SANKEN RH3G

Damper Diodes (For TV)
Electrical Characteristics (Ta = 25°C)
Absolute Maximum Ratings
Parameter
VRM
(V)
I F (AV)
(A)
RH 10F
1500
0.8
RH 2D
1300
Type No.
Tj
(°C)
IFSM
(A)
Tstg
(°C)
IR
(µA)
VF
(V)
50Hz
Half-cycle Sinewave
Single Shot
max
60
1.0
t rr ➀
(µs)
IR (H)
(µA)
IF /IRP
(mA)
VR = VRM
VR = VRM
max
Ta =100°C max
IF
(A)
1.0
10
Others
t rr ➁
(µs)
IF /IRP
(mA)
Rth (j- )
Mass
(°C/ W)
(g)
15.0
0.44
A
12.0
0.6
B
10.0
1.0
C
8.0
1.2
D
Fig.
10/10
1.0
RH 2F
500
4.0
–40 to +150
1500
1.3
100/200
RH 3F
1.3
RH 3G
1600
RH 4F
1500
2.5
50
50
2.5
100/100
1.5
10
350
RH 10F, 2D, 2F
,2
F
RH
10
0.6
F
0.4
0.1
Ta = 150ºC
100ºC
60ºC
25ºC
0.01
0.2
0
0
25 40 50 60 75
100 125
Ambient Temperature Ta (°C)
0.001
0.2
150
0.4
0.6
0.8
1.0
Forward Voltage VF (V)
60
50
20ms
40
30
20
10
0
1.2
I FSM (A)
I FSM (A)
0
Peak Forward Surge Current
Forward Current IF (A)
2D
I F (AV) (A)
0.8
I FMS Rating
10
RH
Average Forward Current
VF —IF Characteristics (Typical)
Ta—IF(AV) Derating
1.0
1
5
10
Overcurrent Cycles
50
RH 3F, 3G
1.5
1.0
0.5
0
0
25
50
75
100 125
Ambient Temperature Ta (°C)
0.1
Ta = 150ºC
100ºC
60ºC
25ºC
0.01
0.3
0.5
0.7 0.9 1.1
Forward Voltage VF (V)
50
I FSM (A)
I FSM (A)
0
0.001
0.1
150
Peak Forward Surge Current
P. C. B. t 1.6
Solder Land 10mm
2.0
I FMS Rating
20
10
10mm
Forward Current IF (A)
I F (AV) (A)
Average Forward Current
VF —IF Characteristics (Typical)
Ta—IF(AV) Derating
2.5
30
20
10
0
1.3
20ms
40
1
5
10
Overcurrent Cycles
50
RH 4F
ith
W
ith
ou
tH
ea
ts
in
k
He
1.5
ats
ink
1.0
0.1
Ta = 150ºC
100ºC
60ºC
25ºC
0.01
0.5
25
50 60 75
100 125
Ambient Temperature Ta (°C)
External Dimensions
0.001
0.1
150
0.78
±0.05
4.0 ±0.2
20
10
1
5
10
Overcurrent Cycles
50
Fig. D
1.2±0.05
±0.05
1.4 ±0.1
Cathode Mark
Cathode Mark
Cathode Mark
62.5 ±0.7
7.2±0.2
4.0 ±0.2
30
0
1.3
Fig. C
0.98
Cathode Mark
62.5±0.7
0.5
0.7 0.9 1.1
Forward Voltage VF (V)
Fig. B
Fig. A
(Unit: mm)
Flammability:
UL94V-0 or Equivalent
0.3
62.5 ±0.7
0
7.2±0.2
0
I FSM (A)
I FSM (A)
0
20ms
40
5.2±0.2
8.0 ±0.2
2.0
50
50.0 ±1.0
5mm
9.1±0.2
5mm
Peak Forward Surge Current
2.5
Forward Current IF (A)
I F (AV) (A)
I FMS Rating
20
10
20•20•1t Cu
W
Average Forward Current
VF —IF Characteristics (Typical)
Ta—IF(AV) Derating
3.0
6.5 ±0.2
69