RHOMBUS-IND T

PARAMETER
UNITS
Turns Ratio
DIAGRAM
1 : 1 +2%
Primary Impedance
Secondary Impedance
600
600
Ω
Ω
Insertion Loss : 1 kHz
1.0 Max.
dB
Frequency Response:
200 Hz - 100 kHz
+2
dB
200 Hz
1 kHz
10 kHz
20 Min.
30 Min.
25 Min.
dB
dB
dB
Primary DC Resistance
55 Max.
Ω
Secondary DC Resistance
70 Max.
Ω
Isolation (HI-POT)
1500
VRMS
Primary DC
None
Return Loss :
2
9
4
7
Typical applications: telephone
sets, PBXs, DLC systems,
central office switches.
Optomized insertion loss and
return loss for audio frequency
range, including voiceband.
Physical Dimensions
in inches (mm)
.522
(13.26)
MAX.
.715
(18.15)
.532
(13.51)
MAX.
1
2
.516
(13.1)
MAX.
3
10
Suggested
Pad Layout
4
.100
(2.54)
.028
(0.70)
.025
(0.64)
8
7
5
.050
(1.27)
TYP.
6
.100
(2.54)
TYP.
.516
(13.1)
9
.100
(2.54)
TYP.
.675 (17.15)
.663 (16.85)
RHOMBUS P/N: T-30411G
CUST P/N:
DATE: 11-29-00
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971