FCI FBR3060

30 Amp SCHOTTKY
BARRIER RECTIFIERS
FBR3030 . . . 3060 Series
Data Sheet
Mechanical Dimensions
Description
Case
JEDEC
T0-3P
1
2
CASE
3
Common Cathode Suffix ‘‘C’’
1
1
2
3
3
2
CASE
Common Anode Suffix ‘‘A’’
Features
n HIGH CURRENT CAPABILITY
WITH LOW VF
n HIGH SURGE VOLTAGE AND
TRANSIENT PROTECTION
n HIGH EFFICIENCY w/LOW POWER LOSS
n MEETS UL SPECIFICATION 94V-0
FBR3030 . . . 3060 Series
Units
FBR3030 FBR3035 FBR3040 FBR3045 FBR3050 FBR3060
Maximum Ratings
Peak Repetitive Reverse Voltage...VRRM
30
35
40
45
50
60
Volts
Working Peak Reverse Voltage...VRWM
30
35
40
45
50
60
Volts
DC Blocking Voltage...VDC
30
35
40
45
50
60
Volts
RMS Reverse Voltage...VR(rms)
21
24
28
31
35
42
Volts
Average Forward Rectified Current...IO
@ TC = 110°C VR (equiv.) < = 0.2VR(DC)
............................................. 3 0 ...............................................
Amps
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Load Conditions, ½ Sine Wave, Single Phase, 60Hz
............................................. 300 ...............................................
Amps
Operating Temperature Range...TJ
........................................ -65 to 150 .........................................
°C
< ........................ .55 ........................ > < ........ .65 ......... >
Volts
Electrical Characteristics
Maximum Forward Voltage...VF
@ IF = 15 Amps
Maximum DC Reverse Current...IR
@ Rated DC Blocking Voltage
Page 7-36
TC = 25°C
TC =150°C
............................................. 3.0 ............................................... mAmps
............................................. 100 ............................................... mAmps
30 Amp SCHOTTKY
BARRIER RECTIFIERS
Typical Reverse Characteristics
FBR3030..45
FBR3050...3060
FBR3030...3045
Reverse Current (mA)
Average Forward Current (A)
Forward Current Derating Curve
Case Temperature (oC)
Reverse Voltage (V)
Typical Reverse Characteristics
FBR3050..60
Reverse Current (mA)
Junction Capacitance (pF)
Typical Junction Capacitance
FBR3030 . . . 3060 Series
Data Sheet
Reverse Voltage (V)
Reverse Voltage (V)
Peak Forward Surge Current
Forward Current (A)
Peak Forward Surge Current (A)
Typical Forward Characteristics
Forward Voltage (V)
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
Single Phase Half
Wave, 60 Hz
Resistive or
Inductive Load.
Number of Cycles @ 60 Hz
For Capacitive
Load, Derate
Current by 20%.
Page 7-37