For assistance or to order, call Application Notes Mechanical Outline Product Selector Guide (800) 531-5782 24V PT3100 Series 15 WATT 24V TO 5V/12V/15V ISOLATED DC-DC CONVERTER • Power Density 15 Watts/in3 • Wide Input Voltage Range 18V to 40V • 81% Efficiency • 500 VDC Isolation • Small Footprint • No External Components Required Power Trends’ PT3104A (5V), PT3105A (12V) and PT3106A (15V) Revised 5/15/98 Isolated DC-DC Converters advance the state-of-the-art for board-mounted converters by employing high switching frequencies greater than 650 KHz and planar magnetics and surface-mount construction. They feature the industry’s smallest footprint, a power density of 15 Watts/in3, and operate at 80% efficiency. They are designed for Telecom, Industrial, Computer, Medical, and other distributed power applications requiring input-to-output isolation. Standard Application On/Off 1 +Vin 3 -Vin 2 PT3100 5 +Vout 4 -Vout Specifications Pin-Out Information Characteristics (Ta=25°C unless noted) Symbols Conditions Output Current Io Over Vin range, Current Limit On/Off Standby Current Pin Function Min Typ Max Units 1 Vo = 5V Vo = 12V Vo = 15V 0 0 0 — — — 3.0 1.25 1.0 A A A Remote ON/OFF 2 -Vin Vo = 5V Vo = 12V Vo = 15V — — — 4.0 1.75 1.4 — — — A A A 3 +Vin 4 -Vout 7 10 mA 5 +Vout 6 Do not connect PT3100 SERIES Icl Vin = 18V, Iin standby Vin = 24V, Pin 1 = -Vin — Short Circuit Current Isc Vin = 24V, — — — 6.25 2.5 2.0 — — — A A A Inrush Current Iir tir Vin = 24V @ max Io On start-up — — 1.0 1.0 2.0 5.0 A mSec Input Voltage Range Vin Io = 0.1 to max Io 18.0 24.0 40.0 V Output Voltage Tolerance ∆Vo Over Vin Range TA= -20°C to +70°C — ±1.0 ±2.0 %Vo Ripple Rejection RR Over Vin range @ 120 Hz — 60 — dB Line Regulation Regline Over Vin range @ max Io — ±0.2 ±1.0 %Vo Load Regulation Regload 10% to 100% of Io max — ±0.4 ±1.0 %Vo Vo Ripple/Noise Vn Vin=24V, Io=3.0A, Vo=5V Vin=24V, Io=1.25A, Vo=12V Vin=24V, Io=1.25A, Vo=15V — — — 75 75 100 100 150 200 mVpp mVpp mVpp Transient Response ttr 50% load change Vo over/undershoot — — 125 3.0 200 5.0 µSec %Vo Efficiency η Vin=24V, Io=3.0A, Vo=5V Vin=24V, Io=1.25A, Vo=12V Vin=24V, Io=1A, Vo=15V — — — 80 80 81 — — — % % % Switching Frequency ƒo Over Vin and Io, Vo=5V Vo=12V/15V 800 600 850 650 900 700 kHz kHz Recommended Operating Temperature Range Ta Vin = 24V @ max Io Free air convection, (40-60LFM) -20 — +70* °C Thermal Resistance θja Free Air Convection, (40-60LFM) — 14 — °C/W Case Temperature Tc @ Thermal shutdown — — 100 °C Storage Temperature Ts -40 — 110 °C Mechanical Shock — Per Mil-STD-202F, Method 213B, 6mS, Half-sine, mounted to a PCB — 50 — G’s Mechanical Vibration — Per Mil-STD-202F, Method 204D, 10-500Hz, Soldered in a PCB — 10 — G’s Vo = 5V Vo = 12V Vo = 15V Weight — — — 28 — grams Isolation Capacitance Resistance — — — — — — 500 — 10 — 1100 — — — — V pF MΩ Flammability — Materials meet UL 94V-0 Remote On/Off On Off Open or 2.5 to 7.0 VDC above -Vin Short or 0 to 0.8 VDC above -Vin Ordering Information Through-Hole PT3104A = 5 Volts PT3105A = 12 Volts PT3106A = 15 Volts Surface Mount PT3104C = 5 Volts PT3105C = 12 Volts PT3106C = 15 Volts (For dimensions and PC board layout, see Package Style 700.) * See Thermal Derating Curves 62 Power Trends, Inc. 27715 Diehl Road, Warrenville, IL 60555 (800) 531-5782 Fax: (630) 393-6902 http://www.powertrends.com For assistance or to order, call (800) 531-5782 24V PT3100 Series CHARACTERISTIC DATA PT3106, 15.0 VDC (See Note 1) (See Note 1) Efficiency vs Output Current Efficiency vs Output Current 100 100 90 90 Efficiency vs Output Current 100 24V 70 32V 60 40V 80 18V 70 24V 32V 60 40V 50 50 0 0.5 1 1.5 2 2.5 0.5 0.75 Iout-(Amps) 24V 50 18V Ripple-(mV) 30 40V 70 32V 24V 50 18V 3 40V 70 18V 10 0.25 0.5 0.75 1 0.25 1.25 1 85˚C 0.75 0.5 0 85°C 0.6 0.4 0 0 24 26 28 30 32 34 36 38 40 18 20 22 Vin-(Volts) 24 26 28 30 32 34 36 38 18 40 4 3 32V 24V 2 PD-(Watts) 40V 40V 32V 2 24V Iout-(Amps) 2.5 3 32 34 36 0.25 38 40 Vin 40V 3 32V 24V 2 18V 1 0 2 30 18V 1 0 28 4 Vin 3 18V 1 26 5 4 Vin 1.5 24 Power Dissipation vs Output Current 5 1 22 Vin-(Volts) Power Dissipation vs Output Current 5 0.5 20 Vin-(Volts) Power Dissipation vs Output Current 0 70°C 0.2 0.25 0.5 (See Note 2) 0.8 Iout-(Amps) Iout-(Amps) 1.5 1 1 70˚C 1 85°C 2 0.75 Thermal Derating (Ta) (See Note 2) 1.25 70°C 22 0.5 Iout-(Amps) Thermal Derating (Ta) (See Note 2) 3 20 24V Iout-(Amps) Thermal Derating (Ta) 18 32V 50 30 Iout-(Amps) 2.5 Vin 90 Vin 10 2.5 1 110 30 10 0.75 Ripple vs Output Current PD-(Watts) Ripple-(mV) 32V 2 0.5 Iout-(Amps) 90 40V 1.5 40V 0.25 Ripple-(mV) Vin 70 1 32V 60 1.25 110 90 Iout-(Amps) 1 Ripple vs Output Current 110 0.5 24V Iout-(Amps) Ripple vs Output Current 0 18V 70 40 0.25 3 Vin 80 50 40 40 PD-(Watts) Efficiency - % 18V Efficiency - % Efficiency - % Vin 80 90 Vin 0 0.5 0.75 1 1.25 0.25 Iout-(Amps) 0.5 0.75 1 Iout-(Amps) Note 1: All data listed in the above graphs, except for derating data, has been developed from actual products tested at 25°C. This data is considered typical data for the DC-DC Converters. Note 2: Thermal derating graphs are developed in free air convection cooling of 40-60 LFM. Power Trends, Inc. 27715 Diehl Road, Warrenville, IL 60555 (800) 531-5782 Fax: (630) 393-6902 http:// www.powertrends.com 63 DATA SHEETS PT3105, 12.0 VDC (See Note 1) 24V Bus Products PT3104, 5.0 VDC IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1999, Texas Instruments Incorporated