Embedded Power for Business-Critical Continuity Rev. 3.23.09_137 PTHxx050Y Series of 5 PTHxx050Y 3.3/5/12 Vin Total Power: # of Outputs: 10.8 Watts Single Specifications Input Special Features Input current: No load 10 mA • VTT bus termination output (output the system VREF) • 6 A output current (8 A peak) • 3.3, 5, or 12 Vdc input voltage • DDR and QDR compatible • ON/OFF inhibit ( for VTT standby) • Under-voltage lockout • Operating temperature range: -40 °C to +85 °C • Efficiencies up to 88% • Output overcurrent protection (non-latching, auto-reset) • Point-of-Load-Alliance (POLA) compatible • Available RoHS compliant • 2 Year Warranty Input voltage range: PTH03050Y PTH05050Y PTH12050Y 2.95 - 3.65 Vdc 4.5 - 5.5 Vdc 10.8 - 13.2 Vdc PTH03050Y Vin increasing Vin decreasing 2.45 V typ., 2.80 V max. 2.20 V min., 2.40 V typ. PTH05050Y Vin increasing Vin decreasing 4.30 V typ., 4.45 V max. 3.40 V min., 3.70 V typ. PTH12050Y Vin increasing Vin decreasing 9.5 V typ., 10.4 V max. 8.80 V min., 9.0 V typ. PTH03050Y & PTH05050Y PTH12050Y 470 µF Undervoltage lockout: Input capacitance: (See Note 4, page 3) Remote ON/OFF: 560 µF Active high All specifications are typical at nominal input, VREF = 1.25 V, full load at 25 °C unless otherwise stated Cin, Co1, C Co2 = typical value Safety • UL/cUL CAN/CSA-C22.2 No. 60950 File No. E174104 • TÜV Product Service (EN60950) Certificate No. B 04 06 38572 044 • CB Report and Certificate to IEC60950, Certificate No. US/8292/UL Embedded Power for Business-Critical Continuity Rev. 3.23.09_137 PTHxx050Y Series of 5 Specifications Continued Output Output current: (over � VREF range) All models Continuous (See Note 1, page 3) Repetitive pulse (See Note 2, page 3) ±6A ±8A Tracking range for VREF: 0.55 - 1.8 V Tracking tolerance to VREF (VTT - VREF): (over line, load & temperature) -10 mV to + 10 mV Ripple and noise: 20 MHz bandwidth Load transient response: (See Note 5, page 3) 20 mV pk-pk 80 ���������������� µs settling time Overshoot/undershoot 25 mV typ. Output capacitance: Non-ceramic values (See Notes 5 & 6, page 3) PTH03050Y PTH05050Y PTH12050Y 470 ����������������������� µF typ., 3,300 µF max. 470 ����������������������� µF typ., 3,300 µF max. 940 ����������������������� µF typ., 3,300 µF max. Ceramic values (See Note 5, page 3) PTH03050Y PTH05050Y PTH12050Y 200 ��������������������� µF typ., 300 µF max. 200 ��������������������� µF typ., 300 µF max. 400 ��������������������� µF typ., 600 µF max. (See Note 7, page 3) ESR (non-ceramic) 4 mΩ min. General Specifications Efficiency: lo = 4 A PTH03050Y PTH05050Y PTH12050Y Insulation voltage: Switching frequency: 88% typ. 87% typ. 84% typ. Non-isolated PTH03050Y PTH05050Y PTH12050Y 550 - 650 kHz 550 - 650 kHz 200 - 300 kHz Approvals and standards: EN60950 UL/cUL60950 Material flammability: UL94V-0 Dimensions: (L x W x H) Weight: MTBF: 22.10 x 12.57 x 8.50 mm 0.870 x 0.495 x 0.335 in 2.9 g (0.10 oz) Telcordia SR-332 6,000,000 hours Thermal Performance: (See Note 2, page 3) Operating ambient, temperature Non-operating -40 °C to +85 °C -40 °C to +125 °C MSL (‘Z’ suffix only): JEDEC J-STD-020C Level 3 All models 12 A typ. Environmental Specifications Protection Overcurrent threshold (auto reset): Embedded Power for Business-Critical Continuity Rev. 3.23.09_137 PTHxx050Y Series of 5 Ordering Information Output Power (max) Input Voltage M������������� odel Numbers (9, 10) Max Efficiency (max) Range Min 10.8 W 2.95 - 3.65 Vdc 0.55 - 1.8 Vdc 0A ±6A 88% PTH03050Y 10.8 W 4.5 - 5.5 Vdc 10.8 W 10.8 - 13.2 Vdc 0.55 - 1.8 Vdc 0A ±6A 88% PTH05050Y 0.55 - 1.8 Vdc 0A ±6A 85% PTH12050Y VTT Output Currents Part Number System with Options PTH05050YAST Product Family Point of Load Alliance Compatible Input Voltage 03 = 3.3 V, 05 = 5 V and 12 = 12 V Output Current 05 = 6 A Mechanical Package Always 0 Packaging Options No Suffix = Trays T = Tape and Reel (8) Mounting Option (9) D = Horizontal Through-Hole (RoHS 6/6) H = Horizontal Through-Hole (RoHS 5/6) S = Surface-Mount Solder Ball (RoHS 5/6) Z = Surface-Mount Solder Ball (RoHS 6/6) Pin Option A = Through-Hole Std. Pin Length (0.140”) A = Surface-Mount Tin/Lead Solder Ball Output Voltage Code Y = DDR Module Notes 1 Rating is conditional on the module being soldered to a 4 layer PCB with 1 oz. copper. See the SOA curves or contact the factory for appropriate derating. The PTH03050Y and PTH05050Y require no dearting up to 85 °C operating temperature and natural convection airflow. 2 Up to 10 ms pulse period at 10% maximum duty. 3 This control pin has an internal pull-up to the input voltage Vin. If it is left open-circuit the module will operate when input power is applied. A small low-leakage (< 100 nA) MOSFET is recommended for control. For further information, consult Application Note 178. 4 An input capacitor is required for proper operation. The capacitor must be rated for a minimum of 300 mA rms (750 mA rms for 12 V input) of ripple current. 5 The typical value of external output capacitance value ensures that VTT meets the specified transient performance requirements for the memory bus terminations. Lower values of capacitance may be possible when the measured peak change in output current is consistently less than 3 A. Test conditions were 15 A/µs load step, -1.5 A to +1.5 A. 5 This is the calculated maximum. The minimum ESR limitation will often result in a lower value. Consult Application Note 178 for further details. 6 This is the typical ESR for all the electrolytic (non-ceramic) output capacitance. Use 7 mΩ as the minimum when using max-ESR values to calculate. 7 Tape and reel packaging only available on the surface-mount versions. 8 To order Pb-free (RoHS compatible) surface-mount parts replace the mounting option ‘S’ with ‘Z’, e.g. PTHXX050YAZ. To order Pbfree (RoHS compatible) through-hole parts replace the mounting option ‘H’ with ‘D’, e.g. PTHXX050YAD. 9 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.PowerConversion.com to find a suitable alternative. Embedded Power for Business-Critical Continuity Rev. 3.23.09_137 PTHxx050Y Series of 5 AMBIENT TEMPERATURE (ºC) Characteristic Data 8 80 70 60 Nat conv 50 40 OUTPUT CURRENT (A) 90 6 5 Nat conv 100 LFM 200 LFM 4 3 2 1 30 20 0 0 1 2 3 4 5 0 6 10 20 40 50 60 70 80 AMBIENT TEMPERATURE (ºC) OUTPUT CURRENT (C) Figure 2 - Safe Operating Area Vin = 12 V, VREF = 1.25 V, Iout = 6 A (See Note A) Figure 1 - Safe Operating Area Vin = 3.3 V, VREF = 1.25 V, Iout = 6 A (See Note A) Vin 100 VREF VDDQ 90 1 1k 1% 80 3 Vin 3.3V 5.0V 12.0V 70 60 2 1k 1% 4 Cin (Required) Standby + VTT 6 PTHxx050Y (Top View) Con hf-Ceramic 5 Co1 Low-ESR (Required) + Co2 Ceramic (Optional) Q1 BSS138 (Optional) GND 50 0 1 2 3 4 5 6 OUTPUT CURRENT (A) Figure 3 - Efficiency vs Load Current VREF = 1.25 V (See Note B) Notes A SOA curves represent the conditions at which internal components are within the Emerson Network Power derating guidelines. B Characteristic data has been developed from actual products tested at 25 °C. This data is considered typical data for the converter. Figure 4 - Standard Application VTT Termination Island EFFICIENCY (%) 30 SSTL-2 Data/ Address/ Bus Embedded Power for Business-Critical Continuity Mechanical Drawings Americas 0.140 (3.55) 0.870 (22.10) 0.060 (1.52) 0.060 (1.52) 0.750 (19.06) 0.125 (3.18) 0.125 (3.18) 0.125 (3.18) ø0.040 (1.02) 6 Places 6 1 Rev. 3.23.09_137 PTHxx050Y Series of 5 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone:+1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) 2 0.375 0.495 (12.57) (9.52) 3 Lowest Component 0.010 min. (0.25) Bottom side Clearance 5 4 0.070 (1.78) (Standoff Shoulder) TOP VIEW Host Board 0.335 (8.50) MAX. Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone:+852 2176 3333 Facsimile: +852 2176 3888 SIDE VIEW Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Places 0.030 (0.76) 3 Places 0.010 (0.25) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone:+44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 For global contact, visit: Figure 5 - Plated Through-Hole www.PowerConversion.com techsupport.embeddedpower @emerson.com 0.870 (22.10) 0.060 (1.52) 0.125 (3.18) 0.125 (3.18) 0.125 (3.18) 0.060 (1.52) 0.750 (19.06) *After solder reflow on customer board 0.335 (8.50) max.* 6 1 2 Solder Ball ø0.040 (1.02) 6 Places 0.495 0.375 (12.57) (9.52) 3 Lowest Component 0.010 min. (0.25) Bottom side Clearance 5 4 While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity SIDE VIEW TOP VIEW Host Board DC Power Embedded Computing Embedded Power Monitoring Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Places 0.030 (0.76) 3 Places 0.010 (0.25) Outside Plant Power Switching & Controls Figure 6 - Surface-Mount Pin Connections Precision Cooling Racks & Integrated Cabinets Pin Connections cont. Pin No. Function Pin No. Function Pin 1 Ground Pin 4 Inhibit* Pin 2 VREF Pin 5 N/C Pin 3 Vin Pin 6 VTT Services Surge Protection * Denotes negative logic: Open = Normal operation Ground = Function active EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.