EMERSON-NETWORKPOWER PTH03050Y_09

Embedded Power for
Business-Critical Continuity
Rev. 3.23.09_137
PTHxx050Y Series
of 5
PTHxx050Y
3.3/5/12 Vin
Total Power:
# of Outputs:
10.8 Watts
Single
Specifications
Input
Special Features
Input current:
No load
10 mA
• VTT bus termination output
(output the system VREF)
• 6 A output current (8 A peak)
• 3.3, 5, or 12 Vdc input voltage
• DDR and QDR compatible
• ON/OFF inhibit ( for VTT standby)
• Under-voltage lockout
• Operating temperature range:
-40 °C to +85 °C
• Efficiencies up to 88%
• Output overcurrent protection
(non-latching, auto-reset)
• Point-of-Load-Alliance (POLA)
compatible
• Available RoHS compliant
• 2 Year Warranty
Input voltage range:
PTH03050Y
PTH05050Y
PTH12050Y
2.95 - 3.65 Vdc
4.5 - 5.5 Vdc
10.8 - 13.2 Vdc
PTH03050Y
Vin increasing
Vin decreasing
2.45 V typ., 2.80 V max.
2.20 V min., 2.40 V typ.
PTH05050Y
Vin increasing
Vin decreasing
4.30 V typ., 4.45 V max.
3.40 V min., 3.70 V typ.
PTH12050Y
Vin increasing
Vin decreasing
9.5 V typ., 10.4 V max.
8.80 V min., 9.0 V typ.
PTH03050Y & PTH05050Y
PTH12050Y
470 µF
Undervoltage lockout:
Input capacitance:
(See Note 4, page 3)
Remote ON/OFF:
560 µF
Active high
All specifications are typical at nominal input, VREF = 1.25 V, full load at 25 °C unless otherwise stated
Cin, Co1, C Co2 = typical value
Safety
• UL/cUL CAN/CSA-C22.2
No. 60950
File No. E174104
• TÜV Product Service (EN60950) Certificate No.
B 04 06 38572 044
• CB Report and Certificate to IEC60950, Certificate No. US/8292/UL
Embedded Power for
Business-Critical Continuity
Rev. 3.23.09_137
PTHxx050Y Series
of 5
Specifications Continued
Output
Output current:
(over �
VREF range)
All models
Continuous (See Note 1, page 3)
Repetitive pulse (See Note 2, page 3)
±6A
±8A
Tracking range for VREF:
0.55 - 1.8 V
Tracking tolerance to VREF (VTT - VREF):
(over line, load & temperature)
-10 mV to + 10 mV
Ripple and noise:
20 MHz bandwidth
Load transient response:
(See Note 5, page 3)
20 mV pk-pk
80 ����������������
µs settling time
Overshoot/undershoot 25 mV typ.
Output capacitance:
Non-ceramic values
(See Notes 5 & 6, page 3)
PTH03050Y
PTH05050Y
PTH12050Y
470 �����������������������
µF typ., 3,300 µF max.
470 �����������������������
µF typ., 3,300 µF max.
940 �����������������������
µF typ., 3,300 µF max.
Ceramic values
(See Note 5, page 3)
PTH03050Y
PTH05050Y
PTH12050Y
200 ���������������������
µF typ., 300 µF max.
200 ���������������������
µF typ., 300 µF max.
400 ���������������������
µF typ., 600 µF max.
(See Note 7, page 3)
ESR (non-ceramic)
4 mΩ min.
General Specifications
Efficiency:
lo = 4 A
PTH03050Y
PTH05050Y
PTH12050Y
Insulation voltage:
Switching frequency:
88% typ.
87% typ.
84% typ.
Non-isolated
PTH03050Y
PTH05050Y
PTH12050Y
550 - 650 kHz
550 - 650 kHz
200 - 300 kHz
Approvals and standards:
EN60950
UL/cUL60950
Material flammability:
UL94V-0
Dimensions:
(L x W x H)
Weight:
MTBF:
22.10 x 12.57 x 8.50 mm
0.870 x 0.495 x 0.335 in
2.9 g (0.10 oz)
Telcordia SR-332
6,000,000 hours
Thermal Performance:
(See Note 2, page 3)
Operating ambient, temperature
Non-operating
-40 °C to +85 °C
-40 °C to +125 °C
MSL (‘Z’ suffix only):
JEDEC J-STD-020C
Level 3
All models
12 A typ.
Environmental Specifications
Protection
Overcurrent threshold (auto reset):
Embedded Power for
Business-Critical Continuity
Rev. 3.23.09_137
PTHxx050Y Series
of 5
Ordering Information
Output Power
(max)
Input
Voltage
M�������������
odel Numbers (9, 10)
Max
Efficiency
(max)
Range
Min
10.8 W
2.95 - 3.65 Vdc
0.55 - 1.8 Vdc
0A
±6A
88%
PTH03050Y
10.8 W
4.5 - 5.5 Vdc
10.8 W
10.8 - 13.2 Vdc
0.55 - 1.8 Vdc
0A
±6A
88%
PTH05050Y
0.55 - 1.8 Vdc
0A
±6A
85%
PTH12050Y
VTT
Output Currents
Part Number System with Options
PTH05050YAST
Product Family
Point of Load Alliance
Compatible
Input Voltage
03 = 3.3 V, 05 = 5 V
and 12 = 12 V
Output Current
05 = 6 A
Mechanical Package
Always 0
Packaging Options
No Suffix = Trays
T = Tape and Reel (8)
Mounting Option (9)
D = Horizontal Through-Hole (RoHS 6/6)
H = Horizontal Through-Hole (RoHS 5/6)
S = Surface-Mount Solder Ball (RoHS 5/6)
Z = Surface-Mount Solder Ball (RoHS 6/6)
Pin Option
A = Through-Hole Std. Pin Length (0.140”)
A = Surface-Mount Tin/Lead Solder Ball
Output Voltage Code
Y = DDR Module
Notes
1 Rating is conditional on the module being soldered to a 4 layer PCB
with 1 oz. copper. See the SOA curves or contact the factory for
appropriate derating. The PTH03050Y and PTH05050Y require no
dearting up to 85 °C operating temperature and natural convection
airflow.
2 Up to 10 ms pulse period at 10% maximum duty.
3 This control pin has an internal pull-up to the input voltage Vin. If
it is left open-circuit the module will operate when input power is
applied. A small low-leakage (< 100 nA) MOSFET is recommended
for control. For further information, consult Application Note 178.
4 An input capacitor is required for proper operation. The capacitor
must be rated for a minimum of 300 mA rms (750 mA rms for 12 V
input) of ripple current.
5 The typical value of external output capacitance value ensures that
VTT meets the specified transient performance requirements for
the memory bus terminations. Lower values of capacitance may
be possible when the measured peak change in output current is
consistently less than 3 A. Test conditions were 15 A/µs load step,
-1.5 A to +1.5 A.
5 This is the calculated maximum. The minimum ESR limitation will
often result in a lower value. Consult Application Note 178 for
further details.
6 This is the typical ESR for all the electrolytic (non-ceramic) output
capacitance. Use 7 mΩ as the minimum when using max-ESR
values to calculate.
7 Tape and reel packaging only available on the surface-mount
versions.
8 To order Pb-free (RoHS compatible) surface-mount parts replace
the mounting option ‘S’ with ‘Z’, e.g. PTHXX050YAZ. To order Pbfree (RoHS compatible) through-hole parts replace the mounting
option ‘H’ with ‘D’, e.g. PTHXX050YAD.
9 NOTICE: Some models do not support all options. Please contact
your local Emerson Network Power representative or use the on-line
model number search tool at http://www.PowerConversion.com to
find a suitable alternative.
Embedded Power for
Business-Critical Continuity
Rev. 3.23.09_137
PTHxx050Y Series
of 5
AMBIENT TEMPERATURE (ºC)
Characteristic Data
8
80
70
60
Nat conv
50
40
OUTPUT CURRENT (A)
90
6
5
Nat conv
100 LFM
200 LFM
4
3
2
1
30
20
0
0
1
2
3
4
5
0
6
10
20
40
50
60
70
80
AMBIENT TEMPERATURE (ºC)
OUTPUT CURRENT (C)
Figure 2 - Safe Operating Area
Vin = 12 V, VREF = 1.25 V, Iout = 6 A (See Note A)
Figure 1 - Safe Operating Area
Vin = 3.3 V, VREF = 1.25 V, Iout = 6 A (See Note A)
Vin
100
VREF
VDDQ
90
1
1k
1%
80
3
Vin
3.3V
5.0V
12.0V
70
60
2
1k
1%
4
Cin
(Required)
Standby
+
VTT
6
PTHxx050Y
(Top View)
Con
hf-Ceramic
5
Co1
Low-ESR
(Required)
+ Co2
Ceramic
(Optional)
Q1
BSS138
(Optional)
GND
50
0
1
2
3
4
5
6
OUTPUT CURRENT (A)
Figure 3 - Efficiency vs Load Current
VREF = 1.25 V (See Note B)
Notes
A SOA curves represent the conditions at which internal components are within
the Emerson Network Power derating guidelines.
B Characteristic data has been developed from actual products tested at 25 °C. This data is considered typical data for the converter.
Figure 4 - Standard Application
VTT Termination Island
EFFICIENCY (%)
30
SSTL-2
Data/
Address/
Bus
Embedded Power for
Business-Critical Continuity
Mechanical Drawings
­Americas
0.140
(3.55)
0.870 (22.10)
0.060
(1.52)
0.060
(1.52)
0.750 (19.06)
0.125
(3.18)
0.125
(3.18)
0.125
(3.18)
ø0.040 (1.02)
6 Places
6
1
Rev. 3.23.09_137
PTHxx050Y Series
of 5
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
2
0.375 0.495
(12.57)
(9.52)
3
Lowest Component
0.010 min. (0.25)
Bottom side Clearance
5
4
0.070 (1.78)
(Standoff Shoulder)
TOP VIEW
Host Board
0.335 (8.50)
MAX.
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
SIDE VIEW
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places 0.030 (0.76)
3 Places 0.010 (0.25)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
For global contact, visit:
Figure 5 - Plated Through-Hole
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
0.870 (22.10)
0.060
(1.52)
0.125
(3.18)
0.125
(3.18)
0.125
(3.18)
0.060
(1.52)
0.750 (19.06)
*After solder reflow
on customer board
0.335 (8.50)
max.*
6
1
2
Solder Ball
ø0.040 (1.02)
6 Places
0.495
0.375 (12.57)
(9.52)
3
Lowest Component
0.010 min. (0.25)
Bottom side Clearance
5
4
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
SIDE VIEW
TOP VIEW
Host Board
DC Power
Embedded Computing
Embedded Power
Monitoring
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places 0.030 (0.76)
3 Places 0.010 (0.25)
Outside Plant
Power Switching & Controls
Figure 6 - Surface-Mount
Pin Connections
Precision Cooling
Racks & Integrated Cabinets
Pin Connections cont.
Pin No.
Function
Pin No.
Function
Pin 1
Ground
Pin 4
Inhibit*
Pin 2
VREF
Pin 5
N/C
Pin 3
Vin
Pin 6
VTT
Services
Surge Protection
* Denotes negative logic: Open = Normal operation
Ground = Function active
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2008 Emerson Electric Co.