VER : A_4 update : 2012.05.14 AC-DC Power Module AQC100 SERIES 100 Watts KEY FEATURES Switching Power Module for PCB Mountable High Efficiency up to 93% Typical Active PFC Function, >0.95 (230Vac), >0.99 (115Vac) Universal Input: 90-264 VAC Low Leakage Current, <250uA Four M3 Mounting Holes Optional on Bottom Side Remote ON/OFF Control EN55022 Class B Meets Class I and Class II Construction Continuous Short Circuit Protection with Hiccup Mode and Auto Recover 3-Years Product Warranty ELECTRICAL SPECIFICATIONS Model No. AQC100-12S AQC100-15S AQC100-24S AQC100-48S Max Output Wattage (W) Voltage 85 W 85W 100W 100W 90-264 VAC or 120-370 VDC Frequency (Hz) Input Output Protection Isolation Current (Full load) <2.0 A max. (115 VAC) / <1.0 A max. (230 VAC) Inrush Current (<2ms) < 30 A max. (115 VAC) / < 60 A max. (230 VAC) Leakage Current < 0.5 mA max. Power Factor PF>0.99 (115 VAC) / PF>0.95 (230 VAC) at Full Load Voltage (V.DC.) 12V Voltage Accuracy ±2% 15V 24V 48V 5.66 4.2 2.1 Current (A) max 7.08 Line Regulation ±1% Load Regulation ±1% Minimum Load 0% Maximum Capacitive Load 70,000µF 50,000µF 6,000µF 1,000µF Ripple & Noise max. 120mV 150mV 200mV 240mV Efficiency (typ.) 90% 90% 92% 93% Hold-up Time 10 ms (110 VAC) min. Switching Frequency 100~133 kHz Over Power Protection Auto recovery Over Voltage Protection Zener diode clamp Short Circuit Protection Auto recovery, Hiccup mode Input-Output (V.AC) 3000V Input-FG (V.AC) 1500V Output-FG .(V.AC) Operating Temperature Environment 47-63 Hz 500V -25°C…+70°C (with derating) Storage Temperature -25°C…+85°C Temperature Coefficient ±0.03%/°C ( 0~50°C ) Humidity 95% RH MTBF >250,000 h @ 25°C (MIL-HDBK-217F, Notice 1) Vibration 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes. Dimension (L x W x H) 4.3 x 2.3 x 1.18 Inches Weight 310 g Cooling Method Free convection Safety Agency Approvals EMI CE, UL60950-1 EMC (Conducted & Radiated Emission) Physical EMS (Noise Immunity) ( 109.0 x 58.5 x 30.0 mm ) Tolerance ±0.1 mm EN61000-6-3、EN 55022 class B (Conductive plane to be connected to safety earth) EN 55024、EN61000-4-2,3,4,5,6,8,11 1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. 2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 3.Hold-up Time measured at 90% Vout. -1- VER : A_4 update : 2012.05.14 AC-DC Power Module AQC100 SERIES 100 Watts MECHANICAL DIMENSION ( Top View ) PIN# Φ SINGLE 1 1.2±0.1%mm AC IN (N) 2 1.2±0.1%mm AC IN (L) 3 1.2±0.1%mm FG 4 1.2±0.1%mm ON / OFF (Provide +5Vdc Controlled External) 5 1.8±0.1%mm +DC OUT 6 1.8±0.1%mm -DC OUT 7 1.2±0.1%mm Trim Remark: Please reserve the pin 4 hole on PCB. If the remote on/off function is not required, please connect the pin 4 circuit layout with pin6, or keep pin 4 floating. DERATING BLOCK DIAGRAM EFFICIENCY VERSUS LOAD http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : A_4 update : 2012.05.14 AC-DC Power Module AQC100 SERIES 100 Watts AQC100-12S VIN Input Voltage (V) Efficiency (%) VS Efficiency Efficiency 115 180 230 264 Load (%) 10 20 30 40 50 87.87 89.51 90.67 90.88 90.96 115V (%) 78.62 85.67 88.07 89.14 89.76 230V (%) 73.49 83.84 86.57 88.55 89.76 Load (%) 60 70 80 90 100 115V (%) 89.95 90.00 90.02 89.77 89.51 230V (%) 90.22 90.58 90.83 90.85 90.88 80% 100% 100.00% 95.00% 95.00% 90.00% 90.00% 85.00% EFF% 85.00% EFF% VS 90 100.00% 80.00% 75.00% 80.00% 75.00% 70.00% 70.00% 65.00% 65.00% 60.00% 60.00% 90V LOAD 55.00% 115V 180V 230V 264V 10% 20% 30% 40% 50% VIN 60% 70% 90% LOAD AQC100-15S VIN Input Voltage (V) Efficiency (%) VS Efficiency Efficiency 115 180 230 264 Load (%) 10 20 30 40 50 88.41 90.17 91.11 91.59 91.53 115V (%) 74.53 83.09 86.59 88.41 89.20 230V (%) 73.94 82.70 85.31 87.77 89.14 Load (%) 60 70 80 90 100 115V (%) 89.70 89.93 89.99 90.11 90.17 230V (%) 89.97 90.63 90.91 91.15 91.59 80% 100% 100.00% 95.00% 95.00% 90.00% 90.00% 85.00% EFF% 85.00% EFF% VS 90 100.00% 80.00% 75.00% 80.00% 75.00% 70.00% 70.00% 65.00% 65.00% 60.00% 60.00% 90V LOAD 55.00% 115V 180V VIN http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 230V 264V 10% 20% 30% 40% 50% 60% 70% 90% LOAD -3- VER : A_4 update : 2012.05.14 AC-DC Power Module AQC100 SERIES 100 Watts EFFICIENCY VERSUS LOAD AQC100-24S VIN Input Voltage (V) Efficiency (%) VS Efficiency Efficiency 115 180 230 264 Load (%) 10 20 30 40 50 90.45 92.45 93.62 93.35 93.26 115V (%) 80.71 87.31 90.00 91.22 92.10 230V (%) 73.64 84.39 88.42 90.56 91.76 Load (%) 60 70 80 90 100 115V (%) 92.41 92.51 92.53 92.47 92.45 230V (%) 92.54 92.97 93.28 93.52 93.35 80% 100% 100.00% 95.00% 95.00% 90.00% 90.00% 85.00% EFF% 85.00% EFF% VS 90 100.00% 80.00% 75.00% 80.00% 75.00% 70.00% 70.00% 65.00% 65.00% 60.00% 60.00% 90V LOAD 55.00% 115V 180V 230V 264V 10% 20% 30% 40% 50% VIN 60% 70% 90% LOAD AQC100-48S VIN Input Voltage (V) Efficiency (%) VS Efficiency Efficiency 115 180 230 264 Load (%) 10 20 30 40 50 91.22 93.13 94.24 94.59 94.66 115V (%) 82.39 88.10 90.73 91.67 92.58 230V (%) 71.87 83.73 89.12 91.05 92.41 Load (%) 60 70 80 90 100 115V (%) 92.92 93.02 93.11 93.16% 93.13 230V (%) 93.18 93.63 93.95 94.32 94.59 80% 100% 100.00% 95.00% 95.00% 90.00% 90.00% 85.00% EFF% 85.00% EFF% VS 90 100.00% 80.00% 75.00% 80.00% 75.00% 70.00% 70.00% 65.00% 65.00% 60.00% 60.00% 90V LOAD 55.00% 115V 180V VIN http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 230V 264V 10% 20% 30% 40% 50% 60% 70% 90% LOAD -4-