MEANWELL PD-65

PD-65
65W Dual Output Switching Power Supply
series
Features :
Universal AC input / Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
PD-65B
PD-65A
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
5.5A
2.8A
3.5A
2A
CURRENT RANGE
0.4 ~ 7A
0.2 ~ 3.2A
0.4 ~ 6A
0.2 ~ 2.6A
RATED POWER
61.1W
OUTPUT POWER (max.)
Rated output power for convection; 72W with 18CFM min. Forced air
65.5W
RIPPLE & NOISE (max.) Note.2 50mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 4.0%
INPUT
1.0%
2.0%
LOAD REGULATION
3.0%
4.0%
3.0%
4.0%
SETUP, RISE TIME
800ms, 20ms at full load
HOLD UP TIME (Typ.)
60ms at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 440Hz
EFFICIENCY(Typ.)
78%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.5A/115VAC
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
127 ~370VDC
81%
0.9A/230VAC
COLD START 20A/115VAC
<0.75mA
40A/230VAC
73 ~ 105W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
CH1: 5.75 ~ 6.75VDC on CH1
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.04%/ (0 ~ 50 ) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
DIMENSION
PACKING
NOTE
7.0%
2.0%
PROTECTION
OTHERS
7.0%
150mVp-p
1.0%
OVERLOAD
(Note 4)
CH1:4.75 ~ 5.5V
4.0%
LINE REGULATION
LEAKAGE CURRENT
EMC
50mVp-p
414.8K hrs min. MIL-HDBK-217F (25
127*76*42mm (L*W*H)
0.24Kg; 54pcs/15Kg/1.35CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
File Name:PD-65-SPEC 2011-08-18
PD-65
65W Dual Output Switching Power Supply
Mechanical Specification
series
Unit:mm
127
5.6
115.8
5.6
FG
HS1
M1
M2
CN1
1
64.8
76
CN2
1
2
3
4
5
6
2
FS1
AC FUSE
F4A/250V
HS2
SVR1
3.
8
42
4-
AC Input Connector (CN1) : Molex 5277-02 or equivalent
Pin No.
1
2
Assignment
AC/N
AC/L
Mating Housing
Terminal
Molex 5195
or equivalent
Molex 5194
or equivalent
DC Output Connector (CN2) : Molex 5273-06 or equivalent
Pin No.
1
2,3
4,5
6
HS1,HS2 can not be shorted
Assignment
+V
+5V
COM
NC
Mating Housing
Terminal
Molex 5195
or equivalent
Molex 5194
or equivalent
Block Diagram
fosc : 65KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
FG
Derating Curve
+V
RECTIFIERS
&
FILTER
+5V
COM
DETECTION
CIRCUIT
PWM
CONTROL
O.L.P.
RECTIFIERS
&
FILTER
O.V.P.
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD(%)
LOAD (%)
60
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
60
50
40
90
100
110
135
155
230 264
INPUT VOLTAGE (V) 60Hz
File Name:PD-65-SPEC 2011-08-18