RHOMBUS-IND T

T1/CEPT PULSE TRANSFORMER
UL 1459 Recognized
Turns Ratio ( + 5% )
PARAMETER
Open Circuit Inductance
R
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
1:4CT
MIN.
MAX.
0.5
UNITS
mHy
Leakage Inductance
1.0
µHy
Interwinding Capacitance (CW/W)
40
pF
Primary DC Resistance
0.5
ohms
Secondary DC Resistance
1.5
ohms
Isolation (HI-POT)
1.5 Kv
VRMS
TEST CONDITIONS:
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz
Inductance measured on Primary winding. Pins 1 - 5.
Temperature Characteristics:
-40o C 300 µH min. (40% drop in
inductance)
+85o C 575 µH min. (15% growth in
inductance)
Typical part:
700 µH @ +25o C
805 µH @ +85o C
420 µH @ -40o C
Parts shipped in anti-static
tubes. 50 pieces per tube
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM:
5
6
4
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-10217
1
Rhombus
Industries Inc.
Transformers & Magnetic Products
2
CUST P/N:
DATE: 1/24/94
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649