Electrical Specifications at 25OC
Parameter
PRI.
600
Ω
SEC.
600
Ω
Turns Ratio (+2%)
1:1.1036
Direct Current in Pri. (DCI)
maximum
120
mA
PRI. + 10%
57.5
Ω
SEC. + 10%
99
Ω
max., ref. 1 kHz
1.3
dB
Return Loss
min., 300 Hz
11
dB
Echo Return Loss
min.18.0
dB
DC Resistance
Insertion Loss
Frequency Response
300 Hz to 3.5 kHz
+ 0.5
dB
T.H.D.
typ. 300 Hz, 0 dBm
-55
dB
minimum
2200
VDC
Isolation
Low Profile Coupling
Transformer
Units
Impedance
Schematic
Diagram
PRI
SEC
Longitudinal Balance
Meets FCC Part 68.310 (a) requirements
Insulation Resistance
*
>100MΩ @500 VDC
*Copper foil shield terminated to
pin #6 and core.
Physical Dimensions
inches (mm)
5
1
6
2
7
3
8
4
RHOMBUS P/N: T-31008
CUST P/N:
DATE: 3/21/97
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971