FCI VF30C60

30 Amp SUPERFAST
POWER RECTIFIERS
VF30C05 . . . 60 Series
PreliminaryData Sheet
Mechanical Dimensions
Description
TO 3P
1
2
CASE
3
Double Suffix ‘‘D’’
1
3
1
2
CASE
Common Anode Suffix ‘‘A’’
2
CASE
3
Common Cathode Suffix ‘‘C’’
Features
n LOW FORWARD VOLTAGE
n SUPERFAST RECOVERY TIME
n HIGH SURGE CAPABILITY
n MEETS UL SPECIFICATION 94V-0
Electrical Characteristics @ 25o C.
VF30C05 . . . 60 Series
Maximum Ratings
Units
05
10
15
20
30
40
50
60
Peak Repetitive Reverse Voltage...VRRM
50
100
150
200
300
400
500
600
Volts
Working Peak Reverse Voltage...VRWM
50
100
150
200
300
400
500
600
Volts
DC Blocking Voltage...VDC
50
100
150
200
300
400
500
600
Volts
RMS Reverse Voltage...VR(rms)
35
70
105
140
210
280
350
420
Volts
Average Forward Rectified Current...IF(av)
TC = 150°C @ Rated VDC
............................................. 15 ...............................................
............................................. 30 ...............................................
Amps
Amps
Repetitive Peak Forward Surge Current...IFM
@ Rated VDC, Square Wave, 20 KHZ, TC = 150°C
............................................. 30 ...............................................
Amps
............................................. 300 ...............................................
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Load Cond., ½ Wave, Single Phase, 60HZ
Amps
Forward Voltage...VF
@ IF = 15 Amps, PW = 300µs
DC Reverse Current...IR
@ Rated DC Blocking Voltage
TC = 150°C
TC = 25°C
< ................... 1.0 .................... > < ... 1.1 .... > < ...... 1.3 ..... >
< ................... 1.4 .................... > < ... 1.4 .... > < ...... 1.6 ..... >
Volts
Volts
TC =150°C
TC = 25°C
< ................... 2 5 0 .................. > < ................. 5 0 0 .............. >
< ................... 5.0 .................. > < .................. 1 0 .............. >
µAmps
µAmps
Reverse Recovery Time...tRR
IF = 1.0 Amp, di/dt = 50 Amps/µS
< .............................
5 0 ................................ > < ...... 7 5 ... >
nS
Operating & Storage Temperature Range...TJ, TSTRG
............................................. -65 to 175 .......................................
°C
15
Forward Current Derating Curve
Non-Repetitive
Peak Forward Surge Current
Amps
Amps
10
5
Number of Cycles @ 60 HZ
0
VF30C05 . . . 60 Series
30 Amp SUPERFAST
POWER RECTIFIERS
Preliminary Data Sheet
25 50 75 100 125 150 175
TA = Ambient Temperature (°°C)
Typical Reverse Characteristics
Typical Junction Capacitance
pF
Amps
1000
500
200
100
50
10
1
Percent of Rated Peak Voltage
Typical Instantaneous
Forward Characteristics
10
(-)
50Ω
Ω
25 VDC
Reverse Recovery
Characteristics
Ω
D.U.T 10Ω
1Ω
NonInductive
(-)
Pulse
Generator
Note 2
Oscilliscope (+)
Note 1
Notes:
Volts
100
Reverse Voltage (Volts)
Non-Inductive
(+)
Amps
1
1. Rise Time = 7 nS Max.
Impedance = 1 megohm, 22 pF
2. Rise Time = 10 nS Max.
Source Impedance = 50 Ohms
+.5A
tRR
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
0A
-.25A
-1.0A
1 cm
Time Base Set @ 50/100nS/cm
Single Phase Half
Wave, 60 HZ
Resistive or
Inductive Load.
For Capacitive
Load, Derate
Current by 20%.