NTE961 Linear Integrated Circuit Voltage Regulator, Negative, 5V, 1A Description: The NTE961 voltage regulator employs current limiting, thermal shutdown, and safe–area compensation which makes it remarkably rugged under most operating conditions. With adequate heat– sinking they can deliver output currents in excess of 1.0 amperes. Features: D No External Components Required D Internal Thermal Overload Protection D Internal Short–Circuit Current Limiting D Output Transistor Safe–Area Compensation Absolute Maximum Ratings: Input Voltage, VIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –35V Input–Output Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25V Internal Power Dissipation (Note 1), PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited Operating Junction Temperature Range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0° to +125°C Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65° to +150°C Lead Temperature (Soldering, 10sec.), TL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +230°C Note 1. For calculations of junction temperature rise due to power dissipation, thermal resistance junction to ambient (ΘJA) is 50°C/W (no heat sink) and 5°C/W (infinite heat sink). Electrical Characteristics: (VOUT = 5V, VIN = –10V, 0°C ≤ TJ ≤ +125°C, IO = 500mA, CIN = 2.2µF, COUT = 1µF, PD ≤ 1.5W unless otherwise specified) Parameter Output Voltage Symbol VO Test Conditions Min Typ Max Unit TJ = +25°C, –4.8 –5.0 –5.2 V 5mA ≤ IO ≤ 1A, P ≤ 15W –4.75 – –5.25 V (–20 ≤ VIN ≤ –7) V Electrical Characteristics Cont’d): (VOUT = 5V, VIN = –10V, 0°C ≤ TJ ≤ +125°C, IO = 500mA, CIN = 2.2µF, COUT = 1µF, PD ≤ 1.5W unless otherwise specified) Parameter Line Regulation Symbol ∆VO Test Conditions TJ = +25°C, Note 2 Min Typ Max Unit – 8 50 mV (–25 ≤ VIN ≤ –7) – 2 15 (–12 ≤ VIN ≤ –8) Load Regulation Quiescent Current Quiescent Current Change ∆VO IQ ∆IQ Vn Ripple Rejection Dropout Voltage Peak Output Current Average Temperature Coefficient of Output Voltage IOMAX mV V TJ = +25°C 5mA ≤ IO ≤ 1.5A – 15 100 mV Note 2 250mA ≤ IO ≤ 750mA – 5 50 mV TJ = +25°C – 1 2 mA With Line – – 0.5 mA (–25 ≤ VIN ≤ –7) Output Noise Voltage V V With Load, 5mA ≤ IO ≤ 1A – – 0.5 mA TA = +25°C, 10Hz ≤ f ≤ 100Hz – 125 – µV f = 120Hz 54 66 – dB (–18 ≤ VIN ≤ –8) V TJ = +25°C, IO = 1A – 1.1 – V TJ = +25°C – 2.2 – A IO = 5mA, 0°C ≤ TJ ≤ 100°C – 0.4 – mV/°C Note 2. Regulation is measured at a constant junction temperature by pulse testing with a low duty cycle. Changes in output voltage due to heating effects must be taken into account. .420 (10.67) Max .110 (2.79) .500 (12.7) Max .147 (3.75) Dia Max .250 (6.35) Max .500 (12.7) Min .070 (1.78) Max GND .100 (2.54) VOUT VIN/Tab