terminals
■ Lead-free tinned
Marking
Manufacturer, ordering code (short form),
date of manufacture, coded (year, day of week, calender week)
Delivery mode
Blister tape, reel packing
For details on taping, packing and packing units see data book 2000
"Chokes and Inductors", page 302
1
06/02
For the very latest product data and news visit angliac.com
Data downloaded from http://www.angliac.com - the website of Anglia - tel: 01945 474747
Chokes for Data and Signal Lines
B82790C0*/K0*N2
Double Chokes
B82790S0*/L0*N2
Dimensional drawing
0,25±0,05
0,25±0,1
5,2 max.
4,9 max.
0...6
0,6±0,05
2,5±0,1
1,9±0,2
6,0 max.
A
max. 0,08 A
Marking
7,1 max.
_ 0,2
9 +0,4
IND0009-B-E
Layout recommendation
2,85
2,5
1,2
(4,5)
10,2
IND0163-B
2
06/02
For the very latest product data and news visit angliac.com
Data downloaded from http://www.angliac.com - the website of Anglia - tel: 01945 474747
Chokes for Data and Signal Lines
B82790C0*/K0*N2
Double Chokes
B82790S0*/L0*N2
Technical data and measuring conditions
Rated voltage V R
42 VAC (50/60 Hz)
80 VDC
Rated current IR
Referred to 50 Hz and 60 °C ambient temperature
Rated inductance L R
Measured with HP 4275A
at L ≤ 1 mH = 100 kHz, 0,1 mA
L > 1 mH = 10 kHz, 0,1 mA
(specified per winding)
Inductance tolerance
L ≤ 0,47 mH: ± 30 %
L > 0,47 mH: – 30/+ 50 %
Inductance decrease ∆L/L0
< 10 % at dc magnetic bias with IR
Stray inductance LS
Measured with HP 4275A.
Measuring frequency at L ≤ 11 µH = 1 MHz, 5 mA
L > 11 µH = 100 kHz, 5 mA
DC resistance R typ
Typical values, measured at 20 °C ambient temperature
Solderability
(215 ± 3) °C, (3 ± 0,3) s
wetting of soldering area ≥ 95 %
in accordance with IEC 60068-2-58
Climatic category
40/125/56 (– 40 °C/+ 125 °C/56 days damp heat test)
in accordance with IEC 60068-1
Weight
Approx. 0,3 g
Characteristics and ordering codes
LR
mH
LS, typ
nH
IR
mA
VT
VDC, 2 s
Rtyp
mΩ
Ordering code 1)
0,005
50
1000
100
250
B82790C0502N201
0,011
50
500
120
250
B82790C0113N201
0,025
150
500
130
250
B82790C0253N201
0,025
1500
500
130
250
B82790S0253N201
0,051
200
500
160
250
B82790C0513N201
0,051
2000
500
160
250
B82790S0513N201
0,470
200
500
200
750
B82790C0474N215
1,0
250
500
200
750
B82790C0105N240
2,2
250
400
400
750
B82790C0225N265
4,7
300
200
550
750
B82790C0475N265
1) Special types for conductive adhesion and ambient temperatures of up to 150 °C upon request.
3
06/02
For the very latest product data and news visit angliac.com
Data downloaded from http://www.angliac.com - the website of Anglia - tel: 01945 474747
Chokes for Data and Signal Lines
B82790C0*/K0*N2
Double Chokes
B82790S0*/L0*N2
Insertion loss ae (typical values at Z = 50 Ω)
asymmetrical, all branches in parallel (common mode)
symmetrical (differential mode)
L R = 0,005 mH
LR = 0,011 mH
IND0013-6
50
dB
dB
40
40
30
30
20
20
10
10
10 6
10 7
10 8
0 5
10
Hz 10 9
f
L R = 0,025 mH (low LS)
10 7
10 8
Hz 10 9
f
IND0015-W
50
B82790C0253N201
dB
B82790S0253N201
αe
αe
40
40
30
30
20
20
10
10
0 5
10
10 6
LR = 0,025 mH (high L S)
IND0011-4
50
dB
B82790C0113N201
αe
αe
0 5
10
IND0014-8
50
B82790C0502N201
10 6
10 7
10 8
0 5
10
Hz 10 9
f
4
06/02
10 6
10 7
10 8
For the very latest product data and news visit angliac.com
Hz 10 9
f
Data downloaded from http://www.angliac.com - the website of Anglia - tel: 01945 474747
Chokes for Data and Signal Lines
B82790C0*/K0*N2
Double Chokes
B82790S0*/L0*N2
Insertion loss ae (typical values at Z = 50 Ω)
asymmetrical, all branches in parallel (common mode)
symmetrical (differential mode)
L R = 0,051 mH (low LS)
LR = 0,051 mH (high L S)
IND0012-V
50
dB
IND0016-9
50
B82790C0513N201
dB
αe
B82790S0513N201
αe
40
40
30
30
20
20
10
10
0 5
10
10 6
10 7
10 8
0 5
10
Hz 10 9
f
L R = 0,47 mH
10 7
10 8
Hz 10 9
f
LR = 1,0 mH
IND0017-H
50
dB
10 6
50
dB
B82790C0474N215
IND0018-R
B82790C0105N240
αe
αe
40
40
30
30
20
20
10
10
0 4
10
10 5
10 6
10 7
0
10 4
Hz 10 8
f
5
06/02
10 5
10 6
10 7 Hz 10 8 3
f
For the very latest product data and news visit angliac.com
Data downloaded from http://www.angliac.com - the website of Anglia - tel: 01945 474747
Chokes for Data and Signal Lines
B82790C0*/K0*N2
Double Chokes
B82790S0*/L0*N2
Insertion loss ae (typical values at Z = 50 Ω)
asymmetrical, all branches in parallel (common mode)
symmetrical (differential mode)
L R = 2,2 mH
LR = 4,7 mH
IND0019-1
50
dB
B82790C0225N265
dB
B82790C0475N265
αe
αe
40
40
30
30
20
20
10
10
0 4
10
IND0020-Z
50
10 5
10 6
10 7 Hz 10 8
f
0 4
10
4
10 5
10 6
10 7
Hz 10 8
f
Published by EPCOS AG
Corporate Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
++49 89 636 09, FAX (0 89) 636-2 26 89
(
 EPCOS AG 2002. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of
the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic
Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
6
06/02
For the very latest product data and news visit angliac.com