First Edition Approved by Production Div. Aug 9, 2000 LCD Module Specification Checked by Quality Assurance Div. Checked by Design Engineering Div. Prepared by Production Div. Final Revision ******** Type No. F-51167NCU-FW-AA Table of Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. General Specifications ............................................................................ 2 Electrical Specifications.......................................................................... 3 Optical Specifications ............................................................................. 8 I/O Terminal.......................................................................................... 10 Test......................................................................................................... 12 Appearance Standards........................................................................... 13 Code System of Production Lot ......................................................... 15 Type Number ........................................................................................ 15 Applying Precautions............................................................................ 15 Precautions Relating Product Handling .............................................. 16 Warranty................................................................................................. 17 Revision History Rev. Date F-51167NCU-FW-AA Page (AA) No.2000-0249 Comment OPTREX OPTREX CORPORATION Page 1/17 1.General Specif ications Operating Temp. : min. 0℃ ~ max. 50℃ Storage Temp. : min. -20℃ ~ max. 70℃ Dot Pixels : 320×3 [R.G.B] (W) × 240 (H) dots Dot Size : 0.10 (W) × 0.34 (H) mm Dot Pitch : 0.12 (W) × 0.36 (H) mm Viewing Area : 122.0 (W) × 92.0 (H) mm Outline Dimensions : 167.1* (W) × 109.0 (H) × 8.0 max. (D) mm * Without CFL Cable Weight : 204g max. LCD Type : CTD-17753 ( F-STN / Color-mode / Transmissive ) Viewing Angle : 12:00 Data Transfer : 8-bit parallel data transfer Duty : 1/240 Backlight : Cold Cathode Fluorescent Lamp (CFL) × 1 Drawings : Dimensional Outline F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX UE-300830 OPTREX CORPORATION Page 2/17 2.Electrical Specif ications 2.1.Absolute Maximum Ratings VSS=0V Parameter Supply Voltage Symbol Conditions Min. Max. Units VCC1-VSS - -0.3 7.0 V VCC2-VSS - 0 6.0 V VI - -0.3 VCC1+0.3 V VADJ-VSS - 0 3.0 V (Logic) Supply Voltage (LCD Drive) Input Voltage VADJ Input Voltage 2.2.DC Characteristics Ta=25℃, VSS=0V Parameter Supply Voltage Symbol Conditions Min. Typ. Max. Units VCC1-VSS - 3.0 - 5.5 V VCC2-VSS - 3.0 - 5.5 V VADJ-VSS - 0.8 - 2.7 V (Logic) Supply Voltage (LCD Drive) Voltage for Contrast Adjustment (Note1) High Level VIH VCC1=3.0~5.5V 0.8× VCC1 - VCC1 V VIL VCC1=3.0~5.5V 0 - 0.2× VCC1 V IVCC1 VCC1-VSS=5.0V - 20.0 40.0 mA IVCC2 VCC2-VSS=5.0V - 40.0 60.0 mA fCP VCC1=3.0~5.5V - - 30 MHz Input Voltage Low Level Input Voltage Supply Current (Note2) Clock Frequency Duty=50% Note1:The relation between Voltage for Contrast Adjustment and LCD Contrast is shown as follows; 0.8V(Bright)~2.7V(dark) Note2:Supply current which checker pattern displayed. fF=70Hz VOD=26.6 R G B R G B R G B R G B F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 3/17 2.3. AC Characteristics VCC1=3.0~5.5V Parameter Symbol LP Low Level Width Rise/Fall Time FLM Setup Time FLM Hold Time CP Cycle Time CP High Level Width CP Low Level Width LP Setup Time 1 LP Setup Time 2 LP Hold Time Data Setup Time Data Hold Time LP ↑ to CP ↑ LP ↓ to CP ↓ DISPOFF Low Level Width Max. Units tLP - 5 - ns tWLH tWLL tr, td tst thd tCP tWCH tWCL tst1 tst2 thd1 tst3 thd2 tLH tLS tWDL tSD - 40 - ns - 1000 - ns Note 1 - 6.6 ns - 60 - ns - 30 - ns - 40 - ns - 15 - ns - 15 - ns - 30 - ns - 30 - ns - 15 - ns - 15 - ns - 15 - ns - 25 - ns - 25 - ns - 100 - ns LP Cycle Time LP High Level Width Min. DISPOFF Cancellation Time 20 - - Note 1:The rise and fall times (tr, tf ) must satisfy the following relationships. tr, tf≦(1/f-2×tW)/2 tW:Minimum palse width f:frequency ns tLP tWLH tWLL tLH VIH LP VIL tst2 tWCH CP tst1 tLS tWCL thd1 tCP VIH VIL tst3 thd2 D0~D7 LAST DATA VIH VIL TOP DATA tST thd VIH FLM tWDL tSD DISPOFF VIH=0.7×VCC1 VIL=0.3×VCC1 F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 4/17 2.4.Timing Chart T=0.0595ms typ. LP CP D0 ~ SEG SEG SEG SEG D7 945~ 952 953~ 960 1~ 8 9~ 16 #1 DATA SEG SEG SEG SEG 945~ 952 953~ 960 1~ 8 9~ 16 FLM LP (Reduction) 240×T FLM (Reduction) 2.5.Comparison of Display and Data SEG1 #1 D7 SEG960 D6 D5 D4 D1 D0 TOP VIEW D0~D7 #240 F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 5/17 2.6.Power Supply ON/OFF Sequence 2.6.1.ON Sequence SIGNAL LEVEL VCC1,VCC2 VCC1,VCC2 VSS 0≦t VCC1 SIGNAL 50 ms≦t VSS VCC1 DISPOFF VSS 2.6.2.OFF Sequence LEVEL SIGNAL VCC1,VCC2 VSS 0≦t VCC1,VCC2 VCC1 VSS SIGNAL 200 ms≦t VCC1 VSS DISPOFF Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module. F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 6/17 2.7.Lighting Specifications Ta=25℃ Parameter Symbol Conditions Min. Typ. Max. Units Notes Lamp Voltage VL - - 430 - Vrms 1 Lamp Current IL - 4.0 5.0 6.0 mArms 2 Starting Voltage VS - - - 700 Vrms 3 Surface Luminance L IL = 5.0 mA 100 120 - cd/㎡ 4 Average Life TAL IL = 5.0 mA 20000 hrs 5 - - Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for 3 minutes . Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after lighting for 3 minutes. Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V. Note 4 : Surface Luminance is specified by the average of 9 luminance values measured at each point shown above after 20 minutes power on with the all ON pattern adjusted to maximum contrast and the dimming control of 100%. ( maximum brightness ) Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the luminance value. Average Life representes the time elapsed at the point of time when the residual ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life mentioned above. Y=60 I N C VS VL V Y=160 Y=260 P1 P2 P3 P4 P5 P6 P7 P8 P9 F L X=60 X=120 X=180 IL Measurement Points CFL Testing Circuit F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 7/17 3.Optical Specif ications 3.1.Optical Characteristics Ta=25℃, 1/240 Duty,1/16.2 Bias, VOD=26.6V, θ= 0 ゚, φ=-゚ Parameter Contrast Ratio Symbol Conditions Min. Typ. Max. CR θ= 0 ゚, φ=-゚ - 40 - x - - 0.324 - y - - 0.361 - Note 1 Chromaticity (white) Viewing Angle Response Units Shown in 3.3 Rise Note 2 TON - - 400 600 ms Time Decay Note 3 TOFF 150 230 ms - - Note 1 : Contrast ratio is definded as follows. CR = LON / LOFF LON : Luminance of the ON segments LOFF : Luminance of the OFF segments Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 : Definition of Driving Voltage VOD Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its maximum. VO-P ( B-2 )×VO-P / B 1 / ( f F× A ) 1 / fF 〈ON SIGNAL〉 F-51167NCU-FW-AA (AA) No.2000-0249 〈OFF SIGNAL〉 OPTREX OPTREX CORPORATION Page 8/17 3.2.Definition of Viewing Angle and Optimum Viewing Area ・Point ● shows the point where contrast ratio is measured. : θ= 0 ゚, φ=-゚ ・Driving condition : 1/240 Duty,1/16.2 Bias, VOD= 26.6V, fF=70Hz 90 ゚ 45 ゚ 135 ゚ θ φ 180 ゚ 10 20 30 40 50 90 ゚ (φ= 0 ゚) θ φ 180 ゚ 225 ゚ 0゚ 315 ゚ 270 ゚ 270 ゚ ・Area shows typ. CR≧2 3.3.System Block Diagram Temperature Chamber Rotation Table (θ,φ) Photometer #1980A WB LCD φ Optical Fiber θ Control Unit & Computer Waveform Generator Halogen bulb F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 9/17 4.I/O Terminal 4.1.Pin Assignment CN1 No. Symbol Level Function 1 D0 H/L Display Data 2 D1 H/L Display Data 3 D2 H/L Display Data 4 D3 H/L Display Data 5 D4 H/L Display Data 6 D5 H/L Display Data 7 D6 H/L Display Data 8 D7 H/L Display Data 9 DISP OFF H/L Display Control Signal 10 FLM H/L First Line Marker 11 LP H→L Data Latch Signal 12 CP H→L Clock Signal for Shifting Data 13 M H/L Alternate Signal for LCD Drive 14 VCC1 - Power Supply for Logic 15 VSS ― Power Supply (0V, VSS) 16 VSS ― Power Supply (0V, VSS) 17 VCC2 - Power Supply for LCD Drive 18 CN2 VADJ ― Voltage Level for LCD Contrast Adjustment No. Symbol Level 1 CFL HOT - Power Supply for CFL (HOT) 2 NC - Non-connection 3 NC - Non-connection 4 CFL GND - Power Supply for CFL (GND) H : Display on L : Display off Function 4.2.Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. 3.3V R1 VR VADJ MODULE R2 VSS VSS VCC1 VCC1 VCC2 VCC2 R1+R2+VR=10~20KΩ F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 10/17 4.3.Block Diagram 8 D0~D7 SEG.DRIVER MN863830 × 4 or equivalent CP 2 LP DISPOFF 2 960 M M CIRCUIT COM.DRIVER MN86372 × 2 or equivalent FLM 240 L C D P 320×3[RGB]×240dots TO LSI LOGIC VCC1 VCC2 VADJ Bias circuit TO LSI VSS CFL CFL HOT CFL GND F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 11/17 5.Test No change on display and in operation under the following test condition. No. Parameter Conditions Notes 1 High Temperature Operating 50℃±2℃, 96hrs (operation state) 2 Low Temperature Operating 0℃±2℃, 96hrs (operation state) 3 3 High Temperature Storage 60℃±2℃, 96hrs 4 4 Low Temperature Storage -20℃±2℃, 96hrs 3, 4 5 Damp Proof Test 40℃±2℃, 90~95%RH, 96hrs 3, 4 6 Vibration Test Total fixed amplitude : 1.5mm 5 Vibration Frequency : 10~55Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state. F E G B D C A 60cm Concrete Surface Dropping method corner dropping A corner : once Edge dropping B,C,D edge : once Face dropping E,F,G face : once Note 1 : Unless otherwise specified, tests will be conducted under the following condition. Temperature : 20±5℃ Humidity : 65±5% Note 2 : Unless otherwise specified, tests will be not conducted under functioning state. Note 3 : No dew condensation to be observed. Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 5 : Vibration test will be conducted to the product itself without putting it in a container. F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 12/17 6.Appearance Standards 6.1.Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45 ゚ against perpendicular line. 45゚ 6.2.Definition of applicable Zones A Zone Bezel Flame B Zone C Zone A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 13/17 6.3.Standards No. 1 Parameter Black and Criteria (1) Round Shape White Spots, Foreign Substances Zone Acceptable Number Dimension (mm) A B C D ≦0.1 * * * 0.1 < D ≦0.2 3 5 * 0.2 < D ≦0.25 2 3 * 0.25< D ≦0.3 0 1 * 0.3 < D 0 0 * D = ( Long + Short ) / 2 * : Disregard (2) Line Shape Zone X (mm) Acceptable Number Y (mm) A B C - 0.03≧W * * * 2.0≧L 0.05≧W 3 3 * 1.0≧L 0.1 ≧W 3 3 * - 0.1 <W X : Length Y : Width In the same way (1) * : Disregard Total defects shall not exceed 5. 2 Air Bubbles (between glass & polarizer) Zone Dimension (mm) Acceptable Number A B C D ≦ 0.3 * * * 0.3 < D ≦ 0.4 3 * * 0.4 < D ≦ 0.6 2 3 * 0.6 < D 0 0 * * : Disregard Total defects shall not exceed 3. 3 The Shape of Dot However, each pixel shall remain more than one-third of the original pixel size. 4 Polarizer Scratches Not to be conspicuous defects. 5 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not defective. 6 7 Complex Foreign Black spots, line shaped foreign substances or air bubbles between Substance Defects glass & polarizer should be 5pcs maximum in total. Distance between D≦0.2 : 20mm or more Different Foreign 0.2<D : 40mm or more Substance Defects F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 14/17 7.Code System of Production Lot The production lot of module is specified as follows. □ □ □ □ □ □ Factory Number (Numeral) Factory Code (Alphabet) Production Week (1~5) Production Month (1~9, X, Y, Z) Production Year (Lower 2 digits) 8.Type Number The type number of module is specified on the back of module as follows. F-51167NCU-FW-AA Label 9.Applying Precautions Please contact us when questions and/or new problems not specified in this specifications arise. F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 15/17 10. Precautions Relating Product Handling The Following precautions will guide you in handling our product correctly. 1) Liquid crystal display devices ① The liquid crystal display device panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care. The polarizer adhering to the surface of the LCD is made of a soft material. ② Guard against scratching it. 2) Care of the liquid crystal display module against static electricity discharge. ① When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. ② Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. ③ Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity. 3) When the LCD module alone must be stored for long periods of time: ① Protect the modules from high temperature and humidity. ② Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. ③ Protect the modules from excessive external forces. 4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature. 5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity. 7) For models which use CFL: ① High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. ② Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. ③The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 16/17 8) For models which use touch panels: ①Do not stack up modules since they can be damaged by components on neighboring modules. ②Do not place heavy objects on top of the product. This could cause glass breakage. 9) For models which use COG,TAB,or COF: ①The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. ②Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact. 10) Models which use flexible cable, heat seal, or TAB: ①In order to maintain reliability, do not touch or hold by the connector area. ②Avoid any bending, pulling, or other excessive force, which can result in broken connections. 11. Warranty This product has been manufactured to your company’s specifications as a part for use in your company’s general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. ① We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. ② We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. ③ We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company’s acceptance inspection procedures. ④ When the product is in CFL models, CFL service life and brightness will vary according to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. ⑤ We cannot accept responsibility for industrial property, which may arise through the use of your product, with exception to those issues relating directly to the structure or method of manufacturing of our product. ⑥ Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later. F-51167NCU-FW-AA (AA) No.2000-0249 OPTREX OPTREX CORPORATION Page 17/17