Features

Isolated

Output Over-Voltage Shutdown

High Efficiency

OCP/SCP

High Power Density

Over Temperature Protection

Fixed Frequency (258 kHz)

Low Cost

Input Under-Voltage Lockout

Output Voltage Trim

Input Over-Voltage Lockout

Positive/Negative Remote Sense

Ultra Wide Input Range:
18 Vdc - 75 Vdc

Basic Insulation

Remote On/Off

UL60950-1 Recognized (UL/cUL) (Pending)
Applications

Networking

Computers and peripherals

Telecommunications
Description
The 0RCY-60U12x is part of the isolated dc/dc converters that operate from a wide input range (18 Vdc - 75 Vdc)
and can cover both 24 Vin and 48 Vin input range. These units will provide up to 84 W of output power. They are
designed to be highly efficient and low cost. Features include remote on/off, over current protection, over voltage
shut down, over temperature protection and under-voltage lockout. These converters are provided in an industry
standard 1/8 brick package.
Part Selection
Output
Voltage
Input
Voltage
12 Vdc
18 Vdc 75 Vdc
Max.
Output
Current
Max.
Output
Power
Typical
Efficiency
Model Number
Active High
With Heatsink
Model Number
Active Low
With Heatsink
Model Number
Active Low
Without Heatsink
7A
84 W
92%
0RCY-60U120
0RCY-60U12L
0RCY-60U12B
Notes: Add “G” suffix at the end of the model number to indicate Tray Packaging.
Part Number Explanation
0 R CY – 60 U 12 x
1 2
3
4
5 6
7
1---Through hole
2---RoHS 6, change “R” to “7” means RoHS 5
3---Series name
4---Series code
5---Input range (18-75V)
6---Output voltage 12V
7---Option, “x” of the model part number to be 0-9, A-Z, which will represent the special request of
customer.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
1
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Apr. 28, 2011
Absolute Maximum Ratings
Parameter
Input Voltage (continuous)
Input Transient Voltage
Remote On/Off
I/O Isolation Voltage
Min
Typ
Max
Unit
-0.3
-
80
V
-
-
100
V
-0.3
-
18
V
-
-
1500
V
Ambient Temperature
-40
-
85
C
Storage Temperature
-55
-
125
C
Notes
100 mS maximum
Note: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may
permanently damage the device.
Input Specifications
Parameter
Input Voltage
Min
18
Typ
24/48
Max
75
Unit
V
-
6.7
1.6
-
A
A
Input Current (no load)
-
100
180
mA
Remote Off Input Current
-
10
15
mA
Input Reflected Ripple Current
(rms)
-
7
10
mA
Input Reflected Ripple Current
(pk-pk)
-
15
30
mA
I t Inrush Current Transient
-
0.05
0.1
As
Turn-on Voltage Threshold
16.0
17.0
17.5
V
Turn-off Voltage Threshold
15.0
16.0
16.5
V
Input Over Voltage Lockout
76
78
80
V
Notes
Input Current (full load)
Vin=18 V
Vin=75 V
2
Tested with simulated source
impedance of 10 uH, 5 Hz to 20 MHz;
use a 1 uF/100 V ceramic cap and a
100 uF/100 V electrolytic cap with
ESR = 1 ohm max. at 200 kHz at
25 C.
2
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
Recommend a fast-acting fuse with maximum rating of 8A on system board. Refer to the fuse
manufacture’s datasheet for further information.
Notes: 1. This converter has internal C-L-C (2.2uH-2*0.47uF+2.2uF) filter.
2. All specifications are typical at 25 C unless otherwise stated.
Output Specifications
Parameter
Output Voltage Set Point
Min
11.76
Typ
12.00
Max
12.24
Unit
V
Load Regulation
-
±6
±12
mV
Line Regulation
-
±10
±20
mV
Regulation Over Temperature
(-40deg.C~ +85deg.C)
-
±30
±50
mV
Ripple and Noise (rms)
-
25
50
mV
Ripple and Noise (pk-pk)
-
100
150
mV
Notes
Vin=48 V, Io=50% load
0-20 MHz BW, with a 0.1 µF ceramic
cap and a 10 uF tantalum cap at the
output.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
2
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Apr. 28, 2011
Output Specifications (continued)
Parameter
Output Current Range
Output DC Current Limit
Min
Typ
Max
Unit
0
-
7
A
7.7
-
11
A
2
Notes
Vin=48 V, in Hiccup Mode.
Short Circuit Surge Transient
-
3
5
As
Rise Time
5
10
15
mS
-
20
25
mS
Ton(Enable from Vin)
-
20
25
mS
Ton(Enable from ON/OFF)
Overshoot at Turn on
-
0
3
%
Output Capacitance
0
-
1000
uF
Overshoot
-
300
400
mV
Settling Time
-
400
600
uS
Overshoot
-
300
400
mV
Settling Time
-
400
600
uS
Turn on Time
Transient Response
75% ~ 50%
Max Load
50% ~ 75%
Max Load
di/dt=0.1 A/us, Vin=24 Vdc, Ta=25 °C,
with a 0.1 µF ceramic cap and a 10 uF
tantalum cap at output.
Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
General Specifications
Parameter
Min
Typ
Max
Unit
Notes
90
90.5
91.5
92
-
%
%
Switching Frequency
240
258
280
kHz
Isolation Capacitance
-
1500
-
pF
Remote Sense Compensation
-
-
10
%
80
-
110
%
Over Temperature Protection
-
125
-
C
Over Voltage Protection
-
-
13.8
V
Vin=48 V, full load, in Hiccup mode.
1,867,232
hours
Calculated Per Bell Core SR-332
(Vo=12V, Io=80%load, Ta = 25 C)
2.30 x 0.896 x 0.49
58.42 x 22.76 x 12.47
-
0RCY-60U120 & 0RCY-60U12L
2.30 x 0.900 x 0.45
58.42 x 22.86 x 11.50
-
0RCY-60U12B
g
0RCY-60U120 & 0RCY-60U12L
Efficiency
Vin=24 V
Vin=48 V
Output Voltage Trim Range
MTBF
Measured at normal Vin, full load.
The total voltage increased by trim
and remote sense should not exceed
15%Vo.
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Weight
-
31.2
-
Note: All specifications are typical at 25 C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
3
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Apr. 28, 2011
Remote On/Off
Parameter
Signal Low (Unit On)
Signal High (Unit Off)
Signal Low (Unit Off)
Signal High (Unit On)
Active Low
Active High
Min
-0.3
Typ
-
Max
0.8
Unit
V
2.4
-
18
V
-0.3
-
0.8
V
2.4
-
18
V
0
-
0.75
mA
Current Sink
Notes
0RCY-60U12L & 0RCY-60U12B.
The remote on/off pin open, Unit off.
0RCY-60U120.
The remote on/off pin open, Unit on.
Output Trim Equations
Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected
between the Trim pin and GND pin. The Trim Up resistor should be connected between the Trim pin and the
Vout pin. Only one of the resistors should be used for any given application.
Rtrimdown 
511
 10.22k
delta
Vout
Module
(100  delta)  Vo  5.11  626
Rtrimup 
 10.22k 
1 .225  delta
Note:
Trim
GND
Rtrimdown
Vout
Vo _ req  Vo   100 % 
delta 
Module
Vo
Trim
Rtrimup
GND
Vo_req=Desired (trimmed) output voltage [V]
Output voltage Vo=12.00 V
Efficiency Data
Efficiency Curve
Efficiency
90.00%
80.00%
18 V
70.00%
24 V
48 V
75 V
60.00%
50.00%
0.7A
1.75A
3.5A
5.25A
7A
Output Current (A)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
4
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Apr. 28, 2011
Thermal Derating Curves
Maximum FET junction temperature derated to 120 C
0RCY-60U120 & 0RCY-60U12L
Vin=24 V, Vo=12 V
Vin=48 V, Vo=12 V
0RCY-60U12B
Vin=24 V, Vo=12 V
Vin=48 V, Vo=12 V
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
5
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Apr. 28, 2011
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Ripple and Noise Waveforms
24 Vdc input, 12 Vdc/7 A output
48 Vdc input, 12 Vdc/7 A output
Note: Ripple and noise at full load, 0-20 MHz BW, with a 0.1 uF ceramic cap and a 10 uF tantalum cap at the
output, and Ta=25 deg C.
Transient Response Waveforms
50%-75% Load Transients at Vin=24 V
75%-50% Load Transients at Vin=48 V
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
6
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Apr. 28, 2011
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Transient Response Waveforms (continued)
50%-75% Load Transients at Vin=24 V
75%-50% Load Transients at Vin=48 V
Note: Transients Response at Vo=12V, di/dt=0.1 A/us, with a 0.1 µF ceramic cap and a 10 uF tantalum cap at
output, and Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
7
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Apr. 28, 2011
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Mechanical Outline
0RCY-60U120 & 0RCY-60U12L
Pin Connections
Pin
Name
Function
Pin Dia
1
Vin+
0.040’’
2
On/Off
3
4
5
6
7
8
VinVoutSenseTrim
Sense+
Vout+
Positive input voltage
Input to turn converter
on and off, referenced
to VinNegative input voltage
Negative output voltage
Negative remote sense
Output voltage trim
Positive output voltage
Positive output voltage
0.040’’
0.040’’
0.062’’
0.040’’
0.040’’
0.040’’
0.062’’
Notes: 1. Pin 5 must be connected to Vout-.
2. Leave Pin 6 open for nominal voltage.
3. Pin 7 must be connected to Vout+.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
8
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Apr. 28, 2011
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Mechanical Outline (continued)
0RCY-60U12B
Pin Connections
Pin
Name
Function
Pin Dia
1
Vin+
0.040’’
2
On/Off
3
4
5
6
7
8
VinVoutSenseTrim
Sense+
Vout+
Positive input voltage
Input to turn converter
on and off, referenced
to VinNegative input voltage
Negative output voltage
Negative remote sense
Output voltage trim
Positive output voltage
Positive output voltage
0.040’’
0.040’’
0.062’’
0.040’’
0.040’’
0.040’’
0.062’’
Notes: 1. Pin 5 must be connected to Vout-.
2. Leave Pin 6 open for nominal voltage.
3. Pin 7 must be connected to Vout+.
Note: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered
using a peak solder temperature of no more than 260 ºC for less than 5 seconds.
Note:
1) All Pins: Material - Copper Alloy;
Finish – 3 micro inches minimum Gold over 50 micro inches minimum Nickel plate.
2) Undimensioned components are shown for visual reference only.
3) All dimensions in inches (mm); Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm).
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
9
ISOLATED DC/DC CONVERTERS
18 Vdc - 75 Vdc Input
12 Vdc /7 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Apr. 28, 2011
Revision History
Date
Revision
2011-04-28
D
Changes Detail
Approval
Add P/N 0RCY-60U12B without heatsink.
XF Jiang
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
2011 Bel Fuse Inc. Specifications subject to change without notice. 042811
10
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com