ARCH AQC100-15S

VER : A_4
update : 2012.05.14
AC-DC Power Module
AQC100
SERIES
100 Watts
KEY FEATURES
„
„
„
„
„
„
„
„
„
„
Switching Power Module for PCB Mountable
High Efficiency up to 93% Typical
Active PFC Function, >0.95 (230Vac), >0.99 (115Vac)
Universal Input: 90-264 VAC
Low Leakage Current, <250uA
Four M3 Mounting Holes Optional on Bottom Side
Remote ON/OFF Control
EN55022 Class B Meets
Class I and Class II Construction
Continuous Short Circuit Protection with Hiccup Mode
and Auto Recover
„ 3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Model No.
AQC100-12S
AQC100-15S
AQC100-24S
AQC100-48S
Max Output Wattage (W)
Voltage
85 W
85W
100W
100W
90-264 VAC or 120-370 VDC
Frequency (Hz)
Input
Output
Protection
Isolation
Current (Full load)
<2.0 A max. (115 VAC) / <1.0 A max. (230 VAC)
Inrush Current (<2ms)
< 30 A max. (115 VAC) / < 60 A max. (230 VAC)
Leakage Current
< 0.5 mA max.
Power Factor
PF>0.99 (115 VAC) / PF>0.95 (230 VAC) at Full Load
Voltage (V.DC.)
12V
Voltage Accuracy
±2%
15V
24V
48V
5.66
4.2
2.1
Current (A) max
7.08
Line Regulation
±1%
Load Regulation
±1%
Minimum Load
0%
Maximum Capacitive Load
70,000µF
50,000µF
6,000µF
1,000µF
Ripple & Noise max.
120mV
150mV
200mV
240mV
Efficiency (typ.)
90%
90%
92%
93%
Hold-up Time
10 ms (110 VAC) min.
Switching Frequency
100~133 kHz
Over Power Protection
Auto recovery
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Auto recovery, Hiccup mode
Input-Output (V.AC)
3000V
Input-FG
(V.AC)
1500V
Output-FG
.(V.AC)
Operating Temperature
Environment
47-63 Hz
500V
-25°C…+70°C (with derating)
Storage Temperature
-25°C…+85°C
Temperature Coefficient
±0.03%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>250,000 h @ 25°C (MIL-HDBK-217F, Notice 1)
Vibration
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
Dimension (L x W x H)
4.3 x 2.3 x 1.18 Inches
Weight
310 g
Cooling Method
Free convection
Safety
Agency Approvals
EMI
CE, UL60950-1
EMC
(Conducted & Radiated Emission)
Physical
EMS (Noise Immunity)
( 109.0 x 58.5 x 30.0 mm ) Tolerance ±0.1 mm
EN61000-6-3、EN 55022 class B (Conductive plane to be connected to safety earth)
EN 55024、EN61000-4-2,3,4,5,6,8,11
1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
3.Hold-up Time measured at 90% Vout.
-1-
VER : A_4
update : 2012.05.14
AC-DC Power Module
AQC100
SERIES
100 Watts
MECHANICAL DIMENSION ( Top View )
PIN#
Φ
SINGLE
1
1.2±0.1%mm
AC IN (N)
2
1.2±0.1%mm
AC IN (L)
3
1.2±0.1%mm
FG
4
1.2±0.1%mm
ON / OFF
(Provide +5Vdc Controlled External)
5
1.8±0.1%mm
+DC OUT
6
1.8±0.1%mm
-DC OUT
7
1.2±0.1%mm
Trim
Remark:
Please reserve the pin 4 hole on PCB.
If the remote on/off function is not required, please
connect the pin 4 circuit layout with pin6, or keep pin
4 floating.
DERATING
BLOCK DIAGRAM
EFFICIENCY VERSUS LOAD
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_4
update : 2012.05.14
AC-DC Power Module
AQC100
SERIES
100 Watts
AQC100-12S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
Efficiency
115
180
230
264
Load (%)
10
20
30
40
50
87.87
89.51
90.67
90.88
90.96
115V (%)
78.62
85.67
88.07
89.14
89.76
230V (%)
73.49
83.84
86.57
88.55
89.76
Load (%)
60
70
80
90
100
115V (%)
89.95
90.00
90.02
89.77
89.51
230V (%)
90.22
90.58
90.83
90.85
90.88
80%
100%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
VS
90
100.00%
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
90V
LOAD
55.00%
115V
180V
230V
264V
10%
20%
30%
40%
50%
VIN
60%
70%
90%
LOAD
AQC100-15S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
Efficiency
115
180
230
264
Load (%)
10
20
30
40
50
88.41
90.17
91.11
91.59
91.53
115V (%)
74.53
83.09
86.59
88.41
89.20
230V (%)
73.94
82.70
85.31
87.77
89.14
Load (%)
60
70
80
90
100
115V (%)
89.70
89.93
89.99
90.11
90.17
230V (%)
89.97
90.63
90.91
91.15
91.59
80%
100%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
VS
90
100.00%
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
90V
LOAD
55.00%
115V
180V
VIN
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
230V
264V
10%
20%
30%
40%
50%
60%
70%
90%
LOAD
-3-
VER : A_4
update : 2012.05.14
AC-DC Power Module
AQC100
SERIES
100 Watts
EFFICIENCY VERSUS LOAD
AQC100-24S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
Efficiency
115
180
230
264
Load (%)
10
20
30
40
50
90.45
92.45
93.62
93.35
93.26
115V (%)
80.71
87.31
90.00
91.22
92.10
230V (%)
73.64
84.39
88.42
90.56
91.76
Load (%)
60
70
80
90
100
115V (%)
92.41
92.51
92.53
92.47
92.45
230V (%)
92.54
92.97
93.28
93.52
93.35
80%
100%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
VS
90
100.00%
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
90V
LOAD
55.00%
115V
180V
230V
264V
10%
20%
30%
40%
50%
VIN
60%
70%
90%
LOAD
AQC100-48S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
Efficiency
115
180
230
264
Load (%)
10
20
30
40
50
91.22
93.13
94.24
94.59
94.66
115V (%)
82.39
88.10
90.73
91.67
92.58
230V (%)
71.87
83.73
89.12
91.05
92.41
Load (%)
60
70
80
90
100
115V (%)
92.92
93.02
93.11
93.16%
93.13
230V (%)
93.18
93.63
93.95
94.32
94.59
80%
100%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
VS
90
100.00%
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
90V
LOAD
55.00%
115V
180V
VIN
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
230V
264V
10%
20%
30%
40%
50%
60%
70%
90%
LOAD
-4-