MSFC12-83-026K0 MSFC12-85-026K1 MSFB12-85-026K0 AMPS-IF ■Features ¡IF filter for AMPS. ¡Because it is leadless type, automatic mounting is possible. ¡Excellent group delay distortion characteristics. ■Standard Frequencies ¡83.16MHz. ¡85.38MHz. ■Specifications MSFC12-85-026K1 MSFB12-85-02640 MSFC12-83-026K0 Type Item Unit Conditions Specifications Conditions Specifications Nominal Frequency MHz –––––– 83.16 –––––– 85.38 Operating Temperature Range : –25~+75 –––––– –30~+80 –––––– Storage Temperature Range : –35~+85 –––––– –40~+85 –––––– Pass Bandwidth kHz –3dB Fo±13 MIN. –3dB Fo±13 MIN. Ripple dB Fo±13kHz 1.5 MAX. Fo±10kHz 1.5 MAX. Insertion Loss dB Minimum Loss 5.0 MAX. Minimum Loss 5.0 MAX. Fo–120kHz 50 MIN. Fo–120kHz 40 MIN. dB Guaranteed Attenuation Fo±60kHz 25 MIN. Fo±60kHz 25 MIN. Fo+120kHz 50 MIN. Fo+120kHz 40 MIN. Fo±10kHz 12 MAX. MSFC12 980//–1.2 MSFB12 1450//–1.6 Group Delay Deviation µS Fo±13kHz 10 MAX. Terminating Impedance Ω//pF –––––– 810//–1.5 ■Outline ■Measurement Circuit MSFC12 MSFB12 7.00±0.2 6 83.16 0J KSS 10 1 2 5 4 Type H (mm) MSFC12 1.8 MAX. MSFB12 2.0 MAX. 8 L1 SSG 0.60 2.54 4 9 5 7 6 CONNECTION 6:GND 1:GND 7:GND 2:GND 8:GND 3:GND 9:GND 4:GND 5:OUT(IN) 10:IN(OUT) Dimensions(mm) 50Ω 1.27 3 1.8 2 10 8 6 L2 H 1.27 1 7 3 L2 C1 9 85.38 0J KSS 10 1 2 3 L4 5 4 C3 Volt meter 9 7 50Ω 5.00±0.2 8