54AC11253, 74AC11253 DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SCAS041A – MAY 1988 – REVISED APRIL 1993 • • • • • • 54AC11253 . . . J PACKAGE 74AC11253 . . . D OR N PACKAGE (TOP VIEW) Permits Multiplexing From N Lines to One Line Performs Parallel-to-Serial Conversion Flow-Through Architecture Optimizes PCB Layout Center-Pin VCC and GND Configurations Minimize High-Speed Switching Noise EPIC (Enhanced-Performance Implanted CMOS) 1-mm Process Package Options Include Plastic SmallOutline Packages, Ceramic Chip Carriers, and Standard Plastic and Ceramic 300-mil DIPs A B 1Y GND 2Y 1G 2G 2C3 t 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 1C0 1C1 1C2 1C3 VCC 2C0 2C1 2C2 54AC11253 . . . FK PACKAGE (TOP VIEW) 1C2 1C3 NC V CC 2C0 description Each of these data selectors/multiplexers contains inverters and drivers to supply full binary decoding data selection to the AND-OR gates. Separate output control inputs are provided for each of the two four-line sections. The 54AC11253 is characterized for operation over the full military temperature range of – 55°C to 125°C. The 74AC11253 is characterized for operation from – 40°C to 85°C. SELECT INPUTS B A C0 C1 C2 C3 OUTPUT CONTROL G X X X X X X H Z L L L X X X L L L L H X X X L H L H X L X X L L L H X H X X L H DATA INPUTS OUTPUT Y L X X L X L L H L X X H X L H H H X X X L L L H H X X X H L H Address inputs A and B are common to both sections. 5 17 6 16 7 15 8 14 9 10 11 12 13 2C1 2C2 NC 2C3 2G logic symbol† A B 1C0 1C1 1C2 H 3 2 1 20 19 18 NC – No internal connection 1G FUNCTION TABLE 4 1Y GND NC 2Y 1G The three-state outputs can interface with and drive data lines of bus-organized systems. With all but one of the common outputs disabled (at a high-impedance state), the low-impedance of the single enabled output will drive the bus line to a high or low logic level. Each output has its own strobe (G). The output is disabled when its strobe is high. 1C1 1C0 NC A B 1C3 2G 2C0 2C1 2C2 2C3 1 2 6 16 0 1 13 0 3 MUX EN 0 15 14 G 1 3 1Y 2 3 7 11 10 5 9 2Y 8 † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, J, and N packages. EPIC is a trademark of Texas Instruments Incorporated. Copyright 1993, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–1 54AC11253, 74AC11253 DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SCAS041A – MAY 1988 – REVISED APRIL 1993 logic diagram (positive logic) 1G 1C0 1C1 6 16 15 3 Data 1 1C2 1C3 B 1Y 14 13 2 Select A 2C0 2C1 1 11 10 Data 2 5 2C2 2C3 2G 9 2Y 8 7 Pin numbers shown are for the D, J, and N packages. absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 100 mA Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded provided the input and output current ratings are observed. 2–2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 54AC11253, 74AC11253 DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SCAS041A – MAY 1988 – REVISED APRIL 1993 recommended operating conditions 54AC11253 VCC VIH Supply voltage VCC = 3 V VCC = 4.5 V High-level input voltage VCC = 5.5 V VCC = 3 V VIL VI VO IOH IOL Low-level input voltage NOM MAX 3 5 5.5 Dt /Dv Input transition rise or fall rate TA Operating free-air temperature 3 5 5.5 3.15 3.85 UNIT V V 3.85 0.9 0.9 1.35 1.35 1.65 1.65 VCC VCC 0 Low-level output current MAX 3.15 VCC = 3 V VCC = 4.5 V High-level output current NOM 2.1 0 Output voltage MIN 2.1 VCC = 4.5 V VCC = 5.5 V Input voltage 74AC11253 MIN 0 VCC VCC 0 –4 –4 – 24 – 24 VCC = 5.5 V VCC = 3 V – 24 – 24 12 12 VCC = 4.5 V VCC = 5.5 V 24 24 24 24 V V V mA mA 0 10 0 10 ns/ V – 55 125 – 40 85 °C electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS IOH = – 50 mA VOH IOH = – 4 mA IOH = – 24 mA IOH = – 50 mA† IOH = – 75 mA† MIN TA = 25°C TYP MAX 54AC11253 MIN MAX IOL = 24 mA MIN 2.9 2.9 2.9 4.5 V 4.4 4.4 4.4 5.5 V 5.4 5.4 5.4 3V 2.58 2.4 2.48 4.5 V 3.94 3.7 3.8 5.5 V 4.94 4.7 4.8 MAX V 3.85 3V 0.1 0.1 0.1 4.5 V 0.1 0.1 0.1 5.5 V 0.1 0.1 0.1 3V 0.36 0.5 0.44 4.5 V 0.36 0.5 0.44 5.5 V 0.36 0.5 0.44 IOL = 50 mA† IOL = 75 mA† 5.5 V IOZ II VO = VCC or GND VI = VCC or GND 5.5 V ± 0.5 ± 10 ±5 5.5 V ± 0.1 ±1 ±1 ICC Ci VI = VCC or GND, VI = VCC or GND 8 160 80 1.65 5.5 V 5V 3.5 Co VO = VCC or GND 5V 8 † Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. POST OFFICE BOX 655303 V 1.65 5.5 V IO = 0 UNIT 3.85 5.5 V IOL = 12 mA 74AC11253 3V 5.5 V IOL = 50 mA VOL VCC • DALLAS, TEXAS 75265 mA mA mA pF pF 2–3 54AC11253, 74AC11253 DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SCAS041A – MAY 1988 – REVISED APRIL 1993 switching characteristics over recommended operating free-air temperature range, VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A or B Y tPLH tPHL Data (Any C) Y tPZH tPZL G Y tPHZ tPLZ G Y MIN TA = 25°C TYP MAX 54AC11253 74AC11253 MIN MAX MIN MAX 1.5 7.1 9.7 1.5 11.7 1.5 11 1.5 7.5 10.1 1.5 12.1 1.5 11.4 1.5 6.8 8.3 1.5 9.9 1.5 9.3 1.5 7 8.8 1.5 10.3 1.5 9.6 1.5 4.8 6.2 1.5 7.2 1.5 6.8 1.5 5.8 7.4 1.5 8.7 1.5 8.2 1.5 5 6.3 1.5 7 1.5 6.7 1.5 5.2 6.5 1.5 7.2 1.5 6.9 UNIT ns ns ns ns switching characteristics over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A or B Y tPLH tPHL Data (Any C) Y tPZH tPZL G Y tPHZ tPLZ G Y MIN TA = 25°C TYP MAX 54AC11253 74AC11253 MIN MAX MIN MAX 1.5 4.9 7 1.5 8.3 1.5 7.9 1.5 5.2 7.3 1.5 8.7 1.5 8.2 1.5 4.5 5.9 1.5 7.1 1.5 6.6 1.5 4.8 6.3 1.5 7.3 1.5 6.9 1.5 3.4 4.6 1.5 6.4 1.5 5.1 1.5 4 5.3 1.5 6.1 1.5 5.8 1.5 4.7 6 1.5 6.6 1.5 6.3 1.5 4.6 5.9 1.5 6.4 1.5 6.2 UNIT ns ns ns ns operating characteristics, VCC = 5 V, TA = 25°C PARAMETER Cpd d 2–4 TEST CONDITIONS Power dissipation capacitance per multiplexer Outputs enabled Outputs disabled POST OFFICE BOX 655303 CL = 50 pF, pF • DALLAS, TEXAS 75265 f = 1 MHz TYP 31 11 UNIT pF 54AC11253, 74AC11253 DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SCAS041A – MAY 1988 – REVISED APRIL 1993 PARAMETER MEASUREMENT INFORMATION 2 × VCC S1 500 Ω From Output Under Test Open GND LOAD CIRCUIT Output Control (low-level enabling) VCC 50% 50% 0V tPLH tPHL VOH Output S1 Open 2 × VCC GND 50% 50% 500 Ω CL = 50 pF (see Note A) Input (see Note B) TEST tPLH/tPHL tPLZ/tPZL tPHZ/tPZH 50% VCC 50% VCC VOL VCC 0V tPZL Output Waveform 2 S1 at GND (see Note C) [ VCC tPLZ Output Waveform 1 S1 at 2 × VCC (see Note C) 50% VCC VOL tPHZ tPZH VOLTAGE WAVEFORMS 20% VCC 50% VCC 80% VCC VOH [0V VOLTAGE WAVEFORMS NOTES: A. CL includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns. C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. D. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–5 54AC11253, 74AC11253 DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SCAS041A – MAY 1988 – REVISED APRIL 1993 2–6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated