PLL0210A 9939 Via Pasar • San Diego, CA 92126 TEL (858) 621-2700 FAX (858) 621-2722 PHASE LOCKED LOOP Rev A2 PHASE NOISE (1 Hz BW, typical) FEATURES • Frequency Range: 200 - 230 MHz • Step Size: 100 KHz • PLL - Style Package APPLICATIONS • Telecommunications • Satellite • Telemetry VALUE UNITS 200 - 230 MHz RMS Phase Error (100 Hz - 100 KHz) 0.5 Harmonic Suppression (2nd, typ.) -10 -65 ° dBc PERFORMANCE SPECIFICATIONS Frequency Range Sideband Spurs (typ.) Power Output dBc 3.5±2.5 dBm 50 Ω 100 KHz Load Impedance Step Size LOW Charge Pump Output Current Switching Speed (typ., adjacent channel) Startup Lock Time (typ.) Operating Temperature Range 1 mSec 5 -40 to +85 mSec °C PLL Package Style POWER SUPPLY REQUIREMENTS Supply Voltage (Vcc, nom.) Supply Current (Icc, typ.) 5 Vdc 25 mA All specifications are typical unless otherwise noted and subject to change without notice. APPLICATION NOTES • AN-107 : How to Solder Z-COMM VCOs / PLLs • AN-200 : Mounting and Grounding of Z-COMM PLLs • AN-201 : PLL Fundamentals AN-202 : PLL Functional Description NOTES: Reference Oscillator Signal: 5 MHz< f o s c <40 MHz © Z-Communications, Inc. Page 1 All rights reserved LOW COST - HIGH PERFORMANCE PHASE LOCKED LOOP PLL0210A PAGE 2 PLL OUTPUT SPECTRUM 0 -10 -20 POWER -30 -40 -50 -60 -70 -80 -90 -100 -5 -4 -3 -2 -1 210 MHz +1 +2 +3 +4 +5 FREQUENCY OFFSET (KHz) POWER CURVE, typ. 14 12 10 8 6 4 25 °c 2 0 -2 -4 200 204 208 212 216 220 224 228 232 236 240 PHYSICAL DIMENSIONS SIDE VIEW BOTTOM VIEW TOP VIEW © Z-Communications, Inc. Page 2 Printed in the U.S.A.