Jumbo-LED ELJ-525-617 16.11.2007 rev. 04 Radiation Type Technology Case Green 3W InGaN/Al2O3 Plastic lens, metal case High-power green LED in an aluminium case with thread socket, for easy handling and heat sink mounting 1,5 Ø11 Ø1,7 Ø16 Ø12,5 Description 4,5 5,08 7,9 Outline: 2 H = 12.4 mm (± 0.5) Illumination, sensors and optical communications, medical appliances, measurement systems D = 16 mm (± 0.5) 8 Applications 13 Thread M10 1 2 Pin 1 – cathode Pin 2 – anode M10 Absolute Maximum Ratings at Tamb = 25°C, on heat sink (S ≥ 200 cm²), unless otherwise specified Test сonditions Symbol Value Unit on heat sink IF 0.7 A tp≤10 µs, f≤500 Hz IFM 1.2 A Power dissipation on heat sink P 2,8 W Operating temperature range on heat sink Tamb -25 to +100 °C Storage temperature range on heat sink Tstg -25 to +100 °C Junction temperature on heat sink Tj 100 °C Typ Max Unit 3.8 V Parameter DC forward current Peak forward current Electrical Characteristics Tamb = 25°C, unless otherwise specified Parameter Test conditions Symbol Min Forward voltage IF = 100 mA VF 3.0 Forward voltage* IF = 350 mA VF 3.5 V Switching time IF = 350 mA tr, tf 40/50 ns Reverse voltage IR = 10 µA VR 10 K/W Thermal resistance junction-case *only recommended on optimal heat sink RthJC 5 We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 1 of 5 Jumbo-LED ELJ-525-617 16.11.2007 rev. 04 Optical Characteristics at Tamb = 25°C, on heat sink (S ≥ 200 cm²), unless otherwise specified Test Parameter Symbol Min conditions Typ Max Unit Radiant power IF = 100 mA Φe Radiant power* IF = 350 mA Φe Radiant intensity IF = 100 mA Ιe Radiant intensity* IF = 350 mA Ιe Luminous intensity IF = 100 mA Ιv Luminous intensity* IF = 350 mA Ιv Peak wavelength IF = 100 mA λp Dominant wavelength* IF = 350 mA λp 527 nm Spectral bandwidth at 50% IF = 100 mA ∆λ0.5 40 nm Viewing angle IF = 100 mA ϕ 13 deg 11 140 60 515 14 mW 35 mW 180 mW/sr 460 mW/sr 76,5 cd 180 cd 525 535 nm *only recommended on optimal heat sink Note: All measurements carried out with EPIGAP equipment, on blank aluminium heat sink, S = 180 cm², passive cooling. Measurement results and curve characteristics obtained with other heat sinks may differ. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 2 of 5 Jumbo-LED ELJ-525-617 16.11.2007 rev. 04 We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 3 of 5 Jumbo-LED ELJ-525-617 16.11.2007 rev. 04 Remarks concerning optical radiation safety* For low forward current (<150 mA) and continuous operation, this LED may be classified as LED product Class 2 , according to standard IEC 60825-1:A2. Class 2 products emit in the visible region, damaging exposure is usually prevented through avert reactions including blink reflex. It can be expected that these reactions provide sufficient protection under reasonably predictable conditions. This also implicates a direct observation of the light beam by means of optical instruments. If intended to operate at higher current, this product has to be classified as LED product Class 2M , according to standard IEC 60825-1:A2. Class 2M products are safe to eyes and skin under normal conditions, including when users view the light beam directly. These products emit in the visible region and it is presumed that the human blink reflex will be sufficient to prevent damaging exposure, but if the beam is focused down, damaging levels of radiation may be reached. Therefore, users should not incorporate optics that could concentrate the output into the eyes. *Note: Safety classification of an optical component mainly depends on the intended application and the way the component is being used. Furthermore, all statements made to classification are based on calculations and are only valid for this LED "as it is", and at continuous operation. Using pulsed current or altering the light beam with additional optics may lead to different safety classifications. Therefore these remarks should be taken as recommendation and guideline only. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 4 of 5 Jumbo-LED ELJ-525-617 16.11.2007 rev. 04 Handling precautions To prevent damage to the LED during soldering and assembly, following precautions have to be taken into account. a) The bending point of the lead frame should be located at least 2.5 mm away from the body. b) While bending, the base of the lead frame has to be fixed with radio pliers or similar. c) To ensure an adequate strain relief, the lead frames have to be firmly fixed during soldering. d) Avoid any torsion or tensile loading of the lead frames, especially when they have been heated after being soldered. e) LEDs are static sensitive devices, so adequate handling precautions have to be taken, e.g. wearing grounding wrist straps. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 5 of 5