RHOMBUS-IND T-1408

Fly Back Transformer
Turns Ratio
1 : 1.2 : 1.2
Schematic Diagram
Parameter
Min.
Typ.
Max.
Units
Inductance
1-2
59.4
66
72.6
µH
DC Resistance 1-2
32
mΩ
DC Resistance 6-5
73
mΩ
DC Resistance 7-8
73
mΩ
Hi-Pot (1-2) to (6,5,7,8)
500
2
7
1
8
6
5
VRMS
Physical Dimensions
inches (mm)
TOP VIEW
RHOMBUS P/N: T-1408
CUST P/N:
DATE: 4/26/00
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com