SANKEN FMG-36R

Ultra-Fast-Recovery Rectifier Diodes
Absolute Maximum Ratings
Parameter
I F (AV) (A)
VRM
(V)
Type No.
FMG-32S/R
200
FMG-33S/R
300
IFSM
(A)
Tj
(°C)
Tstg
(°C)
50Hz
With
Sinewave
Heatsink Half-cycle
Single Shot
max per
element
150
20.0
VF
(V)
IR
(mA)
IF
(A)
VR = VRM
Electrical Characteristics (Ta = 25°C)
t rr ➀
t rr ➁
IR (H)
(ns)
(ns)
(mA)
VR=VRM, Ta=100°C
max per element max per element
IF /IRP
(mA)
Others
Rth ( j-c)
Mass
IF /IRP
(mA)
(°C/ W)
(g)
100/200
2.0
5.5
Fig.
1.80
10.0
–40 to +150
1.0
FMG-34S/R
400
16.0
100
2.00
FMG-36S/R
600
15.0
80
2.20
5.0
100 100/100
50
A
7.5
FMG-32S/R, 33S/R
t /T = 1/6
12
t /T= 1/ 3, Sinewave
8
4
0
50
70
90
110
130
Case Temperature Tc (°C)
1
Ta = 150ºC
100ºC
60ºC
25ºC
0.1
0.01
0.001
150
Peak Forward Surge Current
D.C.
0
2.0
0.4
0.8
1.2
1.6
Forward Voltage VF (V)
120
20ms
90
60
30
0
2.4
I FSM (A)
I FSM (A)
150
10
16
I FMS Rating
50
t /T = 1/2
Forward Current IF (A)
Average Forward Current I F (AV) (A)
VF —IF Characteristics (Typical)
Tc—IF(AV) Derating
20
1
5
10
Overcurrent Cycles
50
FMG-34S/R
t /T = 1/6
t /T= 1/ 3, Sinewave
8
4
70
90
110
130
Case Temperature Tc (°C)
1
Ta = 130ºC
100ºC
60ºC
28ºC
0.1
0.01
0.001
150
Peak Forward Surge Current
0
2.0
0.4
0.8
1.2
1.6
Forward Voltage VF (V)
80
20ms
60
40
20
0
2.4
I FSM (A)
10
D.C.
0
50
100
I FSM (A)
t /T = 1/2
12
I FMS Rating
30
Forward Current IF (A)
Average Forward Current I F (AV) (A)
VF —IF Characteristics (Typical)
Tc—IF(AV) Derating
16
1
5
10
Overcurrent Cycles
50
FMG-36S/R
20
10
D.C.
t /T = 1/6
9
t /T= 1/ 3, Sinewave
6
3
0
50
70
90
110
130
Case Temperature Tc (°C)
External Dimensions
Fig. A
0.1
0.01
0.8 2.8 5.0
3.5
20.0
0
2.0
0.4
0.8
1.2
1.6
Forward Voltage VF (V)
2.4
I FSM (A)
20ms
60
50
40
30
20
10
0
1
5
10
Overcurrent Cycles
50
3.3
2.3
3.4
1.0
16.5 ±0.5
20.0 ±0.5
Ta = 150ºC
100ºC
25ºC
70
5.0
15.0
9.0
(Unit: mm) (Full-mold)
Flammability:
UL94V-0 or Equivalent
150
I FSM (A)
1
0.001
I FMS Rating
80
Peak Forward Surge Current
t /T = 1/2
12
Forward Current IF (A)
Average Forward Current I F (AV) (A)
VF —IF Characteristics (Typical)
Tc—IF(AV) Derating
15
+0.2
0.65 –0.1
S type
5.45
5.45
R type
2.6
57