OPTREX DMC-50747NF-AK

First Edit ion
Jul 9, 2001
LCD Module Technical Specification Final Revision
O PTREX
******
Type No.
DMC-50747NF-AK
Approved
by
(Product ion
Div.)
)
Checked
by
(Qualit y
Assurance
Div.)
Checked by (Design Engineering Div.)
)
Prepared by (Product ion Div.)
Table of Contents
1. General Specificat ions.....................................................................................................................................................2
2. Elect rical Specificat ions.................................................................................................................................................3
3. Opt ical Specificat ions ......................................................................................................................................................7
4. I/ O Terminal ............................................................................................................................................................................9
5. Test ..............................................................................................................................................................................................11
6. Appearance St andards ..................................................................................................................................................12
7. Code Syst em of Product ion Lot ............................................................................................................................15
8. Applying Precaut ions ......................................................................................................................................................15
9. Precaut ions Relat ing Product Handling............................................................................................................16
10 . Warrant y ................................................................................................................................................................................17
Revision History
Rev.
Dat e
Page
DMC- 50747NF- AK (AK) No. 2001- 0124
Comment
OPTREX CORPORATION
Page 1/ 17
1. Gener al Spec if ic at ions
Operat ing Temp.
:
min. 0°C ~ max. 50°C
St orage Temp.
:
min. - 20°C ~ max. 70°C
Display Format
:
16 charact ers × 2 lines
Display Font s
:
5 × 7 dots ( 1 charact er )
Viewing Area
:
60.2 (W) × 16.6 (H) mm
Out line Dimensions :
64.2 (W) × 27.6 (H) × 2.2 max. (D) mm
* Wit hout FPC
Weight
:
10g max.
LCD Type
:
NRD- 17533
( F- STN / Black &Whit e- mode / Reflect ive )
Viewing Angle
:
6:00
Dat a Transfer
:
8- bit parallel dat a t ransfer
Backlight
:
None
Addit ional Spec.
:
I/ O FPC Type
Drawings
:
Dimensional Out line UE- 310783
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 2/ 17
2.Elec t r ic al Spec if ic at ions
2.1.Absolut e Maximum Rat ings
VSS=0V
Paramet er
Symbol
Condit ions
Min.
Max.
Unit s
Supply Volt age
VDD- VSS
-
- 0.3
6.0
V
VDD- VOUT
V5=VOUT
- 0.3
16.0
V
VI
-
- 0.3
VDD+0.3
V
(Logic)
Supply Volt age
(LCD Drive)
Input Volt age
2.2.DC Charact erist ics
Ta=25°C, VSS=0V
Paramet er
Symbol
Condit ions
Min.
Typ.
Max.
Unit s
Supply Volt age
VDD- VSS
-
2.4
3.0
3.6
V
(Logic)
Supply Volt age
VDD- VOUT
Shown in 3.1
V
(LCD Drive)
High Level
VIH
VDD=3.0V±10%
0.8´VDD
-
VDD
V
VIL
VDD=3.0V±10%
0
-
0.2´VDD
V
IDD
VDD- VSS=3.0V
-
0.05
0.1
mA
Input Volt age
Low Level
Input Volt age
Supply Current
Note.1
Note.1 : Triple boost ing st at e and checker pat t ern.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 3/ 17
2.3.AC Charact erist ics
2.3.1.Syst em Bus Writ e Charact erist ics 1 (80 series MPU)
VDD=3.0V±10%
Paramet er
Symbol
Min.
Max.
Unit s
t CYC
t AW
t AH
t DS
t DH
t CC
500
-
ns
60
-
ns
30
-
ns
100
-
ns
50
-
ns
Syst em Cycle Time
Address Set up Time
Address Hold Time
Dat a Set up Time
Dat a Hold Time
Cont rol Pulse Width
100
ns
Note 1 : For t he rise and fall of an input signal, set a value not exceeding 25ns.
Note 2 : Every t iming is specified on t he basis of 20%and 80%of VDD.
tAH
A0, CS
tAW
tCYC
tCC
WR
tDS
tDH
D0~D7
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 4/ 17
2.3.2.Syst em Bus Writ e Charact erist ics 2 (68 series MPU)
VDD=3.0V±10%
Paramet er
Syst em Cycle Time
Address Set up Time
Address Hold Time
Dat a Set up Time
Dat a Hold Time
Symbol
Min.
Max.
Unit s
t CYC
t AW
t AH
t DS
t DH
t CC
500
-
ns
60
-
ns
30
-
ns
100
-
ns
50
-
ns
Cont rol Pulse Width
100
ns
Note 1 : For t he rise and fall of an input signal, set a value not exceeding 25ns.
Note 2 : Every t iming is specified on t he basis of 20%and 80%of VDD.
tCYC
E
tAW
tEW
tAH
A0, CS
tDS
tDH
D0~D7
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 5/ 17
2.3.3.Reset Timing
VDD=3.0V±10%
Paramet er
Reset Time
Reset Pulse Width
Symbol
Condit ions
Min.
Max.
Unit s
tR
t RW
t RES
Note 1
1.0
-
ms
Note 2
10
-
ms
Reset St art Time
Note 2
50
ns
Note 1 : t R ( Reset Time ) indicat es t he internal circuit reset completion t ime from t he edge
of t he RES signal. Accordingly, it usually ent ers t he operat ing st at e aft er t R.
Note 2 : Specifies t he minimum pulse width of t he RES signal. It is reset when a signal having
t he pulse width great er t han t RW is ent ered.
VDD
Power Supply
VSS
tRES
tRW
tR
VDD
RES
VSS
All signal timings are based on 20% and 80% of VDD signals.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 6/ 17
3.Opt ic al Spec if ic at ions
3.1.LCD Driving Volt age
Paramet er
Symbol
Recommended
LCD Driving Volt age
VDD- VOUT
Condit ions
Min.
Typ.
Max.
Unit s
Ta= 0°C
-
-
7.3
V
Ta=25°C
6.2
6.5
6.8
V
Note 1
Ta=50°C
5.7
V
Note 1 :
Volt age (Applied act ual waveform t o LCD Module) for t he best cont rast . The
range of minimum and maximum shows t olerance of t he operat ing volt age. The
specified cont rast rat io and response t ime are not guarant eed over t he ent ire range.
3.2.Opt ical Charact erist ics
Ta=25°C, 1/ 16 Dut y, 1/ 5 Bias, VD=6.5V (Note 4), q= 0°, f= - °
Paramet er
Cont rast Rat io
Symbol
Condit ions
Min.
Typ.
Max.
CR
q= 0°, f= - °
-
7
-
Note 1
Viewing Angle
Response
Unit s
Shown in 3.3
Rise Note 2
TON
-
-
50
100
ms
Time Decay Note
TOFF
85
170
ms
Note 1 : 3 Cont rast rat io is definded as follows.
CR = LOFF / LON
LON : Luminance of t he ON segment s
LOFF : Luminance of t he OFF segment s
Note 2 :
The t ime t hat t he luminance level reaches 90%of t he sat urat ion level from
0%when ON signal is applied.
Note 3 :
The t ime t hat t he luminance level reaches 10%of t he sat urat ion level from
100%when OFF signal is applied.
Note 4 :
Definit ion of Driving Volt age VD
Assuming t hat t he t ypical driving waveforms shown below are applied t o t he
LCD Panel at 1/ A Dut y - 1/ B Bias ( A : Dut y Number, B : Bias Number ).
Driving volt age VD is definded as follows.
VD = (Vt h1+Vt h2) / 2
Vt h1 :The volt age VO- P t hat should provide 50%of t he sat urat ion level in t he
luminance at t he segment which t he ON signal is applied t o.
Vt h2 :The volt age VO- P t hat should provide 50%of t he sat urat ion level in t he
luminance at t he segment which t he OFF signal is applied t o.
VO-P
( B-2 )´ VO-P / B
1 / ( fF ´A )
<ON SIGNAL>
DMC- 50747NF- AK (AK) No. 2001- 0124
1 / fF
<OFF SIGNAL>
OPTREX CORPORATION
Page 7/ 17
3.3.Definit ion of Viewing Angle and Opt imum Viewing Area
* Point · shows t he point where cont rast rat io is measured. : q= 0°, f= - °
* Driving condit ion : 1/ 16 Dut y, 1/ 5 Bias, VD=6.5V, f F=100Hz
90°
45°
135°
q
f
10 20 30 40 50
180°
90°
(f = 0°)
q
f
180°
225°
0°
315°
270°
270°
* Area
shows t yp. CR³2
3.4.Syst em Block Diagram
Temperature Chamber
Rotation Table ( q,f )
Photometer
#1980A WB
f
LCD
Optical Fiber
q
Computer
Control Unit &
Waveform Generator
Halogen bulb
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 8/ 17
4.I/ O T er minal
4.1.Pin Assignment
CN1
No.
Symbol
Level
1
A0
H/ L
H : D0~D7 are display dat a. L : D0~D7 are a command.
2
WR
H/ L
80 family MPU : WR Signal Input
(E)
Funct ion
L : Act ive
68 family MPU : Enable Clock Input
3
CS
H/ L
Chip select signal. L : Act ive
4
D7
H/ L
Dat a Bus Line
5
D6
H/ L
Dat a Bus Line
6
D5
H/ L
Dat a Bus Line
7
D4
H/ L
Dat a Bus Line
8
D3
H/ L
Dat a Bus Line / Non- connect ion at 4- bit operat ion
9
D2
H/ L
Dat a Bus Line / Non- connect ion at 4- bit operat ion
10
D1
H/ L
Dat a Bus Line / Non- connect ion at 4- bit operat ion
11
D0
H/ L
Dat a Bus Line / Non- connect ion at 4- bit operat ion
12
VDD
-
Supply Volt age + 3V
13
VSS
-
Supply Volt age 0V (GND)
14
V5
-
Connect t o VDD and a capacit or of 0.1~4.7mF(Cf.chap.4.2)
15
V4
-
Connect t o a capacit or of 0.1~4.7mF (Cf.chap.4.2)
16
V3
-
Connect t o a capacit or of 0.1~4.7mF (Cf.chap.4.2)
17
V2
-
Connect t o a capacit or of 0.1~4.7mF (Cf.chap.4.2)
18
V1
-
Connect t o a capacit or of 0.1~4.7mF (Cf.chap.4.2)
19
VOUT
-
Supply Volt age (LCD Drive)
20
VSS
-
Supply Volt age 0V ( GND)
21
VDD
-
Supply Volt age + 3V
22
P/ S
H/ L
H : Parallel Dat a Transfer, L : Serial Dat a Transfer
23
IF
H/ L
Int erface Dat a Lengt h Select .H : 8- bit Parallel,L : 4- bit Parallel
24
RES
H/ L
In case of a 68 series MPU,init ializat ion can be performed by
changing RES
. In case of an 80 series MPU,init ializat ion
can be performed by changung
.
A reset operat ion is performed by edge sensing of t he RES
signal.
An interfase t ype for t he 68/ 80 seriees MPU is select ed by
Input level aft er init ializat ion.
²L² : 68 series MPU interface.
²H² : 80 series MPU interface.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 9/ 17
4.2.Example of Power Supply
It is recommended t o apply a potent iomet er for t he cont rast adjust due t o
t he t olerance of t he driving volt age and it s t emperat ure dependence.
VDD
MODULE
VDD (+3V)
VSS
GND (0V)
VR
VSS
V5
V4
V3
V2
V1
VOUT (-7V)
C5
C4
C3
C2
C1
VR=10~20KW
C1~C5:0.1~4.7 m
F
4.3.Block Diagram
DB7
8
~
DB0
COM 14
RES
LCDP
16 Characters ´ 2 Lines
IF
SEG 80
P/S
Control LSI
CS
WR
SED1233DGB
A0
VOUT
5
V1~V5
VDD
VSS
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 10/ 17
5.T est
No change on display and in operat ion under t he following t est condit ion.
Condit ions:
No.
Unless otherwise specified, t est s will be conduct ed under t he following condit ion.
Temperat ure: 20±5°C
Humidit y : 65±5%RH
t est s will be not conduct ed under funct ioning st at e.
Paramet er
Condit ions
Notes
1
High Temperat ure Operat ing 50°C±2°C, 96hrs (operat ion st at e)
2
Low Temperat ure Operat ing
0°C±2°C, 96hrs (operat ion st at e)
2
3
High Temperat ure St orage
70°C±2°C, 96hrs
3
4
Low Temperat ure St orage
- 20°C±2°C, 96hrs
2,3
5
Damp Proof Test
40°C±2°C,90~95%RH, 96hrs
2,3
6
Heat Shock Test
- 25°C (30min) ® 25°C (5min) ® 70°C (30min)
1
2
® 25°C (5min) 5 cycles
7
Vibrat ion Test
Total fixed amplit ude : 1.5mm
4
Vibrat ion Frequuency : 10~55HZ
One cycle 60seconds t o 3direct ions of X,Y,Z
for
Each 15 minut es
Note 1 : It shhould be checked at t he act ual driving condit ion under t he high t emperat ure.
Note 2 : No dew condensat ion t o be observed.
Note 3 : The funct ion t est shall be conduct ed aft er 4 hours st orage at t he normal
t emperat ure and humidit y aft er removed from t he t est chamber.
Note 4 : Vibrat ion t est will be conduct ed t o t he product it self wit hout put t ing it in a
cont ainer.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 11/ 17
6.Appear anc e St andar ds
6.1.Inspect ion condit ions
The LCD shall be inspect ed under 40W whit e fluorescent light .
The dist ance bet ween t he eyes and t he sample shall be more t han 30cm.
All direct ions for inspect ing t he sample should be wit hin 45°against perpendicular line.
45°
6.2.Definit ion of applicable Zones
X
X
X
A Zone
B Zone
X
C Zone
X : Maximum Seal Line
A Zone : Act ive display area
B Zone : Out of act ive display area ~ Maximum seal line
C Zone : Rest part s
A Zone + B Zone = Validit y viewing area
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 12/ 17
6.3.St andards
No.
1
Paramet er
Black and
Crit eria
(1) Round Shape
Whit e Spots,
Foreign
Zone
Accept able Number
Dimension (mm)
A
B
C
*
*
*
0.1 < D £ 0.2
5
5
*
0.2 < D £ 0.3
0
1
*
0.3 < D
0
0
*
D £ 0.1
Subst ances
D = ( Long + Short ) / 2
* : Disregard
(2) Line Shape
Zone
X(mm)
Y(mm)
Accept able Number
A
B
C
-
0.02³W
*
*
*
2.0³L
0.03³W
3
3
*
1.0³L
0.04³W
1
2
*
1.0³L
0.05³W
0
2
*
-
0.05<W
X : Lengt h Y : Width
In t he same way (1)
* : Disregard
Total defect s shall not exceed 5.
2
Air Bubbles
(bet ween glass
& polarizer)
Zone
Dimension (mm)
Accept able Number
A
B
C
*
*
*
0.15< D £0.3
2
3
*
0.3 < D £0.5
1
2
*
0.5 < D £1.0
0
1
*
D £ 0.15
* : Disregard
Total defect s shall not exceed 3.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 13/ 17
No.
Paramet er
3
The Shape of Dot
Crit eria
(1) Dot Shape (wit h Dent )
0.15³
As per t he sket ch of left hand.
(2) Dot Shape (wit h Project ion)
Should not be connect ed t o next dot.
(3) Pin Hole
X
(X+Y) / 2£0.2mm
Y
(Less t han 0.1mm is no count ed.)
Total defect s shall not exceed 5.
4
5
Polarizer
Scrat
Polarizer
ches Dirt s
Not t o be conspicuous defect s.
If t he st ains are removed easily from LCDP surface, t he module
isnot
not defect ive.
6
Color Variat ion
Not t o be conspicuous defect s.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 14/ 17
7.Code Syst em of Pr oduc t ion L ot
The product ion lot of module is specified as follows.
Fact ory Number (Numeral)
Fact ory Code (Alphabet )
Product ion Week (1~5)
Product ion Mont h (1~9, X, Y, Z)
Product ion Year (Lower 2 digit s)
8.Applying Pr ec aut ions
Please cont act us when quest ions and/ or new problems not specified in t his specificat ions
arise.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 15/ 17
9.Pr ec aut ions Relat ing Pr oduc t Handling
The Following precaut ions will guide you in handling our product correct ly.
1) Liquid cryst al display devices
1. The liquid cryst al display device panel used in t he liquid cryst al display module is made
of plat e glass. Avoid any st rong mechanical shock. Should t he glass break handle it
wit h care
2. The polarizer adhering t o t he surface of t he LCD is made of a soft mat erial.
Guard against scrat ching it .
2) Care of t he liquid cryst al display module against st at ic elect ricit y discharge.
1. When working wit h t he module, be sure t o ground your body and any elect rical
equipment you may be using. We st rongly recommend t he use of ant i st at ic mat s
( made of rubber ), t o protect work t ables against t he hazards of elect rical shock.
2. Avoid t he use of work clot hing made of synt het ic fibers. We recommend cott on
clot hing or other conduct ivit y- t reat ed fibers.
3. Slowly and carefully remove t he prot ect ive film from t he LCD module, since t his
operat ion can generat e st at ic elect ricit y.
3) When t he LCD module alone must be st ored for long periods of t ime:
1. Protect t he modules from high t emperat ure and humidit y.
2. Keep t he modules out of direct sunlight or direct exposure t o ult raviolet rays.
3. Protect t he modules from excessive ext ernal forces.
4) Use t he module wit h a power supply t hat is equipped wit h an overcurrent protect or
circuit , since t he module is not provided wit h t his protect ive feat ure.
5) Do not ingest t he LCD fluid it self should it leak out of a damaged LCD module. Should
hands or clot hing come in cont act wit h LCD fluid, wash immediat ely wit h soap.
6) Conduct ivit y is not guarant eed for models t hat use met al holders where solder
connect ions bet ween t he met al holder and t he PCB are not used. Please cont act us t o
discuss appropriat e ways t o assure conduct ivit y.
7) For models which use CFL:
1. High volt age of 1000V or great er is applied t o t he CFL cable connect or area.
Care should be t aken not t o t ouch connect ion areas t o avoid burns.
2. Protect CFL cables from rubbing against t he unit and t hus causing t he wire jacket t o
become worn.
3.The use of CFLs for ext ended periods of t ime at low t emperat ures will significant ly
short en t heir service life.
8) For models which use t ouch panels:
1.Do not st ack up modules since t hey can be damaged by component s on neighboring
modules.
2.Do not place heavy object s on t op of t he product . This could cause glass breakage.
9) For models which use COG,TAB,or COF:
1.The mechanical st rengt h of t he product is low since t he IC chip faces out unprotect ed
from t he rear.
Be sure t o protect t he rear of t he IC chip from ext ernal forces.
2.Given t he fact t hat t he rear of t he IC chip is left exposed, in order t o protect t he unit
from elect rical damage, avoid installat ion configurat ions in which t he rear of t he IC
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 16/ 17
chip runs t he risk of making any elect rical cont act .
10) Models which use flexible cable, heat seal, or TAB:
1.In order t o maintain reliabilit y, do not t ouch or hold by t he connect or area.
2.Avoid any bending, pulling, or other excessive force, which can result in broken
connect ions.
10.War r ant y
This product has been manufact ured t o your company’ s specificat ions as a part for use in
your company’ s general elect ronic product s. It is guarant eed t o perform according t o delivery
specificat ions. For any ot her use apart from general elect ronic equipment , we cannot
t ake responsibilit y if t he product is used in medical devices, nuclear power cont rol
equipment , aerospace equipment , fire and securit y syst ems, or any other applicat ions in
which t here is a direct risk t o human life and where ext remely high levels of reliabilit y
are required. If t he product is t o be used in any of t he above applicat ions, we will need
t o ent er into a separat e product liabilit y agreement .
1. We cannot accept responsibilit y for any defect , which may arise from addit ional
manufact uring of t he product (including disassembly and reassembly), aft er product
delivery.
2. We cannot accept responsibilit y for any defect , which may arise aft er t he applicat ion of
st rong ext ernal force t o t he product .
3. We cannot accept responsibilit y for any defect , which may arise due t o t he applicat ion
of st at ic elect ricit y aft er t he product has passed your company’ s accept ance
inspect ion procedures.
4. When t he product is in CFL models, CFL service life and bright ness will vary according
t o t he performance of t he invert er used, leaks, et c. We cannot accept responsibilit y
for product performance, reliabilit y, or defect , which may arise.
5. We cannot accept responsibilit y for int ellect ual propert y of a t hird part y, which may
arise t hrough t he applicat ion of our product t o your assembly wit h except ion t o t hose
issues relat ing direct ly t o t he st ruct ure or met hod of manufact uring of our product .
6. Opt rex will not be held responsible for any qualit y guarant ee issue for defect product s
judged as Opt rex- origin longer t han 2 (t wo) years from Opt rex product ion or 1(one)
year from Opt rex, Opt rex America, Opt rex Europe, Display LC delivery which ever
comes lat er.
DMC- 50747NF- AK (AK) No. 2001- 0124
OPTREX CORPORATION
Page 17/ 17