RHOMBUS-IND T

T1/CEPT PULSE TRANSFORMER
UL 1459 Recognized
Turns Ratio ( + 5% )
R
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
1CT:1CT
PARAMETER
MIN.
MAX.
1.2
Open Circuit Inductance
UNITS
mH
Leakage Inductance
0.8
µH
Interwinding Capacitance (CW/W)
25
pF
Primary DC Resistance
0.8
ohms
Secondary DC Resistance
0.8
ohms
1.5 Kv
Isolation (HI-POT)
Temperature Characteristics:
-40o C 700 µH min.
(40% drop in inductance)
+85o C 1.4 mH min.
(15% growth in inductance)
Typical part:
VRMS
TEST CONDITIONS:
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz
Inductance measured on either winding.
1.7 mH @ +25o C
2.0 mH @ +85o C
1.0 mH @ -40o C
Parts shipped in anti-static
tubes. 50 pieces per tube
PHYSICAL DIMENSIONS
All dimensions in inches (mm)
SCHEMATIC DIAGRAM
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-10225
CUST P/N:
DATE: 1/24/94
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971