RHOMBUS-IND T-600

Modem Coupling Transformer
Turns Ratio ( + 3 % )
Schematic Diagram
1:1
PARAMETER
MIN.
NOM.
MAX.
UNITS
Impedance primary
600
Ω
Impedance secondary
374
Ω
D.C. Resistance Pri.
97.2
108
118
Ω
D.C. Resistance Sec.
108
120
132
Ω
Return Loss at 1kHz
30
60
dB
Longitudinal Balance at
1kHz to 4 kHz
40
dB
Total Harmonic Distortion
600, 10 dBm
Frequency Response
-76
1250
200 Hz to 4 kHz
Insertion Loss at 1 kHz
4
2
3
dB
Longitudinal Balance 60-1000 Hz
Dielectric Test PRI-SEC
1
Compatible with 56 kb/s technologies
dB
VAC
+0.25 dB
Low distortion, specifically designed for
use from V.32bis through V.34
Flat Frequency/phase response
2.0 +0.25 dB
Physical
Dimensions
inches (mm)
.450
(11.43)
.880
(22.35)
3
4
2
2
1.03
(26.16)
MAX.
.450
(11.4)
3
Bottom
View
1
1
4
.550
(14.0)
RHOMBUS P/N: T-600
CUST P/N:
DATE: 11/3/99
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com