05064 587B062LPE thru Only One Name Means ProTek’Tion™ 587B302LPE LOW PROFILE 240V AC POWER LINE SURGE SUPPRESSOR APPLICATIONS ✔ Hard Wired Equipment AC Power Protection ✔ Load Side Distribution Systems ✔ Secondary Protection for Light Industrial AC Power IEC COMPATIBILITY (EN61000-4) ✔ 61000-4-5 (Surge): 1kA, 8/20µs - Level 4(Line-Line) FEATURES U.S PATENT 4,563,720 Meets ANSI/IEEE C62.41 Outdoor Requirements Listed to CSA, File LR65240 (Except 587B302LPE) Differential Mode Protection Low Clamping Voltage Nanosecond Response Time Long Life and Maintenance Free Finger Safe Connectors FIGURE 1 TRANSIENT VOLTAGE THREAT CONDITION 8 6 Kilovolts ✔ ✔ ✔ ✔ ✔ ✔ ✔ MECHANICAL CHARACTERISTICS 4 2 ✔ Plastic Package ✔ Weight: 360 Grams (Approximate) ✔ Flammability Rating UL 94V-0 ✔ Device Marking: Part Number, Date Code, Logo, Voltage and Current Rating 0 0 10 20 30 40 50 60 Time - µs FIGURE 2 TYPICAL CLAMPING ACTION OF A 15 AMP MODULE DESCRIPTION 6 4 Kilovolts The 587B Low Profile (LPE) Series is designed for European applications where no line to ground or neutral to ground suppression is allowed. These modules employ a three stage technology proven to be the most cost effective and reliable method in protecting sensitive electronic equipment from over voltage transients. 2 0 This series is designed to protect AC powered equipment from the 6,000 Volt peak open circuit voltage and 3,000 Amp short circuit current as defined in ANSI/IEEE C62.41, Category CI. The 587BxxxLPE Series offers a high degree of protection against 240 VAC EMI line noise. It is ideal for protecting 800 Volt components because the solid state TVS technology assures that the line-to-neutral voltage will not exceed 800 Volts. While the modules are designed for transient voltage protection, the advanced circuitry will also attenuate the amplitude and slow the rate of rise of high frequency noise acting as an EMI filter. The 587BxxxLPE Series includes common mode protection, which are effective in reducing interference from line to equipment and are effective in reducing equipment generated noise to meet FCC, VDE and CSA interference requirements. 05064.R4 12/03 1 0 10 20 30 Time - µs 40 50 60 Figures 1 and 2 are photographs of digitized waveforms showing the typical clamping action of a 16 ampere module. A 12 Ohm resistor is used to represent a 10 Amp equipment load. The load is then subjected to the ANSI/IEEE C62.41 Category CI test conditions (6,000V/3,000A). These photographs contrast the effect on equipment with and without the protector. www.protekdevices.com 587B062LPE thru 587B302LPE DEVICE CHARACTERISTICS SPECIFICATIONS @ 25°C RESPONSE TO TRANSIENT VOLTAGES MAXIMUM RATINGS Operating Line Voltage: 240 VAC +10% Maximum Line Current: 587B062LPE: 5A 587B102LPE: 10A 587B162LPE: 16A 587B302LPE: 30A Transient Voltage: 6000Vpeak Transient Current: 3000Apeak Current Leakage: @ 240 VAC Line-to-Neutral: 1.0mA Storage & Operating -40°C to 85°C Temperature: (Measured at center of mounting surface) CLAMPING TEST CONDITION PROTECTION MODE MAXIMUM CLAMPING VOLTAGE OPEN CIRCUIT VOLTAGE @ 1.2/50 µs SHORT CIRCUIT CURRENT @ 8/20 µs DIFFERENTIAL (Line-to-Neutral) 800V 6000V 3000A COMMON (Neutral-to-Ground) (Line-to-Ground) N/A N/A N/A ARRESTER DEFINITIONS Clamping Voltage: The clamping voltage of an arrester is the voltage that appears across its terminals during conduction of a transient current. Standard Wave Form: The waveform of a surge current or voltage is designated by a combination of two numbers. The first number is for the time of the wave front expressed in microseconds from zero to the peak of the wave. The second number is for the time of the wavetail also expressed in microseconds from zero to the instant that the wavetail reaches one half of the crest or peak value, i.e., 8/20 µs waveform. Transient Current: The transient current of an arrestor is the peak surge current which flows through the arrester when voltage clamping occurs. OPERATION For maximum effectiveness, the protector should be installed directly after the AC line on/off switch and fuse. This will protect the electronics from the AC line switch arcing and the severe transients caused by a fuse clearing. Some heat is produced when operating at full current load, and heat sinking may be required to maintain case temperature below 85°C. The case temperature is measured at the center of the mounting surface. The unit should not be mounted to a low combusting temperature material such as wood. High energy transients will cause a large circulating current in the AC input line (2,500A is possible). To prevent electromagnetic coupling, the AC line on the input side of the protector must be dressed away from other wiring, magnetic shielding may be required. In addition, the electrical service must be connected to a low impedance earth ground. 05064.R4 12/03 2 www.protekdevices.com 587B062LPE thru 587B302LPE PACKAGE OUTLINE & DIMENSIONS 3.81” (96.8 mm) 1.63” (44.14 mm) 1.10” (27.9 mm) 3.50” (88.9 mm) 0.586” (14.43 mm) 2.30” (58.42 mm) 4.38” (111.3 mm) Note: Connector accepts 10-24 gauge wire. Line 1 Out Line In Dia 0.181” SURGEBUSTER ® AC LINE SURGE SUPPRESSOR 587B162LPE Neutral In Ground In Line 2 Out Neutral 1 Out Neutral 2 Out ® 240 VAC 50/60 Hz 16A Ground Out MADE IN USA COPYRIGHT © ProTek Devices 2003 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products. 05064.R4 12/03 3 ProTek Devices 2929 South Fair Lane, Tempe, AZ 85282 Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: [email protected] Web Site: www.protekdevices.com www.protekdevices.com