MEDER SIL12-1A72-71L

MEDER electronic
SIL Series
Single-In-Line
Reed Relays
DESCRIPTION
Single-In-Line Reed Relays reduce the required
space to a minimum. Requiring only half the PCB
area of the DIP or DIL series, the SIL relays offer all
the advantages of Reed Technology.
FEATURES
CHARACTERISTICS
• High resistance coils of up to 2000 Ω at 12 VDC
• Breakdown voltage coil / contact of up to 4.25 kVDC
• Contact form 1A, 1B or 1C
• Magnetic shield available
• High resistance version
• Other coil resistances available
• Option with coax screen for Z=50 Ohm
Impedance
DIMENSIONS
All dimensions in mm [inch]
20.6
[0.811]
8.3
[0.327]
5.9
[0.232]
PIN OUT
View from top of component, 2.54mm [0.10”] pitch grid
71 Form 1A
1
3
+
5
71 Form 1B
7
1
3
+
5
51 Form 1C
7
“+” by option with diode
www.meder.com
198
1
2
3
+
5
7
SIL Series
MEDER electronic
Single-In-Line
Reed Relays
RELAY DATA
All Data at 20° C
Switch Model →
Contact Form →
Contact Ratings
Conditions
Switch 31
Form A
Switch 72
Form A
Min. Typ. Max. Min. Typ. Max. Units
Switching Power
Any DC combination of V & A
not to exceed their individual
max.‘s
50
15
W
Switching Voltage
DC or peak AC
500
200
V
Switching Current
DC or peak AC
2
1.0
A
Carry Current
DC or peak AC
2
1.25
A
Static Contact Resistance
w/ 0.5 V & 10mA
80
150
mΩ
Dynamic Contact Resistance
Measured w/ 0.5 V & 50mA ,
1.5 ms after closure
200
mΩ
Insulation Resistance across
Contacts
Across Contact
Coil - Contact
1011
1013
Ω
Breakdown Voltage across
Contact
Across Contact
Coil - Contact
1500
2000
250
1500
VDC
Operate Time incl. Bounce
Nominal voltage
1.2
0.7
ms
Release Time
with no coil suppression
1.0
0.1
ms
Capacitance
Across Contact
Coil - Contact
0.3
DC <10 pF stray cap.
100
0.2
2.0
pF
Life Expectance
Switch Voltage 5V - 10 mA
106
Cycles
1000
For other load requirements, see the life test section on P. 120.
Environmental Data
Shock Resistance
1/2 sinus wave duration
11 ms
50
50
Vibration Resistance
From 10 - 2000 Hz
10
20
Ambient Temperature
10°C/ minute max. allowable
-20
70
-20
Stock Temperature
10°C/ minute max. allowable
-35
95
-35
Soldering Temperature
5 sec.
260
260
g
g
70
o
C
95
o
C
o
C
* 600 VDC with 5V coil, 1000 VDC with 12V coil.
www.meder.com
199
MEDER electronic
SIL Series
Single-In-Line
Reed Relays
RELAY DATA
All Data at 20° C
Switch Model →
Contact Form →
Contact Ratings
Conditions
Switch 75
Form A
Switch 90
Form B/C
Min. Typ. Max. Min. Typ. Max. Units
Switching Power
Any DC combination of V & A
not to exceed their individual
max.‘s
10
3
W
Switching Voltage
DC or peak AC
500
175
V
Switching Current
DC or peak AC
0.5
0.25
A
Carry Current
DC or peak AC
1.0
1.2
A
Static Contact Resistance
w/ 0.5 V & 10mA
200
150
mΩ
Dynamic Contact Resistance
Measured w/ 0.5 V & 50mA ,
1.5 ms after closure
200
250
mΩ
Insulation Resistance across
Contacts
Across Contact
Coil - Contact
1013
109
1012
Ω
Breakdown Voltage across
Contact
Across Contact
Coil - Contact
1500*
1500
200
1500
VDC
Operate Time incl. Bounce
Nominal voltage
0.5
0.7
ms
Release Time
with no coil suppression
0.1
1.5
ms
Capacitance
Across Contact
Coil - Contact
0.4
2.0
1.0
4.0
pF
100
106
Cycles
Life Expectance
Switch Voltage 5V - 10 mA
DC <10 pF stray cap.
500
For other load requirements, see the life test section.
Environmental Data
Shock Resistance
1/2 sinus wave duration
11 ms
30
50
Vibration Resistance
From 10 - 2000 Hz
10
20
Ambient Temperature
10°C/ minute max. allowable
-20
70
-20
Stock Temperature
10°C/ minute max. allowable
-35
95
-35
Soldering Temperature
5 sec.
260
* 600 VDC with 5V coil, 1000 VDC with 12V coil.
www.meder.com
200
g
g
70
o
C
95
o
C
260
o
C
SIL Series
MEDER electronic
Single-In-Line
Reed Relays
COIL DATA
Contact
Form
Switch
Model
Coil
Resistance
VDC
All Data
at 20 °C
31
1A
Coil
Voltage
72
75
72
1B
90
1C
90
Ω
Nom.
Max.
Min.
Typ.
Max.
Pull In
Voltage
Drop Out
Voltage
Nominal
Coil Power
VDC
VDC
mW
Max.
Min.
Typ.
5
7.5
72
80
88
3.5
0.75
312
12
16
450
500
550
8.4
1.8
288
5
7.5
450
(180)**
500
(200)
550
(220)
3.5
0.75
50
(125)
12
16
900
1000
1100
8.4
1.8
145
15
7.5
1800
2000
2200
10.5
2.2
110
24
30
1800
2000
2200
16.8
3.6
290
5 HR
7.5
900
1000
1100
3.5
0.75
25
12 HR
16
1800
2000
2200
8.4
1.8
70
3
4.5
450
500
550
2.1
0.45
18
5
7.5
180
200
220
3.5
0.75
125
12
12
900
1000
1100
8.4
1.8
145
5
7.5
180
200
220
3.5
0.75
125
* The pull-in / drop out voltages and coil resistance will change at the rate of 0,4 % / °C.
** Data in () are valid for switch models 75 and 84.
ORDER INFORMATION
Part Number Example
SIL12 - 1A72 - 71L
12 is the nominal voltage
1A is the contact form
72 is the switch model
L is the option
OPTIONS
L
M
D
Q
= No option
= With magnetic shield
= With diode and
no magnetic shield
= With diode and
with magnetic shield
Series
Nominal
Voltage
Contact
Form
Switch
Model
Pin Out
Options
High
Resistance
Version
SIL
XX -
1X
XX -
XX
X
XX
03, 05, 12,
15, 24*
1A
31, 72, 75
71
L, M, D, Q
05, 12
1A
72
71
L, M, D, Q
05
1B
90
71
L, M, D, Q
05
1C
90
51
L, M, D, Q
Options
HR
* Other coil resistance available. Please consult factory.
www.meder.com
201