FCI FBR3090

30 Amp 90 & 100V SCHOTTKY
BARRIER RECTIFIERS
FBR3090 & 30100 Series
Data Sheet
Mechanical Dimensions
Description
.900
.200
2 plcs.
.670
.75
.175
JEDEC
T0-3P
.200
.050 Typ
Features
n HIGH CURRENT CAPABILITY
WITH LOW VF
n HIGH SURGE VOLTAGE AND
TRANSIENT PROTECTION
n HIGH EFFICIENCY w/LOW POWER LOSS
n MEETS UL SPECIFICATION 94V-0
Electrical Characteristics @ 25o C.
Units
FBR3090 & 30100
FBR3090
FBR30100
Peak Repetitive Reverse Voltage...VRRM
90
100
Volts
Working Peak Reverse Voltage...VRWM
90
100
Volts
DC Blocking Voltage...VDC
90
100
Volts
RMS Reverse Voltage...VR(rms)
21
42
Volts
Maximum Ratings
Average Forward Rectified Current...IO
@ TC = 110°C VR (equiv.) < = 0.2VR(DC)
............................................. 3 0 ...............................................
Amps
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Load Conditions, ½ Sine Wave, Single Phase, 60HZ
............................................. 3 0 0 ...............................................
Amps
Forward Voltage...VF
@ IF = 15 Amps
............................................. .55 ...............................................
Volts
DC Reverse Current...IR
@ Rated DC Blocking Voltage
Operating Temperature Range...T J
Page 7-38
T C = 25°C
T C =150°C
............................................. 1 0 ............................................... mAmps
............................................. 1 0 0 ............................................... mAmps
......................................... -65 to 150 ..........................................
°C
Typical Reverse Characteristics
FBR3030..45
FBR3050...3060
Amps
FBR3030...3045
Reverse Current (mA)
Forward Current Derating Curve
Case Temperature (oC)
Reverse Voltage (Volts)
Typical Reverse Characteristics
FBR3050..60
pF
Reverse Current (mA)
Typical Junction Capacitance
Reverse Voltage (Volts)
Common Cathode,
Suffix "C"
Reverse Voltage (Volts)
Typical Forward Characteristics
Peak Forward Surge Current
Amps
2
Case
Amps
1
FBR3090 & 3100
30 Amp 90 & 100V SCHOTTKY
BARRIER RECTIFIERS
Data Sheet
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
3
Number of Cycles @ 60 Hz
Forward Voltage (Volts)
NOTES: 1. Measured @ 1 MHZ and applied reverse voltage of 4.0V.
2. Thermal Resistance Junction to Case, Jedec Method.
3. When Mounted to heat sink, from body.
Single Phase Half
Wave, 60 HZ
Resistive or
Inductive Load.
For Capacitive
Load, Derate
Current by 20%.
Page 7-39