POWEREX RM400HA-24S

RM400HA-24S
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Super Fast Recovery
Single Diode Module
400 Amperes/1200 Volts
Description:
Powerex Super-Fast Recovery
Single Diode Modules are
designed for use in applications
requiring fast switching. The
modules are isolated for easy
mounting with other components
on common heatsinks.
OUTLINE DRAWING
A
B
H
K
A
C
CL
M - M6 THD
(2 TYP.)
D
H
K - DIA.
(4 TYP.)
G
CL
Features:
L
J
M Isolated Mounting
F
E
CONNECTION DIAGRAM
A
RM400HA-24S
Super Fast Recovery
Single Diode Module
400 Amperes/1200 Volts
M Planar Chips
Applications:
M Inverters
K
M Choppers
Outline Drawing
M Switching Power Supplies
Dimension
Inches
Millimeters
A
4.25
108
B
3.661±0.012
93.0±0.3
C
2.44 Max.
62.0 Max.
D
1.890±0.012
48.0±0.3
E
1.63 Max.
41.5 Max.
M Free Wheeling
Ordering Information:
Select the complete ten digit
module part number you desire
from the table below.
Example: RM400HA-24S is a
1200 Volt, 400 Ampere, Super
Fast Recovery Single Diode
Module.
F
1.42 Max.
36.0 Max.
G
1.14
29.0
H
0.63
16.0
J
0.26
6.5
Type
Current Rating
Amperes
Voltage
Volts (x50)
K
0.256 Dia.
Dia. 6.5
RM
400
24
L
0.12
3.0
M
M6 Metric
M6
D-37
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
RM400HA-24S
Super Fast Recovery
Single Diode Module
400 Amperes/1200 Volts
Absolute Maximum Ratings
Characteristics
Symbol
Peak Reverse Blocking Voltage
VRRM
VRSM
1200
Volts
1350
Volts
VR(DC)
IF(DC)
960
Volts
400
Amperes
8000
Amperes
Transient Peak Reverse Blocking Voltage (Non-Repetitive), t < 5ms
DC Reverse Blocking Voltage
DC Current, TC = 90°C
Peak Half-Cycle Surge (Non-Repetitive) On-State Current (60Hz)
I2t (for Fusing), 8.3 milliseconds
Junction Temperature
Maximum Mounting Torque M6 Mounting Screw
Tj
TSTG
—
Maximum Mounting Torque M6 Terminal Screw
—
Storage Temperature
Module Weight (Typical)
V Isolation
D-38
IFSM
I2t
—
VRMS
RM400HA-24S
260,000
Units
A2sec
-40 to 150
°C
-40 to 125
°C
26
kg.-cm.
26
kg.-cm.
460
Grams
2500
Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
RM400HA-24S
Super Fast Recovery
Single Diode Module
400 Amperes/1200 Volts
Electrical and Thermal Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Blocking State Maximums
Reverse Leakage Current, Peak
IRRM
Tj = 150°C, VRRM = Rated
Conducting State Maximums
Peak On-State Voltage
VFM
Tj = 25°C, IFM = 400A
2.0
Volts
trr
IFM = 400A, Tj = 150°C
di/dt = -400A/ms, VR = 500V
0.4
ms
Qrr
IFM = 400A, Tj = 150°C
di/dt = -400A/ms, VR = 500V
Switching Minimums
Reverse Recovery Time
Reverse Recovery Charge
Thermal Maximums
Thermal Resistance, Junction-to-Case
Thermal Resistance, Case-to-Sink
Ru(J-C)
Ru(C-S)
RM400HA-24S
30
80
Units
mA
mC
Per Module
0.1
°C/Watt
Per Module
0.04
°C/Watt
D-39
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
RM400HA-24S
Super Fast Recovery
Single Diode Module
400 Amperes/1200 Volts
FORWARD VOLTAGE DROP
CHARACTERISTICS (TYPICAL)
Irr
101
102
Qrr
101
100
trr
100
101
102
103
103
REVERSE RECOVERY TIMES, trr, (µs)
VR = 600V
IF = 400A/µs
Tj = 25oC
Tj = 125oC
10-1
104
FORWARD CURRENT, IF, (AMPERES)
REVERSE RECOVERY, Irr, (AMPERES), Qrr, (µC)
103
102
101
0.4
1.6
2.0
2.4
MAXIMUM ALLOWABLE PEAK SURGE
(NON-REPETITIVE) CURRENT
10000
0.10
MAXIMUM PEAK SURGE (NON-REPETITIVE)
CURRENT, IFSM, (AMPERES)
TRANSIENT THERMAL IMPEDANCE, Zth(J-C)(t), (oC/WATT)
1.2
FORWARD VOLTAGE DROP, VF, (VOLTS)
TRANSIENT THERMAL IMPEDANCE
CHARACTERISTICS (JUNCTION-TO-CASE)
0.08
0.06
0.04
0.02
8000
6000
4000
2000
0
10-2
10-1
TIME, t, (SECONDS)
D-40
0.8
100
101
100
102
103
Tj = 25oC
di/dt, (AMPERES/µs)
0
10-3
REVERSE RECOVERY VS FORWARD CURRENT
CHARACTERISTICS (TYPICAL)
REVERSE RECOVERY, Irr, (AMPERES), Qrr, (µC)
102
101
CYCLES AT 60 HZ
102
Tj = 25oC
Tj = 125oC
VR = 600V
-di/dt = 800A/µs
102
Irr
101
Qrr
101
100
trr
100
101
102
103
FORWARD CURRENT, IF (AMPERES)
10-1
104
REVERSE RECOVERY TIMES, trr, (µs)
REVERSE RECOVERY VS di/dt
CHARACTERISTICS (TYPICAL)