■ Features
■ Outline Dimensions
( Unit : mm )
+ 0.5
0.3
1. Less sensitive to fluorescent lamp driven
by inverter
2. Improved anti-electromagnetic noise characteristic by mesh type light detecting
window.
3. Various B.P.F ( Band Pass Filter ) frequency
4. Built-in voltage regulator circuit
15 -
3.6
13.25
❈1
3.65 ± 0.5
❈1
7.5 ± 0.5
2.4
❈2
2.54
8
1 2 3
❈2
2.54
2.54
1.7
❈2
2.1
2.54
*2
5.5 ± 0.5
Recommended drilling as viewed from the soldering face.
* Tolerance :± 0.3mm
❈ 1 Detector center
❈ 2 The dimension of connector base
■ Absolute Maximum Ratings
Parameter
Supply voltage
*1
Operating temperature
Storage temperature
*2
Soldering temperature
0.
1. TVs
2. VCRs
3. CATV set top boxes
4. BS receivers
1.4
φ
3-
Rib
14.2
4.3
+ 0.5
0.3
15.1 -
■ Applications
1 2 3
1 Vout
2 Vcc
3 GND
2
Symbol
V CC
T opr
S stg
T sol
( Ta = 25˚C )
Rating
0 to 6.3
- 10 to + 70
- 20 to + 70
260
Unit
V
˚C
˚C
˚C
*1 No dew formation
*2 For 5 seconds
■ Recommended Operations Conditions
Parameter
Supply voltage
Symbol
V CC
Value
4.7 to 5.3
Unit
V
■ Electrical Characteristics
Parameter
Dissipation current
High level output voltage
Low level output voltage
High level pulse width
Low level pulse width
B. P. F. center frequency
( Ta = 25˚C, VCC = + 5V )
Symbol
I CC
V OH
V OL
T1
T2
fo
Conditions
No input light
*3
-
MIN.
V CC - 0.5
400
400
-
TYP.
*4
40
MAX.
5.0
0.45
800
800
-
*3 The burst wave as shown in the following figure shall be transmitted by the transmitter shown in Fig. 1.
*4 Diversified models with a different B. P. F. frequency, as shown in a separate table, are also available.
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device. ”
Unit
mA
V
V
µs
kHz
GP1U78Q Series
600 µ s
600 µ s
The value of fO is shown in a separate table.
Duty 50%
■ Model Line-up
Model No.
GP1U78Q
GP1U780Q
GP1U781Q
GP1U782Q
GP1U783Q
B.P.F. frequency
40
36
38
36.7
32.75
GP1U787Q
56.8
Unit
kHz
■ Internal Block Diagram
Vout
Amp
Limiter
B.P.F.
Demodulator Integrator Comparator
Vcc
GND
GP1U78Q Series
■ Performance
Using the transmitter shown in Fig. 1, the output signal of the light detecting unit is good enough
to meet the following items in the standard optical system in Fig. 2.
( 1 ) Linear reception distance characteristics
When L= 0.2 to 6.5m, Ee<10 lx and φ = 0˚ in Fig. 2, the output signal shall meet the electrical
characteristcs in the attached list.
( 2 ) Sensitivity angle reception distance characteristics
When L= 0.2 to 4.5m, Ee< 10 lx and φ <= 30˚ in Fig. 2, the output signal shalmeet the electrical
characteristics in the attached list.
( 3 ) Anti outer peripheral light reception distance characteristics
When L= 0.2 to 3m, Ee <= 300 lx and φ = 0˚ in Fig. 2, the output signal shall meet the electrical
characteristics in the attached list.
20cm
10k Ω
Transmitter (GL521 used )
Duty 50 %
Center frequency (fo )
depends on the attached
model list.
10 µ F
10k Ω
PD49PI
+ 5V
Vout
Oscilloscope
Fig. 1. Transmitter
In the above figure, the transmitter should be set so that the output V out can be 40mV PP .
However, the PD49PI to be used here should be of the short-circuit current I SC = 2.6 µ A at E V =
100 lx.
(E V is an illuminance by CIE standard light source A ( tungsten lamp ) . )
Light detector face
illuminance : Ee
Reception distance : L
φ
φ
Transmitter
( φ indicates horizontal and
vertical directions. )
Fig. 2. Standard optical system
Vout
GP1U78Q Series
■ Precautions for Use
( 1 ) Use the light emitting unit ( remote control transmitter ) , in consideration of performance,
characteristics and operating condition of light emitting device and the characteristics of
the light detecting unit.
( 2 ) Pay attention to a malfunction of the light detecting unit when the surface is stained with
dust and refuse. Care must be taken not to touch the light detector surface. If it should be
dirty, wipe off with soft cloth so as to prevent scratch. In case some solvents are required,
use metyl alcohol, ethyl alcohol or isoprophyl alcohol. Also, protect the light detecting unit
against flux and others.
( 3 ) The shield case shall be grounded on PWB pattern.
( 4 ) Do not apply unnecessary force to the terminals and case form outside.
( 5 ) Do not push the light detector surface ( photodiode ) from outside.
( 6 ) To avoid the electorstatic breakdown of IC, handle the unit under the condition of grounding with human body, soldering iron, etc.
( 7 ) In case of adopting the infrared light detecting unit for the wireless remote control, use it
in accordance with the transmission scheme and the signal format recommended in “ Countermeasures for malfunction prevention of home appliances with infrared remote control ”
issued form Japan Association of Electrical Home Appliances ( AEHA ) in July 1987.
( 8 ) As for other general cautions, refer to the chapter “ Precautions for Use” ( Page 78 to 93 ) .