MPSIND P8E2R4VA-16

2.4VA 50Hz/60Hz LINE
TRANSFORMER
P8E2R4VA SERIES
• RoHS Compliant Product
• Hipot: 2500VRMS (Primaries to Secondaries)
• Class A (105°C) UL1411 equivalent
• Operating Temperature: -40°C to +105°C
ELECTRICAL SPECIFICATION @ 25°C
Primary
Secondary RMS Rating
115V input (1+3, 2+4)
Series Output (5-8)
Connect 6+7
230V input (1-4 with 2+3)
Parallel Output (5-6)
Connect 5+7, 6+8
Part No
Voltage
Current
Voltage
Current
P8E2R4VA-
(V)
(A)
(V)
(A)
10
12R6
16
20
24
28
36
48
56
120
10
12.6
16
20
24
28
36
48
56
120
0.250
0.200
0.150
0.120
0.100
0.085
0.065
0.050
0.045
0.020
5
6.3
8
10
12
14
18
24
28
60
0.500
0.400
0.300
0.240
0.200
0.170
0.130
0.100
0.090
0.040
Mechanical
Schematic
Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ± 0.015 .XXX : ±0.004
mm: X,X : ± 0,38 X,XX : ±0,10
Product performance is limited to specified parameter. Data is subject to change without prior notice.
2463 208th, Ste. 205
Torrance, CA 90501
Phone: (310)533-1455
Fax:
(310)533-1853
P8E2R4VA-XXX
0606JW
http://www.mpsind.com
Email: [email protected]