MITEL MT9171AN


ISO2-CMOS ST-BUS FAMILY MT9171/72
Digital Subscriber Interface Circuit
Digital Network Interface Circuit
Features
ISSUE 1
•
Full duplex transmission over a single twisted
pair
•
Selectable 80 or 160 kbit/s line rate
•
Adaptive echo cancellation
•
Up to 3km (9171) and 4 km (9172)
•
ISDN compatible (2B+D) data format
•
Transparent modem capability
•
Frame synchronization and clock extraction
•
MITEL ST-BUS compatible
•
Low power (typically 50 mW), single 5V supply
Ordering Information
MT9171AE
22 Pin Plastic DIP
MT9172AE
22 Pin Plastic DIP
MT9172AC
22 Pin Ceramic DIP
MT9171AN
24 Pin SSOP
MT9172AN
24 Pin SSOP
MT9171AP
28 Pin PLCC
MT9172AP
28 Pin PLCC
-40°C to + 85°C
a twisted wire pair.
They use adaptive echocancelling techniques and transfer data in (2B+D)
format compatible to the ISDN basic rate. Several
modes of operation allow an easy interface to digital
telecommunication networks including use as a high
speed limited distance modem with data rates up to
160 kbit/s. Both devices function identically but with
the DSIC having a shorter maximum loop reach
specification. The generic "DNIC" will be used to
reference both devices unless otherwise noted.
Applications
•
Digital subscriber lines
•
High speed data transmission over twisted
wires
•
Digital PABX line cards and telephone sets
•
80 or 160 kbit/s single chip modem
May 1995
The MT9171/72 is fabricated in Mitel’s ISO2-CMOS
process.
Description
The MT9171 (DSIC) and MT9172 (DNIC) are multifunction devices capable of providing high speed,
full duplex digital transmission up to 160 kbit/s over
DSTi/Di
CDSTi/
CDi
F0/CLD
C4/TCK
F0o/RCK
MS0
MS1
MS2
Transmit
Interface
Control
Register
Prescrambler
Transmit
Filter &
Line Driver
LOUT
LOUT
DIS
VBias
Transmit
Timing
Master Clock
Phase Locked
Transmit/
Clock
Receive
Timing &
Control
Sync Detect
Differentially
Encoded Biphase
Transmitter
Scrambler
Address
Echo Canceller
Error
Signal
Echo Estimate
MUX
Precan
—
∑
DPLL
+
Receive
Filter
-1
+2
LIN
RegC
Status
Receive
OSC2
DSTo/Do
CDSTo/
CDo
Receive
Interface
DePrescrambler
Descrambler
VDD
VSS
Differentially
Encoded Biphase
Receiver
OSC1
VBias VRef
Figure 1 - Functional Block Diagram
9-133
MT9171/72
4
3
2
1
28
27
26
VDD
LIN
TEST
LOUT DIS
Precan
OSC1
OSC2
C4/TCK
F0o/RCK
DSTi/Di
DSTo/Do
22 PIN PDIP/CERDIP
LOUT
VBias
VRef
MS2
MS1
MS0
RegC
NC
F0/CLD
CDSTi/CDi
CDSTo/CDo
VSS
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
VDD
LIN
TEST
LOUT DIS
Precan
OSC1
NC
OSC2
C4/TCK
F0o/RCK
DSTi/Di
DSTo/Do
5
6
7
8
9
10
11
•
12
13
14
15
16
17
18
MS2
NC
MS1
MS0
RegC
F0/CLD
NC
25
24
23
22
21
20
19
NC
LOUT DIS
Precan
OSC1
OSC2
NC
C4/TCK
CDSTi/CDi
CDSTo/CDo
VSS
DSTo/Do
DSTi/Di
F0o/RCK
NC
22
21
20
19
18
17
16
15
14
13
12
1
2
3
4
5
6
7
8
9
10
11
LOUT
VBias
VRef
MS2
MS1
MS0
RegC
F0/CLD
CDSTi/CDi
CDSTo/CDo
VSS
VRef
VBias
LOUT
NC
VDD
LIN
TEST
Advance Information
28 PIN PLCC
24 PIN SSOP
Figure 2 - Pin Connections
Pin Description
Pin #
Name
Description
22
24
28
1
1
2
LOUT
Line Out. Transmit Signal output (Analog). Referenced to VBias.
2
2
3
VBias
Internal Bias Voltage output. Connect via 0.33 µF decoupling capacitor to VDD.
3
3
4
VRef
Internal Reference Voltage output. Connect via 0.33 µF decoupling capacitor to
VDD.
4,5, 4,5,
6
6
5,7,
8
MS2-MS0 Mode Select inputs (Digital). The logic levels present on these pins select the
various operating modes for a particular application. See Table 1 for the
operating modes.
7
7
9
RegC
Regulator Control output (Digital). A 512 kHz clock used for switch mode power
supplies. Unused in MAS/MOD mode and should be left open circuit.
8
9
10
F0/CLD
Frame Pulse/C-Channel Load (Digital). In DN mode a 244 ns wide negative
pulse input for the MASTER indicating the start of the active channel times of the
device. Output for the SLAVE indicating the start of the active channel times of
the device. Output in MOD mode providing a pulse indicating the start of the Cchannel.
9
10
12
CDSTi/
CDi
Control/Data ST-BUS In/Control/Data In (Digital). A 2.048 Mbit/s serial control
& signalling input in DN mode. In MOD mode this is a continuous bit stream at
the bit rate selected.
10
11
13
CDSTo/
CDo
Control/Data ST-BUS Out/Control/Data Out (Digital). A 2.048 Mbit/s serial
control & signalling output in DN mode. In MOD mode this is a continuous bit
stream at the bit rate selected.
9-134
MT9171/72
Advance Information
Pin Description (continued)
Pin #
Name
Description
22
24
28
11
12
14
12
13
15
DSTo/Do Data ST-BUS Out/Data Out (Digital). A 2.048 Mbit/s serial PCM/data output in
DN mode. In MOD mode this is a continuous bit stream at the bit rate selected.
13
14
16
DSTi/Di
14
15
17
F0o/RCK Frame Pulse Out/Receive Bit Rate Clock output (Digital). In DN mode a 244 ns
wide negative pulse indicating the end of the active channel times of the device
to allow daisy chaining. In MOD mode provides the receive bit rate clock to the
system.
15
16
19
C4/TCK
16
17
21
OSC2
Oscillator Output. CMOS Output.
17
19
22
OSC1
Oscillator Input. CMOS Input. D.C. couple signals to this pin. Refer to D.C.
Electrical Characteristics for OSC1 input requirements.
18
20
23
Precan
Precanceller Disable. When held to Logic ’1’, the internal path from LOUT to the
precanceller is forced to VBias thus bypassing the precanceller section. When
logic ’0’, the LOUT to the precanceller path is enabled and functions normally. An
internal pulldown (50 kΩ) is provided on this pin.
8,
18
1,6,
11,
18,
20,
25
NC
19
21
24
20
22
26
TEST
21
23
27
LIN
Receive Signal input (Analog).
22
24
28
VDD
Positive Power Supply (+5V) input.
VSS
Negative Power Supply (0V).
Data ST-BUS In/Data In (Digital). A 2.048 Mbit/s serial PCM/data input in DN
mode. In MOD mode this is a continuous bit stream at the bit rate selected.
Data Clock/Transmit Baud Rate Clock (Digital). A 4.096 MHz TTL compatible
clock input for the MASTER and output for the SLAVE in DN mode. For MOD
mode this pin provides the transmit bit rate clock to the system.
No Connection. Leave open circuit
LOUT DIS LOUT Disable. When held to logic “1”, LOUT is disabled (i.e., output = VBias). When
logic “0”, LOUT functions normally. An internal pulldown (50 kΩ) is provided on this
pin.
Test Pin.
Connect to VSS.
9-135
MT9171/72
Advance Information
F0
C4
DSTi
DSTo
A AA
AAAA
AAAAA
A
AAAA
A
AA
A
A B17
AAAA
A
AA
A
AAAA
A
AA
AAAA
A
A
AA
AAAA
A
AA
A
AAAA
AA
A
AAAAA
AA
AA
AAAAA
AA
AAAAA
AA
A B17
AAAAA
AA
AAAA
AAAA
AA
AA
AAAA
A
AAAA
AA
AAAA
AA
A
B16
B15
B14
B13
B12
B11
B10
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA B17
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
B16
B15
B14
B13
B12
B11
B10
AAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA B17
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
F0o
Channel Time 0
Figure 3 - DV Port - 80 kbit/s (Modes 2, 3, 6)
F0
C4
DSTi
AA
AAAA
AA
AAAA
AA
AA
AA
AA
AAAA
AAAA
AA
AA
AAAAAA B17 B16 B15 B14
AA
AAAA
AA
AAAAAA
AA
AAAAAA
AA
AAAA
AA AAA
AAAA
AA
AAAAAAAA
AAAAAAAA
AAAA
AAA
AAAAAAAA
AAAAAAAA
AAAA
AA AAAA
AAAA B1
AA AAA
AA
B13 B12 B11 B10AAAA
AAAAAAAA
AAAAAAAA
AAAA
AAA B27 B26 B25 B24 B23 B22 B21 B20AAAA
AAAAAAAA
AAAAAAAA
AAAA
AA AAAA
AAAA 7
AAAA
AAAA
AAAA
A
AAA
AAAA
AAAA
AAAA
AA
AAAAAAAAAAAA
A AAA
AAAAAAAAAAAA
AA AAAA
AAAA
DSTo
AA
AAAA
AAAAAA
AAAAAA
AA
AA
AAAA
AA
AAAAAA
AA
AA B17 B16 B15 B14
AAAA
AA
AAAAAA
AA
AAAAAA
AA
AAAA
AA AAA
AAAA
AA
AAAAAAAA
AAAAAAAA
AAAA
AAA
AAAAAAAA
AAAAAAAA
AAAA
AA AAAA
AAAA
AA AAA
AA
B13 B12 B11 B10AAAA
AAAAAAAA
AAAAAAAA
AAAA
AAA B27 B26 B25 B24 B23 B22 B21 B20AAAA
AAAAAAAA
AAAAAAAA
AAAA
AA AAAA
AAAA B17
AAAA
AAAA
AAAA
A
AAA
AAAA
AAAA
AAAA
AA
AAAAAAAAAAAA
A AAA
AAAAAAAAAAAA
AA AAAA
AAAA
F0o
Channel Time 0
Channel Time 16
Figure 4 - DV Port - 160 kbit/s (Modes 2, 3, 6)
9-136
Advance Information
Functional Description
The MT9171/72 is a device which has been
designed primarily as an interface for the Integrated
Services Digital Network (ISDN). However, it may be
used in practically any application that requires high
speed data transmission over two wires, including
smart telephone sets, workstations, data terminals
and computers.
In the ISDN, the DNIC is ideal for providing the
interface at the U reference point. The device
supports the 2B+D channel format (two 64 kbit/s Bchannels and one 16 kbit/s D-channel) over two
wires as recommended by the CCITT. The line data
is converted to and from the ST-BUS format on the
system side of the network to allow for easy
interfacing with other components such as the Sinterface device in an NT1 arrangement, or to digital
PABX components.
Smart telephone sets with data and voice capability
can be easily implemented using the MT9171/72 as
a line interface. The device’s high bandwidth and
long loop length capability allows its use in a wide
variety of sets. This can be extended to provide full
data and voice capability to the private subscriber by
the installation of equipment in both the home and
central office or remote concentration equipment.
Within the subscriber equipment the MT9171/72
would terminate the line and encode/ decode the
data and voice for transmission while additional
electronics could provide interfaces for a standard
telephone set and any number of data ports
supporting standard data rates for such things as
computer communications and telemetry for remote
meter reading. Digital workstations with a high
degree of networking capability can be designed
using the DNIC for the line interface, offering up to
160 kbit/s data transmission over existing telephone
lines. The MT9171/72 could also be valuable within
existing computer networks for connecting a large
number of terminals to a computer or for
intercomputer links. The highest data rates existing
for terminal to computer links is 19.2 kbit/s over
conventional analog modems. With the DNIC, this
can be increased up to 160 kbit/s at a very low cost
per line for terminal to computer links and in many
cases this bandwidth would be sufficient for
computer to computer links.
Figure 1 shows the block diagram of the MT9171/72.
The DNIC provides a bidirectional interface between
the DV (data/voice) port and a full duplex line
operating at 80 or 160 kbit/s over a single pair of
twisted wires. The DNIC has three serial ports. The
DV port (DSTi/Di, DSTo/Do), the CD (control/data)
port (CDSTi/CDi, CDSTo/CDo) and a line port (LIN,
MT9171/72
LOUT). The data on the line is made up of information
from the DV and CD ports. The DNIC must combine
information received from both the DV and CD ports
and put it onto the line. At the same time, the data
received from the line must be split into the various
channels and directed to the proper ports. The
usable data rates are 72 and 144 kbit/s as required
for the basic rate interface in ISDN. Full duplex
transmission is made possible through on board
adaptive echo cancellation.
The DNIC has various modes of operation which are
selected through the mode select pins MS0-2. The
two major modes of operation are the MODEM
(MOD) and DIGITAL NETWORK (DN) modes. MOD
mode is a transparent 80 or 160 kbit/s modem. In
DN mode the line carries the B and D channels
formatted for the ISDN at either 80 or 160 kbit/s. In
the DN mode the DV and CD ports are standard STBUS and in MOD mode they are transparent serial
data streams at 80 or 160 kbit/s. Other modes
include: MASTER (MAS) or SLAVE (SLV) mode,
where the timebase and frame synchronization are
provided externally or are extracted from the line and
DUAL or SINGLE (SINGL) port modes, where both
the DV and CD ports are active or where the CD port
is inactive and all information is passed through the
DV port. For a detailed description of the modes see
“Operating Modes” section.
In DIGITAL NETWORK (DN) mode there are three
channels transferred by the DV and CD ports. They
are the B, C and D channels. The B1 and B2
channels each have a bandwidth of 64 kbit/s and are
used for carrying PCM encoded voice or data. These
channels are always transmitted and received
through the DV port (Figures 3, 4, 5, 6). The Cchannel, having a bandwidth of 64 kbit/s, provides a
means for the system to control the DNIC and for the
DNIC to pass status information back to the system.
The C-channel has a Housekeeping (HK) bit which is
the only bit of the C-channel transmitted and
received on the line. The 2B+D channel bits and the
HK bit are double-buffered. The D-channel can be
transmitted or received on the line with either an 8,
16 or 64 kbit/s bandwidth depending on the DNIC’s
mode of operation. Both the HK bit and the Dchannel can be used for end-to-end signalling or low
speed data transfer. In DUAL port mode the C and D
channels are accessed via the CD port (Figure 7)
while in SINGL port mode they are transferred
through the DV port (Figures 5, 6) along with the B1
and B2 channels.
9-137
MT9171/72
Figure 6 - DV Port - 160 kbit/s (Modes 0,4)
Channel Time 3
B2-Channel
Channel Time 2
B1-Channel
Channel Time 1
C-Channel
Channel Time 0
D-Channel
15.6 µsec
F0o
C4
F0
D0
AAAA
AA
AAAA
AA
AAAA
AA
AAAA
AA
AAAA
AAAAAA
AA
D0 D1 D2 D3 D4 D5 D6 D7 C0 C1 C2 C3 C4 C5 C6 C7 B7 B6 B5 B4 B3 B2 B1 B0 B7 B6 B5 B4 B3 B2 B1 B0
AAAA
AA
AAAA
AAAA
AA
AAAA
AAAA
AAAAAA
DSTi
D0
AAAAAA
AAAA
AAAAAA
AA
AAAAAA
AAAAAA
AAAA
AA
AAAA
AAAAAA
AA
AAAA
AAAAAA
AA
AAAAAA
AAAA
AAAAAA
AA
AAAAAA
AAAAAA
AAAA
AAAAAA
AA
AAAAAA
D0 D1 D2 D3 D4 D5 D6 D7 C0 C1 C2 C3 C4 C5 C6 C7 B7 B6 B5 B4 B3 B2 B1 B0 B7 B6 B5 B4 B3 B2 B1 B0
AAAAA
AAAA
AAAAAA
AAAAA
AAAAA
AAAA
A
AAAA
AAAAAA
AAAA
AAAAAA
AAAAA
AAAA
AAAAAA
AAAAA
AAAAA
AAAA
AAAAAA
AAAAA
DSTo
Figure 5 - DV Port - 80 kbit/s (Modes 0,4)
Channel Time 2
B1-Channel
F0o
Channel Time 0
D-Channel
11.7 µsec
Channel Time 1
C-Channel
AAAA
A
AAAA
A
AAAA
A
AAAA
A
AAAA
AAAAA
A
DSTi
C4
F0
9-138
D0
AAAA
A
AAAA
A
AAAA
A
AAAA
A
AAAA
AAAAA
A
D0 D1 D2 D3 D4 D5 D6 D7 C0 C1 C2 C3 C4 C5 C6 C7 B7 B6 B5 B4 B3 B2 B1 B0
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
AAAA
A
AAAA
AAAAA
A
AAAA
AAAAA
AAAAA
A
AAAA
AAAAA
AAAAA
A
AAAAA
AAAA
AAAAA
AAAAA
A
AAAA
AAAAA
A
AAAA
A
AAAA
AAAAA
A
AAAA
AAAAA
A
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
AAAA
A
AAAA
AAAAA
A
AAAA
AAAAA
AAAAA
A
AAAA
AAAAA
AAAAA
A
AAAAA
AAAA
AAAAA
AAAAA
A
AAAA
AAAAA
A
AAAA
A
AAAA
A
AAAA
AAAAA
A
AAAA
AAAAA
A
D0 D1 D2 D3 D4 D5 D6 D7 C0 C1 C2 C3 C4 C5 C6 C7 B7 B6 B5 B4 B3 B2 B1 B0
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
AAAAA
AAAA
AAAAA
A
AAAAA
AAAA
AAAAA
A
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
A
AAAA
AAAAA
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
AAAA
AAAAA
A
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
AAAA
AAAAA
A
AAAAA
AAAA
AAAAA
A
AAAAA
AAAAA
AAAA
A
AAAA
AAAAA
A
AAAAA
A
AAAA
DSTo
D0
Advance Information
MT9171/72
Advance Information
In DIGITAL NETWORK (DN) mode, upon entering
the DNIC from the DV and CD ports, the B-channel
data, D-channel D0 (and D1 for 160 kbit/s), the HK
bit of the C-channel (160kbit/s only) and a SYNC bit
are combined in a serial format to be sent out on the
line by the Transmit Interface (Figures 11, 12). The
SYNC bit produces an alternating 1-0 pattern each
frame in order for the remote end to extract the frame
alignment from the line. It is possible for the remote
end to lock on to a data bit pattern which simulates
this alternating 1-0 pattern that is not the true SYNC.
To decrease the probability of this happening the
DNIC may be programmed to put the data through a
prescrambler that scrambles the data according to a
predetermined polynomial with respect to the SYNC
bit. This greatly decreases the probability that the
SYNC pattern can be reproduced by any data on the
line. In order for the echo canceller to function
correctly, a dedicated scrambler is used with a
scrambling algorithm which is different for the SLV
and MAS modes. These algorithms are calculated in
such a way as to provide orthogonality between the
near and far end data streams such that the
correlation between the two signals is very low.
For any two DNICs on a link, one must be in SLV
mode with the other in MAS mode. The scrambled
data is differentially encoded which serves to make
the data on the line polarity-independent. It is then
biphase encoded as shown in Figure 10. See “Line
Interface” section for more details on the encoding.
Before leaving the DNIC the differentially encoded
biphase data is passed through a pulse-shaping
bandpass transmit filter that filters out the high and
low frequency components and conditions the signal
for transmission on the line.
The composite transmit and receive signal is
received at LIN. On entering the DNIC this signal
passes through a Precanceller which is a summing
amplifier and lowpass filter that partially cancels the
near-end signal and provides first order antialiasing
for the received signal. Internal, partial cancellation
F0
C4
AAAA
AAAAAA
A
AAA
AAAA
AAAAAAAAAAA
AAAA
AAAAAAAAAA
AAAA
AAAAA
AAAA
AAAAAAAAAAAAA
AAAA
AAAA
A
AA
AAAAAAAAAA
AAAA
AAAA
AAAA
AAAA
AA
A
AAAAAA
A
A
AAAAAAAA
AAAAAAA
AAA
AAAA
AAAAAAAA
AAAAAA
AA
A
AAAAAAAA
AAAAAAAA
AAAA
AAAA
A
AA
AAAA
AAAA
AAAA
AAAA
AA
A
AAA
AAAA
AAAAA
AAAA
AAAA
A
AA
AAAA
AAAA
AAAA
AAAA
AA
A
CDSTo AAAAA
AAAAAA
A
A C0 C1 C2 C3 C 4 C5 C6 C7 AAAA
AAAAAAAA
AAAAAAA
AAA
AAAAAAAA
AAAAAAAA
AAAAAA
AAD0 D1 D2 D3 D4 D5 D6 D7 AAAA
A
AAAAAAAA
AAAAAAAA
AAAA
AAAA
A
AA
AAAA
AAAA
AAAA
AAAA
AA
A C0
AAAA
A
A
AA
AAAA
AAAA
AAA
AAAA
AAAA
AAAA
AA
AAAA
A
AAAA
AAAA
AAAA
AAAA
A
AA
AAAA
AAAA
AAAA
AAAA
AA
A
AAAAAA
A
AAAAA
A
AAAAAAAAAAA
AAAAAAAAAAAAAA
A
AAAA
AAAAAAAAAAAA
AAAA
A
AA
AAAA
AAAA
AAAA
AAAA
AA
A
A
AA
AAAA
AAAA
AA
AA
AAAA
AAAA
AA
A
AAAA
AAA
AAAA
AAA
AAAA
AAAA
AAAA
AAA
AAAA
AAAA
AAAAAAAA
AAAA
A
AAAA
AAAA
AAAA
AAAA
AAAA
A
AAA
AAAAAAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAA
AA
AAAAA
AAAA
AAAA
AA
A
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AA
A
A
AAAAAAA
AAA
AAAA
AAAA
AAAA
AAD D D D D D D D AAAA
A
AAAAAAAA
AAAAAAAA
AAAA
AA
AAAA
AAAA
AA
AC
AAAA
AAA
AAAA
A
AAAA
AAAA
C0 C1 C2 C3 C 4 C5 C6 C7 AAAA
A
A
AAAA
AAAA
AAA
AAAA
AAAA
AAAA
AA
A
AAAA
AAAA
AAAA
AAAA
AAAA
A
AA
AAAA
AAAA
AAAA
AAAA
AA
A
CDSTi AAAA
0
1
2
3
4
5
6
7
A
AA
AAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA
AA
AAAA
AAAA
AA
A 0
AAAA
A
AAAA
AAAA
A
AAAA
AAAA
AAAA
A
AA
A
AAAA
AAAA
AAA
AAAA
AAAA
AAAA
AA
A
AAAA
AAAA
AAAA
AAAA
AAAA
A
AA
AAAA
AAAA
AAAA
AAAA
AA
A
AAAAAAA
A
AAAAAAAAAAA
AAAAAAAAAAAAAA
A
AAAA
AAAAAAAAAAAA
AA AAAAAAAA
AA
A
F0o
3.9 µsec
62.5 µsec
125 µsec
Channel Time 0
Channel Time 16
Figure 7 - CD Port (Modes 2,6)
CLD
TCK
CDi
C6
C7
C0
C1
C2
C3
C4
C5
C6
C7
C0
C1
CDo
C6
C7
C0
C1
C2
C3
C4
C5
C6
C7
C0
C1
Figure 8 - CD Port (Modes 1,5)
9-139
MT9171/72
Advance Information
the first DNIC in the chain receives the system F0
with the following devices receiving its predecessor’s
F0o.
of the near end signal may be disabled by holding
the Precan pin high. This mode simplifies the design
of external line transceivers used for loop extension
applications. The Precan pin features an internal
pull-down which allows this pin to be left
unconnected in applications where this function is
not required. The resultant signal passes through
a receive filter to bandlimit and equalize it. At this
point, the echo estimate from the echo canceller is
subtracted from the precancelled received signal.
This difference signal is then input to the echo
canceller as an error signal and also squared up by a
comparator and passed to the biphase receiver.
Within the echo canceller, the sign of this error signal
is determined. Depending on the sign, the echo
estimate is either incremented or decremented and
this new estimate is stored back in RAM.
In MOD mode, all the ports have a different format.
The line port again operates at 80 or 160 kbit/s,
however, there is no synchronization overhead, only
transparent data. The DV and CD ports carry serial
data at 80 or 160 kbit/s with the DV port transferring
all the data for the line and the CD port carrying the
C-channel only. In this mode the transfer of data at
both ports is synchronized to the TCK and RCK
clocks for transmit and receive data, respectively.
The CLD signal goes low to indicate the start of the
C-channel data on the CD port. It is used to load and
latch the input and output C-channel but has no
relationship to the data on the DV port.
The timebase in both SLV and MAS modes
(generated internally in SLV mode and externally in
MAS mode) is phase-locked to the received data
stream.
This phase-locked clock operates the
Biphase Decoder, Descrambler and Deprescrambler
in MAS mode and the entire chip in SLV mode. The
Biphase Decoder decodes the received encoded bit
stream resulting in the original NRZ data which is
passed onto the Descrambler and Deprescrambler
where the data is restored to its original content by
performing the reverse polynomials. The SYNC bits
are extracted and the Receive Interface separates
the channels and outputs them to the proper ports in
the proper channel times. The destination of the
various channels is the same as that received on the
input DV and CD ports.
Operating Modes (MS0-2)
The logic levels present on the mode select pins
MS0, MS1 and MS2 program the DNIC for different
operating modes and configure the DV and CD ports
accordingly.
Table 1 shows the modes
corresponding to the state of MS0-2. These pins
select the DNIC to operate as a MASTER or SLAVE,
in DUAL or SINGLE port operation, in MODEM or
DIGITAL NETWORK mode and the order of the C
and D channels on the CD port. Table 2 provides a
description of each mode and Table 3 gives a pin
configuration according to the mode selected for all
pins that have variable functions. These functions
vary depending on whether it is in MAS or SLV, and
whether DN or MOD mode is used.
The Transmit/Receive Timing and Control block
generates all the clocks for the transmit and receive
functions and controls the entire chip according to
the control register. In order that more than one
DNIC may be connected to the same DV and
CD ports an F0o signal is generated which signals
the next device in a daisy chain that its channel
times are now active.
In this arrangement only
Mode Select Pins
Mode
The overall mode of operation of the DNIC can be
programmed to be either a baseband modem
(MOD mode) or a digital network transceiver (DN
mode). As a baseband modem, transmit/receive
data is passed transparently through the device at 80
Operating Mode
MS2
MS1
MS0
SLV
0
0
0
0
0
1
1
E
E
0
1
0
2
E
E
E
0
1
1
3
E
E
E
E
E
1
0
0
4
E
E
E
1
0
1
5
E
E
1
1
0
6
E
E
E
1
1
1
7
E
E
0
MAS
DUAL
E
SINGL
MOD
E
E
Table 1. Mode Select Pins
E=Enabled
X=Not Applicable
Blanks are disabled
9-140
D-C
E
E
E
E
E
DN
X
E
X
E
C-D
ODE
E
X
E
E
E
X
E
E
E
MT9171/72
Advance Information
or 160 kbit/s by the DV port. The CD port transfers
the C-channel and D-Channel also at 80 or 160
kbit/s.
In DN mode, both the DV and CD ports operate as
ST-BUS streams at 2.048 Mbit/s. The DV port
transfers data over pins DSTi and DSTo while on the
CD port, the CDSTi and CDSTo pins are used. The
SINGL port option only exists in DN mode.
In MOD mode, DUAL port operation must be used
and the D, B1 and B2 channel designations no
longer exist. The selection of SLV or MAS will
determine which of the DNICs is using the externally
Mode
supplied clock and which is phase locking to the data
on the line. Due to jitter and end to end delay, one
end must be the master to generate all the timing for
the link and the other must extract the timing from
the receive data and synchronize itself to this timing
in order to recover the synchronous data. DUAL port
mode allows the user to use two separate serial
busses: the DV port for PCM/data (B channels) and
the CD port for control and signalling information (C
and D channels). In the SINGL port mode, all four
channels are concatenated into one serial stream
and input to the DNIC via the DV port. The order of
the C and D channels may be changed only in DN/
DUAL mode. The DNIC may be configured to
Function
SLV
SLAVE - The chip timebase is extracted from the received line data and the external 10.24 MHz
crystal is phase locked to it to provide clocks for the entire device and are output for the external
system to synchronize to.
MAS
MASTER - The timebase is derived from the externally supplied data clocks and 10.24 MHz clock
which must be frequency locked. The transmit data is synchronized to the system timing with the
receive data recovered by a clock extracted from the receive data and resynchronized to the system
timing.
DUAL
DUAL PORT - Both the CD and DV ports are active with the CD port transferring the C&D channels
and the DV port transferring the B1& B2 channels.
SINGL
SINGLE PORT - The B1& B2, C and D channels are all transferred through the DV port. The CD
port is disabled and CDSTi should be pulled high.
MOD
MODEM - Baseband operation at 80 or 160 kbits/s. The line data is received and transmitted
through the DV port at the baud rate selected. The C-channel is transferred through the CD port
also at the baud rate and is synchronized to the CLD output.
DN
D-C
C-D
ODE
DIGITAL NETWORK - Intended for use in the digital network with the DV and CD ports operating at
2.048 Mbits/s and the line at 80 or 160 kbits/s configured according to the applicable ISDN
recommendation.
- The D-channel is transferred before the C-channel following F0.
C BEFORE D-CHANNEL - The C-channel is transferred before the D-channel following F0.
OUTPUT DATA ENABLE - When mode 7 is selected, the DV and CD ports are put in high
D BEFORE C-CHANNEL
impedance state. This is intended for power-up reset to avoid bus contention and possible damage
to the device during the initial random state in a daisy chain configuration of DNICs. In all the other
modes of operation DV and CD ports are enabled during the appropriate channel times.
Table 2. Mode Definitions
F0/CLD
F0o/RCK
C4/TCK
Mode
#
Name
Input/Output
Name
Input/Output
Name
Input/Output
0
1
F0
CLD
Input
Output
F0o
RCK
Output
Output
C4
TCK
Input
Output
2
F0
Input
F0o
Output
C4
Input
3
F0
Input
F0o
Output
C4
Input
4
F0
Output
F0o
Output
C4
Output
5
CLD
Output
RCK
Output
TCK
Output
6
F0
Output
F0o
Output
C4
Output
7
F0
Input
F0o
Output
Table 3. Pin Configurations
C4
Input
9-141
MT9171/72
Advance Information
While in the MOD mode only DUAL port operation
can be used.
transfer the D-channel in channel 0 and the Cchannel in channel 16 or vice versa. One other
feature exists; ODE, where both the DV and CD
ports are tristated in order that no devices are
damaged due to excessive loading while all DNICs
are in a random state on power up in a daisy chain
arrangement.
In order for more than one DNIC to be connected to
any one DV and CD port, making more efficient use
of the busses, the DSTo and CDSTo outputs are put
into high impedance during the inactive channel
times of the DNIC. This allows additional DNICs to
be cascaded onto the same DV and CD ports. When
used in this way a signal called F0o is used as an
indication to the next DNIC in a daisy chain that its
channel time is now active. Only the first DNIC in the
chain receives the system frame pulse and all
others receive the F0o from its predecessor in
the chain.
This allows up to 16 DNICs to be
cascaded.
DV Port (DSTi/Di, DSTo/Do)
The DV port transfers data or PCM encoded voice to
and from the line according to the particular mode
selected by the mode select pins. The modes
affecting the configuration of the DV port are MOD or
DN and DUAL or SINGL. In DN mode the DV port
operates as an ST-BUS at 2.048 Mbit/s with 32, 8 bit
channels per frame as shown in Figure 9. In this
mode the DV port channel configuration depends
upon whether DUAL or SINGL port is selected.
When DUAL port mode is used, the C and D
channels are passed through the CD port and the B1
and B2 channels are passed through the DV port. At
80 kbit/s only one channel of the available 32 at the
DV port is utilized, this being channel 0 which carries
the B1-channel. This is shown in Figure 3. At 160
kbit/s, two channels are used, these being 0 and 16
carrying the B1 and B2 channels, respectively. This
is shown in Figure 4. When SINGL port mode is
used, channels B1, B2, C and D are all passed via
the DV port and the CD port is disabled. See CD port
description for an explanation of the C and D
channels.
CD Port (CDSTi/CDi, CDSTo/CDo)
The CD port is a serial bidirectional port used only in
DUAL port mode. It is a means by which the DNIC
receives its control information for things such as
setting the bit rate, enabling internal loopback tests,
sending status information back to the system and
transferring low speed signalling data to and from
the line.
The CD port is composed of the C and D-Channels.
The C-channel is used for transferring control and
status information between the DNIC and the
system. The D-channel is used for sending and
receiving signalling information and lower speed
data between the line and the system. In DN/DUAL
mode the DNIC receives a C-channel on CDSTi
while transmitting a C-channel on CDSTo. Fifteen
channel times later (halfway through the frame) a Dchannel is received on CDSTi while a D-channel is
transmitted on CDSTo. This is shown in Figure 7.
The order of the C and D bytes in DUAL port mode
can be reversed by the mode select pins. See Table
1 for a listing of the byte orientations.
The D-channel is always passed during channel time
0 followed by the C and B1 channels in channel
times 1 and 2, respectively for 80 kbit/s. See Figure
5. For 160 kbit/s the B2 channel is added and
occupies channel time 3 of the DV port. See Figure
6. For all of the various configurations the bit orders
are shown by the respective diagram. In MOD mode
the DV and CD ports no longer operate at 2.048
Mbits/s but are continuous serial bit streams
operating at the bit rate selected of 80 or 160 kbit/s.
The D-channel exists only in DN mode and may be
used for transferring low speed data or signalling
F0
125 µsec
ST-BUS
Channel
31
Channel
0
Channel
1
Channel
2
Most
Significant
Bit (First)
Bit 7
Channel
29
••••••••
Bit 6
Bit 5
Bit 4
Bit 3
3.9 µsec
Figure 9 - ST-BUS Format
9-142
Channel
30
Bit 2
Bit 1
Channel
31
Bit 0
Channel
0
Least
Significant
Bit (Last)
MT9171/72
Advance Information
information over the line at 8, 16 or 64 kbit/s (by
using the DINB feature). The information passes
transparently through the DNIC and is transmitted to
or received from the line at the bit rate selected in
the Control Register.
If the bit rate is 80 kbit/s, only D0 is transmitted and
received. At 160 kbit/s, D0 and D1 are transmitted
and received. When the DINB bit is set in the Control
Register the entire D-channel is transmitted and
received in the B1-channel timeslot.
The C-channel is used for transferring control and
status information between the DNIC and the
system. The Control and Diagnostics Registers are
accessed through the C-channel. They contain
information to control the DNIC and carry out the
diagnostics as well as the HK bit to be transmitted on
the line as described in Tables 4 and 5. Bits 0 and 1
of the C-channel select between the Control and
Diagnostics Register. If these bits are 0, 0 then the
C-channel information is written to the Control
Register (Table 4). If they are 0, 1 the C- channel is
written to the Diagnostics Register (Table 5).
The Diagnostics Register Reset bit (bit 2) of the
Control Register determines the reset state of the
Diagnostics Register. If, on writing to the Control
Register, this bit is set to logic “0”, the Diagnostics
Register will be reset coincident with the frame
pulse. When this bit is logic “1”, the Diagnostics
Register will not be reset.
In order to use the
diagnostic features, the Diagnostics Register must
be continuously written to. The output C-channel
sends status information from the Status Register to
the system along with the received HK bit as shown
in Table 6.
In MOD mode, the CD port is no longer an ST-BUS
but is a serial bit stream operating at the bit rate
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Reg Sel-1
Reg Sel-2
DRR
BRS
DINB
PSEN
ATTACK
TxHK
Default Mode Selection (Refer to Table 4a)
Bit
Name
Description
0
Reg Sel-1
Register Select-1. Must be set to ’0’ to select the Control Register.
1
Reg Sel-2
Register Select-2. Must be set to ’0’ to select the Control Register.
2
DRR
Diagnostics Register Reset. Writing a "0" to this bit will cause a diagnostics register reset
to occur coincident with the next frame pulse as in the MT8972A. When this bit is a logic
"1", the Diagnostics Register will not be reset.
3
BRS
Bit Rate Select. When set to ’0’ selects 80 kbit/s. When set to ’1’, selects 160 kbit/s.
4
DINB
➁
D-Channel in B Timeslot. When ’0’, the D-channel bits (D0 or D0 and D1) corresponding
to the selected bit rate (80 or 160 kbit/s) are transmitted during the normal D-channel bit
times. When set to ’1’, the entire D-channel (D0-D7) is transmitted during the B1-channel
timeslot on the line providing a 64 kbit/s D-channel link.
5
PSEN➁
Prescrambler/Deprescrambler Enable. When set to ’1’, the data prescrambler and
deprescrambler are enabled. When set to ’0’, the data prescrambler and deprescrambler
are disabled.
6
ATTACK➁
Convergence Speedup. When set to ’1’, the echo canceller will converge to the reflection
coefficient much faster. Used on power-up for fast convergence.➀ When ’0’, the echo
canceller will require the normal amount of time to converge to a reflection coefficient.
7
TxHK➁
Transmit Housekeeping. When set to ’0’, logic zero is transmitted over the line as
Housekeeping Bit. When set to ’1’, logic one is transmitted over the line as
Housekeeping Bit.
Table 4. Control Register
Notes:
➀ Suggested use of ATTACK:
-At 160 kbit/s full convergence requires 850 ms with ATTACK held high for the first 240 frames or 30 ms.
-At 80 kbit/s full convergence requires 1.75 s with ATTACK held high for the first 480 frames or 60 ms.
➁ When bits 4-7 of the Control Register are all set to one, the DNIC operates in one of the default modes as defined in Table 4a,
depending upon the status of bit-3.
9-143
MT9171/72
Advance Information
C-Channel
(Bit 0-7)
Internal Control
Register
Internal Diagnostic
Register
XXX01111
00000000
01000000
XXX11111
00010000
Description
Default Mode-1➂: Bit rate is 80 kbit/s. ATTACK,
PSEN, DINB, DRR and all diagnostics are disabled.
TxHK=0.
Default Mode-2➃ Bit rate is 160 kbit/s. ATTACK,
PSEN, DINB, DRR and all diagnostics are disabled.
TxHK=0.
Table 4a. Default Mode Selection
01000000
Notes:
➂ Default Mode 1 can also be selected by tying CDSTi/CDi pin low when DNIC is operating in dual mode.
➃ Default Mode 2 can also be selected by tying CDSTi/CDi pin high when DNIC is operating in dual mode.
bit 0
bit 1
Reg Sel-1
Reg Sel-2
bit 2
bit 3
Loopback
bit 4
bit 5
bit 6
bit 7
FUN
PSWAP
DLO
Not Used
Default Mode Selection
(Refer to Table 4a)
Bit
Name
Description
0
Reg Sel-1
Register Select-1. Must be set to ’0’ to select the Diagnostic Register.
1
Reg Sel-2
Register Select-2. Must be set to ’1’ to select the Diagnostic Register.
2,3
Loopback
Bit 2
0
0
1
1
Bit 3
0
1
0
1
All loopback testing functions disabled. Normal operation.
DSTi internally looped back into DSTo for system diagnostics.
LOUT is internally looped back into LIN for system diagnostics.➁
DSTo is internally looped back into DSTi for end-to-end testing.➂
4
FUN➀
5
PSWAP➀
Polynomial Swap. When set to ’1’, the scrambling and descrambling polynomials
are interchanged (use for MAS mode only). When set to ’0’, the polynomials retain
their normal designations.
6
DLO➀
Disable Line Out. When set to ’1’, the signal on LOUT is set set to VBias. When set to
’0’, LOUT pin functions normally.
7
Not Used
Force Unsync. When set to ’1’, the DNIC is forced out-of-sync to test the SYNC
recovery circuitry. When set to ’0’, the operation continues in synchronization.
Must be set to ’0’ for normal operation.
Table 5. Diagnostic Register
Notes:
➀ When bits 4-7 of the Diagnostic Register are all set to one, the DNIC operates in one of the default modes as defined in Table 4a,
depending upon the status of bit-3.
➁ Do not use L OUT to L IN loopback in DN/SLV mode.
➂ Do not use DSTo to DSTi loopback in MOD/MAS mode.
selected. It continues to transfer the C-channel but
the D-channel and the HK bit no longer exist. DUAL
port operation must be used in MOD mode. The Cchannel is clocked in and out of the CD port by TCK
and CLD with TCK defining the bits and CLD the
channel boundaries of the data stream as shown in
Figure 8.
9-144
Line Port (L IN, L OUT )
The line interface is made up of L OUT and L IN with
LOUT driving the transmit signal onto the line and L IN
receiving the composite transmit and receive signal
from the line. The line code used in the DNIC is
Biphase and is shown in Figure 10. The scrambled
NRZ data is differentially encoded meaning the
previous differential encoded output is XOR’d with
the current data bit which produces the current
output. This is then biphase encoded where
MT9171/72
Advance Information
0
1
SYNC
2
CHQual
3
Rx HK
4
5
6
Future Functionality
7
ID
Status
Register
Name
0
SYNC
Synchronization - When set this bit indicates that synchronization to the received
line data sync pattern has been acquired. For DN mode only.
1-2
CHQual
Channel Quality - These bits provide an estimate of the receiver’s margin against
noise. The farther this 2 bit value is from 0 the better the SNR.
3
Rx HK
Housekeeping - This bit is the received housekeeping (HK) bit from the far end.
4-6
Future
Future Functionality. These bits return Logic 1 when read.
7
ID
Function
This bit provides a hardware identifier for the DNIC revision. The MT9171/72 will
return a logic “0” for this bit. (Logic “1” returned for MT8972A.)
Table 6. Status Register
transitions occur midway through the bit cell with a
negative going transition indicating a logic "0" and a
positive going transition indicating a logic "1".
There are some major reasons for using a biphase
line code. The power density is concentrated in a
spectral region that minimizes dispersion and
differential attenuation. This can shorten the line
response and reduce the intersymbol interference
which are critical for adaptive echo cancellation.
There are regular zero crossings halfway through
every bit cell or baud which allows simple clock
extraction at the receiving end. There is no D.C.
content in the code so that phantom power feed may
be applied to the line and simple transformer
coupling may be used with no effect on the data. It is
bipolar, making data reception simple and providing
a high signal to noise ratio. The signal is then passed
through a bandpass filter which conditions the signal
for the line by limiting the spectral content from
0.2f Baud to 1.6f Baud and on to a line driver where it is
made available to be put onto the line biased at
VBias. The resulting transmit signal will have a
distributed spectrum with a peak at 3/4fBaud. The
transmit signal (L OUT) may be disabled by holding the
LOUT DIS pin high or by writing DLO (bit 6) of the
Diagnostics Register to logic “1”. When disabled,
LOUT is forced to the VBias level. LOUT DIS has an
internal pull-down to allow this pin to be left not
connected in applications where this function is not
required. The receive signal is the above transmit
signal superimposed on the signal from the remote
end and any reflections or delayed symbols of the
near end signal.
The frame format of the transmit data on the line is
shown in Figures 11 and 12 for the DN mode at 80
and 160 kbit/s. At 80 kbit/s a SYNC bit for frame
recovery, one bit of the D-channel and the B1channel are transmitted. At 160 kbit/s a SYNC bit,
the HK bit, two bits of the D-channel and both B1 and
B2 channels are transmitted.
If the DINB bit of the Control Register is set, the
entire D-channel is transmitted during the B1channel timeslot. In MOD mode the SYNC, HK and
D-channel bits are not transmitted or received but
rather a continuous data stream at 80 or 160 kbit/s is
present. No frame recovery information is present on
the line in MOD mode.
9-145
MT9171/72
Bits
Data
NRZ Data
Differential
Encoded
Differential
Encoded
Biphase
Transmit
Line Signal
Note:
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
Advance Information
Bit 7
Bit 6
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
1
Bit 5
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
1
1
Bit 4
AA
A
AA
A
AA
A
A
A
AA
A
AA
A
AA
A
A
AA
A
A
AA
A
AA
A
A
AA
A
A
AA
A
AA
A
AA
A
A
AA
A
AA
AA
AA
A
AA
AA
AA
AA
0
Bit 3
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
0
A
AA
A
AA
A
AA
A
A
A
AA
A
AA
A
AA
A
A
AA
A
A
AA
A
AA
A
A
AA
A
A
AA
A
AA
A
AA
A
A
AA
A
AA
AA
AA
A
AA
AA
AA
AA
Bit 2
1
Bit 1
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
0
Bit 0
AAA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
0
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AAVBias
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
Last bit sent was a logic 0
Figure 10 - Data & Line Encoding
F0
LOUT
B17
SYNC
D0
B10
B11
B12
B13
B14
B15
B16
B17
SYNC
Figure 11 - Frame Format - 80 kbit/s (Modes 0, 2, 3, 4, 6)
F0
LOUT
SYNC HK0
D1
D0
B10 B11 B12 B13 B14 B15 B16 B17 B20 B21 B22 B23 B24 B25 B26 B27 SYNC
Figure 12 - Frame Format - 160 kbit/s (Modes 0, 2, 3, 4, 6)
9-146
MT9171/72
Advance Information
Applications
If the scramblers power up with all zeros in them,
they are not capable of randomizing all-zeros data
sequence. This increases the correlation between
the transmit and receive data which may cause loss
of convergence in the echo canceller and high bit
error rates.
Typical connection diagrams are shown in Figures
13 and 14 for the DN mode as a MASTER and
SLAVE, respectively. LOUT is connected to the
coupling transformer through a resistor R2 and
capacitors C2 and C2’ to match the line
characteristic impedance. Suggested values of R2,
C2 and C2’ for 80 and 160 kbit/s operation are
provided in Figures 13 and 14. Overvoltage
protection is provided by R1, D1 and D2. C1 is
present to properly bias the received line signal for
the LIN input. A 2:1 coupling transformer is used to
couple to the line with a secondary center tap for
optional phantom power feed. Varistors have been
shown for surge protection against such things as
lightning strikes.
In DN mode the insertion of the SYNC pattern will
provide enough pseudo-random activity to maintain
convergence. In MOD mode the SYNC pattern is not
inserted. For this reason, at least on ”1” must be fed
into the DNIC on power up to ensure that the
scramblers will randomize any subsequent all-zeros
sequence.
C2’ = 1.5 nF
DV Port ST-BUS
CD Port ST-BUS
Master Clocks
{
DSTi
{
CDSTi
CDSTo
{
F0
C4
D1 = D2 = MUR405
LOUT
R2 = 390Ω
D2
2:1
Line Feed
Voltage
R1 = 47Ω
LIN
1.0 µF
MS0
Mode Select
Lines
+5V
C2 = 22 nF
DSTo
For 80 kbit/s: C2’ = 3.3 nF
+5V
MT9171/72
0.33 µF
0.33 µF
OSC1
MS1
MS2
OSC2
F0o
VRef
VBias
D.C. coupled,
Frequency locked
10.24 MHz clock.
NC Refer to AC Electrical
Characteristics
Clock Timing
C1 = 0.33 µF
DN Mode.
68 Volts
(Typ)
2.5 Joules
0.02 Watt
Note: Low leakage diodes (1 & 2) are required so
that the DC voltage at LIN ≈ VBias
To Next DNIC
Figure 13 - Typical Connection Diagram - MAS/DN Mode, 160 kbit/s
C2’ = 1.5 nF
DV Port ST-BUS
{
CD Port ST-BUS
{
CDSTi
CDSTo
Master Clocks
{
F0
C4
Mode Select
Lines
+5V
0.33 µF
0.33 µF
C2 = 22 nF
DSTi
DSTo
D1 = D2 = MUR405
LOUT
R2 = 390Ω
D2
2:1
R1 = 47Ω
LIN
1.0 µF
MS0
MS1
MS2
OSC1
VRef
OSC2
VBias
For 80 kbit/s: C2’ = 3.3 nF
+5V
MT9171/72
Supply
68 Volts
(Typ)
2.5 Joules
0.02 Watt
10.24 MHz XTAL
C3=33pF=C4
C1 = 0.33 µF
Note: Low leakage diodes (1 & 2) are required so
that the DC voltage at LIN ≈ VBias
Figure 14 - Typical Connection Diagram - SLV/DN Mode, 160 kbit/s
9-147
MT9171/72
Advance Information
Absolute Maximum Ratings**
- Voltages are with respect to ground (VSS) unless otherwise stated.
Parameter
Symbol
Min
Max
Units
1
Supply Voltage
VDD
-0.3
7
V
2
Voltage on any pin (other than supply)
VMax
-0.3
VDD+0.3
V
3
Current on any pin (other than supply)
IMax
40
mA
4
Storage Temperature
TST
+150
°C
5
Package Power Dissipation (Derate 16mW/°C above 75°C)
PDiss
750
mW
-65
** Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Recommended Operating Conditions† - Voltages are with respect to ground (VSS ) unless otherwise stated.
Characteristics
Sym
Min
Typ*
Max
Units
Test Conditions
1
Operating Supply Voltage
VDD
4.75
5.00
5.25
V
2
Operating Temperature
TOP
-40
+85
°C
3
Input High Voltage (except OSC1)
VIH
2.4
VDD
V
for 400 mV noise margin
4
Input Low Voltage (except OSC1)
VIL
0
0.4
V
for 400 mV noise margin
* Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
† Parameters over recommended temperature & power supply voltage ranges.
DC Electrical Characteristics†
- Voltages are with respect to ground (VSS) unless otherwise stated.
Characteristics
Sym
Min
Typ*
Max
Units
Test Conditions
1
Operating Supply Current
IDD
2
Output High Voltage (ex OSC2)
VOH
2.4
V
3
Output High Current
(except OSC2)
IOH
10
mA
Source current. VOH=2.4V
Output High Current - OSC2
IOH
10
µA
Source current VOH=3.5V
Output Low Voltage (ex OSC2)
VOL
V
IOL=5mA
Output Low Current
(except OSC2)
IOL
5
Output Low Current - OSC2
IOL
10
8
High Imped. Output Leakage
IOZ
9
Output Voltage
VO
4
5
6
7
O
U
T
P
U
T
S
10
(VRef)
(VBias)
10
mA
0.4
7.5
10
VBias-1.8
mA
Sink current. VOL=0.4V
µA
Sink current. VOL=1.5V
µA
VIN=VSS to VDD
V
V
VDD/2
11
Input High Voltage (ex OSC1)
VIH
12
Input Low Voltage (ex OSC1)
VIL
Input High Voltage (OSC1)
VIHo
Input Low Voltage (OSC1)
VILo
1.0
V
IIL
10
µA
13
14
15
16
17
I
N
P
U
T
S
Input Leakage Current
IOH=10mA
2.0
V
0.8
4.0
V
V
Input Pulldown Impedance
LOUT DIS and Precan
ZPD
30
kΩ
Input Leakage Current for
OSC1 Input
IIOSC
20
µA
VIN=VSS to VDD
* Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
† Parameters over recommended temperature & power supply voltage ranges.
9-148
MT9171/72
Advance Information
AC Electrical Characteristics†
- Voltages are with respect to ground (VSS) unless otherwise stated.
Characteristics
Sym
Min
Typ*
Max
Units
5.0
Vpp
Test Conditions
1
Input Voltage
(LIN)
VIN
2
Input Current
(LIN)
IIN
-10
+10
µA
fBaud=160 kHz
Input Impedance
(LIN)
ZIN
20
40
kΩ
fBaud=160 kHz
3
4
5
6a
I
N
P
U
T
S
Crystal/Clock Frequency
fC
Crystal/Clock Tolerance
TC
-100
0
+100
ppm
DCC
40
50
60
%
Normal temp. & VDD
DCC
45
50
55
%
Recommended at max./
min. temp. & VDD
CL
33
50
pF
From OSC1 & OSC2 to VSS.
Co
8
pF
500
100
Ω
kΩ
Crystal/Clock Duty Cycle ➀
6b
Crystal/Clock Duty Cycle
7
Crystal/Clock Loading
8
9
10
11
O
U
T
P
U
T
S
Output Capacitance
➀
(LOUT)
Load Resistance
(LOUT)
(VBias, VRef)
RLout
Load Capacitance
(LOUT)
(VBias, VRef)
CLout
Output Voltage
10.24
MHz
20
pF
µF
Capacitance to VBias.
4.6
Vpp
RLout = 500Ω, CLout = 20pF
0.1
(LOUT)
Vo
3.2
4.3
† Timing is over recommended temperature & power supply voltages.
* Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
➀ Duty cycle is measured at V DD /2 volts.
.
AC Electrical Characteristics† - Clock Timing - DN Mode (Figures 16 & 17)
Characteristics
Sym
Min
Typ*
Max
Units
1
C4 Clock Period
tC4P
244
ns
2
C4 Clock Width High or Low
tC4W
122
ns
3
Frame Pulse Setup Time
tF0S
50
ns
4
Frame Pulse Hold Time
tF0H
50
ns
5
Frame Pulse Width
tF0W
6
10.24 MHz Clock Jitter (wrt C4)
JC
244
-15
Test Conditions
In Master Mode - Note 1
ns
+15
ns
Note 2
† Timing is over recommended temperature & power supply voltages.
* Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
Notes: 1)
When operating as a SLAVE the C4 clock has a 40% duty cycle.
2)
When operating in MAS/DN Mode, the C4 and Oscillator clocks must be externally frequency-locked (i.e.,
F C =2.5xfC4). The relative phase between these two clocks (Φ in Fig. 17) is not critical and may vary from
0 ns to tC4P . However, the relative jitter must be less than JC (see Figure 17).
F0b
C4
ST-BUS
BIT CELLS
Channel 31 Channel 0
Bit 0
Bit 7
Channel 0
Bit 6
Figure 15 - C4 Clock & Frame Pulse Alignment for ST-BUS Streams
9-149
MT9171/72
Advance Information
tC4W
tC4P
2.0V
C4
0.8V
tF0S
tF0H
tC4W
tF0W
F0
2.0V
0.8V
Figure 16 - C4 Clock & Frame Pulse Alignment for ST-BUS Streams in DN Mode
C4
2.0V
0.8V
Φ
JC
3.0V
OSC1
2.0V
Figure 17 - Frequency Locking for the C4 and OSC1 Clocks in MAS/DN Mode
AC Electrical Characteristics† - Clock Timing - MOD Mode (Figure 18)
80 kbit/s
Characteristics
160 kbit/s
Sym
Units
Min
Typ*
Max Min
Typ*
Max
1 TCK/RCK Clock Period
tCP
12.5
6.25
µs
2 TCK/RCK Clock Width
tCW
6.25
3.125
µs
3 TCK/RCK Clock Transition Time
tCT
20
20
ns
4 CLD to TCK Setup Time
tCLDS
3.125
1.56
µs
5 CLD to TCK Hold Time
tCLDH
3.125
1.56
µs
6 CLD Width Low
tCLDW
6.05
2.925
µs
7 CLD Period
tCLDP
8xtCP
8xtCP
µs
Test
Conditions
CL=40pF
† Timing is over recommended temperature & power supply voltage ranges.
* Typical figures are at 25°C, for design aid only: not guaranteed and not subject to production testing.
tCP
tCT
tCW
2.4V
RCK
0.4V
tCP
2.4V
TCK
0.4V
tCLDH
tCLDS
tCW
tCT
tCLDW
2.4V
CLD
0.4V
Note 1: TCK and CLD are generated on chip and provide the data clocks for the CD port and the transmit section of the
DV port. RCK, also generated on chip, is extracted from the receive data and only clocks out the data at the Do output
and may be skewed with respect to TCK due to end-to-end delay.
Note 2: At the slave end TCK is phase locked to RCK.
The rising edge of TCK will lead the rising edge of RCK by approximately 90o.
Figure 18 - RCK, TCK & CLD Timing For MOD Mode
9-150
MT9171/72
Advance Information
AC Electrical Characteristics† - Data Timing - DN Mode (Figure 19)
Characteristics
Sym
Min
Typ*
Max
Units
Test Conditions
1
DSTi/CDSTi Data Setup Time
tRS
30
-10
ns
2
DSTi/CDSTi Data Hold Time
tRH
50
10
ns
3a
DSTo/CDSTo Data Delay
tTD
60
120
ns
CL=40pF
3b
DSTo/CDSTo High Z to Data Delay
tZTD
60
140
ns
CL=40pF
† Timing is over recommended temperature & power supply voltage ranges.
* Typical figures are at 25°C, for design aid only: not guaranteed and not subject to production testing.
Bit
Stream
Bit Cell
2.0V
C4
DSTi
CDSTi
0.8V
2.0V
0.8V
tTD
tZTD
DSTo
CDSTo
tTD
tRH
tRS
2.4V
0.4V
Figure 19 - Data Timing For DN Mode
†
AC Electrical Characteristics - Data Timing - MOD Mode (Figure 20)
Characteristics
Sym
80 kbit/s
Min
160 kbit/s
Typ*
Max Min
Typ*
Max
Units
Test
Conditions
1
Di/CDi Data Setup Time
tDS
150
150
ns
2
Di/CDi Data Hold Time
tDH
4.5
2.5
µs
3
Do Data Delay Time
tRD
70
70
ns
CL=40pF
4
CDo Data Delay Time
tTD
70
70
ns
CL=40pF
† Timing is over recommended temperature & power supply voltage ranges.
* Typical figures are at 25°C, for design aid only: not guaranteed and not subject to production testing.
Performance Characteristics of the MT9171 DSIC
Characteristics
Sym
Min
Typ*
Max
Units
Test Conditions
0
30
25
dB
SNR≥16.5dB
(300kHz
bandlimited noise)
1
Allowable Attenuation for Bit Error
Rate of 10-6 (Note 1)
Afb
2
Line Length at 80 kbit/s
-24 AWG
-26 AWG
L80
3.0
2.2
km
attenuation - 6.9 dB/km
attenuation - 10.0 dB/km
3
Line Length at 160 kbit/s -24 AWG
-26 AWG
L160
3.0
2.2
km
attenuation - 8.0 dB/km
attenuation - 11.5 dB/km
Performance Characteristics of the MT9172 DNIC
Characteristics
Sym
Min
Typ*
Max
Units
Test Conditions
0
40
33
dB
SNR≥16.5dB
(300kHz
bandlimited noise)
1
Allowable Attenuation for Bit Error
Rate of 10-6 (Note 1)
Afb
2
Line Length at 80 kbit/s
-24 AWG
-26 AWG
L80
5.0
3.4
km
attenuation - 6.9 dB/km
attenuation - 10.0 dB/km
3
Line Length at 160 kbit/s -24 AWG
-26 AWG
L160
4.0
3.0
km
attenuation - 8.0 dB/km
attenuation - 11.5 dB/km
Note 1: Attenuation measured from Master L OUT to Slave LIN at 3/4baud frequency.
* Typical figures are at 25°C, for design aid only: not guaranteed and not subject to production testing.
9-151
MT9171/72
Advance Information
Figure 20 - Data Timing for Master Modem Mode
9-152
MT9171/72
Advance Information
TCK
2.4V
0.4V
tDS
tDH
¼ tCP
Di
CDI
2.0V
0.8V
tTD
CDo
tTD
2.4V
0.4V
RCK
2.4V
Do
0.4V
Figure 21 - Data Timing for Slave Modem Mode
9-153
MT9171/72
Notes:
9-154
Advance Information