RHOMBUS-IND T

U Interface Transformer (2B1Q Coding Applications)
Designed for use with National TP 3410
Turns Ratio ( + 3 % ) (Line : Chip)
1.50 : 1
PARAMETER
MIN.
MAX.
UNITS
Primary Inductance (Line Side)
25.4
28.6
mH
20
ohms
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Pins 1 to 5 with 2 & 4 shorted.
Primary DC Resistance
Schematic Diagram
Secondary DC Resistance
3.0
Isolation (Hi-Pot)
ohms
2000
DC Bias
PRI
lin e
VRMS
60
SEC
d e vice
mA
Return Loss 10KHz & 25 KHz
20
dB
Longitudinal Balance
(281 Hz to 40 KHz)
55
dB
NOTE:
Operating Temp. Range -400C to +850C
Primary is Line Side (Pins 1,2,4,5)
Secondary is Chip Side (Pins 7,8,9)
Surge Voltage Capability
.570
(14.48)
MAX.
1.070
(27.18)
REF.
Metallic Voltage: 800 V peak, 10/560 µS
.470
(11.94)
MAX.
.900
(22.86)
REF.
Longitudinal Voltage: 2400 V peak, 10/700 µS
10
1
Top View
1.19
(30.23)
2
9
3
8
4
7
5
6
.040
(1.02)
TYP.
.920
(23.37)
MAX.
.150
(3.81)
TYP.
.150
(3.81)
Physical Dimensions
inches (mm)
.080
(2.03)
.180
(4.57)
.090
(2.29)
TYP.
Notch Indicates Pin #1
1.10 (27.94)
1.04 (26.42)
RHOMBUS P/N: T-13212G
CUST P/N:
DATE: 7/2/96
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com