NEC LD7111

DATA S H E E T
HIGH POWER KLYSTRON
FOR GROUND TERMINALS
LD7111 SERIES
17 GHz BAND, 1.7 kW, HIGH EFICIENCY, HIGH POWER GAIN
GENERAL DESCRIPTION
The series of NEC LD7111 is a five-cavity Klystron Amplifier
and ideal for use in the earth-to-satellite communication systems. These are designed for operating at 1.7 kW CW over the
frequency range of 17.3 to 18.4 GHz.
The instantaneous bandwidth of minus one-decibel is at least
90 MHz over the entire 1.1 GHz range.
All tubes are forced-air-cooled at any power level. An automatic channel tuner, which changes the operating frequency very
quickly and simply, is available in all the series.
Furthermore, they are of rugged and reliable design offering
long life service.
NEC LD7111 series is compatible with VKU7791Z6 by using
an additional adapter.
FEATURES
™ Compact and Light Weight (27 kg approx.)
™ High Efficiency
(The DC to RF conversion efficiency is typically 23 % or
higher.)
™ High Power Gain
™ Long Life and High Stability
™ Simple Cooling System (forced-air-cooled)
™ Automatic Channel Tuner (8-12 Channels)
Hand Tuner model is also available.
™ Permanent Magnet Focusing
™ Rugged Construction
For safe use of microwave tubes, refer to NEC document “Safety instructions to all personnel
handling electron tubes” (ET0048EJ∗V∗UM00)
The information in this document is subject to change without notice.
Document No. ET0404EJ2V0DS00 (2nd edition)
(GC-1069)
Date Published August 1998 M
Printed in Japan
©
1994
LD7111 SERIES
GENERAL CHARACTERISTICS
ELECTRICAL
Frequency ………………………………………………
17.3 to 18.4 GHz
Output Power …………………………………………
1.7 kW
Heater Voltage …………………………………………
6.5 V
Heater Current …………………………………………
3.2 A
Cathode Type …………………………………………
Indirectly Heated, Impregnated
Cathode Warm-up Time ……………………………
300 s
MECHANICAL
Dimensions ……………………………………………
See Outline
Weight …………………………………………………
27 kg approx.
Focusing ………………………………………………
Permanent Magnet
Mounting Position ……………………………………
Vertical (Cathode down)
Cooling …………………………………………………
Forced Air
Electrical Connections ………………………………
See Outline
RF Connections
Input …………………………………………………
Output ………………………………………………
Cavity Tuning Method ………………………………
Mates with UG-419/U Flange
Mates with UG-419/U Flange
8-12 Channel Preset Tuning
(Hand Tuner is also available)
ABSOLUTE RATINGS ( Note 1, 2 and 3 )
ELECTRICAL
Min.
Heater Voltage …………………………………………
Max.
Unit
4.5
7.8
V
–
7.0
A
Heater Current …………………………………………
–
4.5
A
Heater Warm-up Time ………………………………
300
–
s
Body Voltage …………………………………………
–
10.0
kV
Body Current …………………………………………
–
25.0
mA
Collector Voltage ………………………………………
–
10.0
kV
Collector Current ………………………………………
–
1.0
A
Heater Surge Current
………………………………
Cathode Current ………………………………………
–
1.0
A
DC Input Power ………………………………………
–
9.3
kW
Normal Value ………………………………………
–
1.2 : 1
Instantaneous Value ………………………………
–
1.5 : 1
–
+250
Cooling Air Temperature ……………………………
–10
+50
°C
Collector Air Flow ……………………………………
515
–
kg/hr
Load VSWR
MECHANICAL
Collector Temperature ………………………………
°C
Body Air Flow …………………………………………
83
–
kg/hr
Gun Air Flow …………………………………………
41
–
kg/hr
Operating ……………………………………………
+5
+50
°C
Storage ………………………………………………
–50
+70
°C
ENVIRONMENTAL
Ambient Temperature
2
LD7111 SERIES
TYPICAL OPERATION (Note 3, 4 and 5)
Unit
Frequency …………………………………………………
17.7
GHz
Heater Voltage (Note 4) …………………………………
6.5
V
Heater Current ……………………………………………
3.2
A
Body Voltage ………………………………………………
9.4
kV
Body Current ………………………………………………
3.0
mA
Collector Voltage …………………………………………
9.4
kV
Collector Current …………………………………………
0.85
A
Cathode Current …………………………………………
0.85
A
DC Input Power
…………………………………………
8.0
kW
Driving Power ……………………………………………
100
mW
Output Power ……………………………………………
1.8
kW
Power Gain ………………………………………………
42
dB
Band Width (-1 dB) ………………………………………
90
MHz
Collector Air Flow ………………………………………
530
kg/hr
Collector Air Pressure Drop ……………………………
2,000
Pa
Body Air Flow ……………………………………………
85
kg/hr
Body Air Pressure Drop …………………………………
34
Pa
Gun Air Flow ………………………………………………
43
kg/hr
Note 1 : Absolute rating should not be exceeded under continuous or transient conditions. A single absolute
rating may be the limitation and simultaneous operation at more than one absolute rating may not be
possible. Equipment design should limit voltage and environmental variations so that ratings will be
exceeded.
Note 2 : The Klystron body should be at ground potential in operation.
Note 3 : All voltages are referred to the cathode potential except the heater voltage.
Note 4 : The optimum operating value is shown on a test performance sheet for each tube.
Note 5 : Characteristics and operating values on this Data Sheet are based on performance test. These values
may be changed as a result of additional information or product improvement. NEC should be consulted before using this information for equipment design. This data sheet should not be referred to a
contractual specification.
NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual
property rights of third parties by or arising from use of a device described herein or any other liability arising
from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or others.
3
LD7111 SERIES
LD7111 SERIES OUTLINE (Unit in mm)
(260)
234.7 ± 0.5
A
(208)
33 ± 1.5
(180)
( φ 38)
(147)
5.8±0.1
(177.8)
0.01
φ 6.3 +– 0.05
Detail B
(10)
(125)
133.4 ± 0.25
106 ± 3
( φ 70)
(128)
142.2 ± 0.5
(208)
5.8 ± 0.1
B
4 - φ 5.6
139.7 ± 0.25
252.5 ± 0.25
Electrode
Color of Lead
Heater
Yellow
Heater-Cathode
White
(275)
Lock / Unlock Shaft
Channel Shaft
Body Col & Thermostat
5- φ 5
Terminal
φ 115 ± 1
Thermostat
(Nomally Close)
4-No.4-40 UNC
(111)
17.5 ± 0.3
RF Output
390 MAX.
UG-419 / U
RF Input
36.84 ± 0.3
36.84 ± 0.3
UG-419 / U
View from A
148 ± 2
190 ± 2
(224)
15.5 ± 0.3
(201)
(335)
(7)
(6.5)
(13.4)
(14.65)
26.15 ± 0.3
(136)
27 ± 0.3
(8)
depth 5.8 MAX.