SECOS SFG08S1200

SFG08S1200
Voltage 1200V
8.0 Amp Super Fast Rectifier
Elektronische Bauelemente
RoHS Compliant Product
A suffix of “-C” specifies and halogen free
TO-220YA
FEATURES
Fast switching for high efficiency
Low noise
TRR = 35ns
Low reverse leakage current
High voltage super FRD
PFC application
MECHANICAL DATA
Case:Molded plastic TO-220Y
Epoxy:UL 94V-0 rate flame retardant
Terminals:Solderable per MIL-STD-202
method 208
Mounting position:Any
Weight:2.07 grams
REF.
A
B
C
D
E
F
G
H
Millimeter
Min.
Max.
10.5
1.58
1.82
1.33
1.45
15.3
16.2
3.50
3.91
2.90
3.25
1.22
1.43
0.68
0.94
REF.
I
J
K
L
M
N
P
Q
Millimeter
Min.
Max.
12.90
13.35
4.44
4.70
1.14
1.40
5.84
6.86
2.25
2.60
0.35
0.64
1.7
4.95
5.20
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
Rating
Unit
Recurrent Peak Reverse Voltage
VRRM
1200
V
Maximum RMS Voltage
VRMS
840
V
Maximum DC Blocking Voltage
VDC
1200
V
IF(AV)
8
A
IFSM
100
A
VF
3.2
V
Maximum Average Forward Rectified
Current TC=140°C
Peak Forward Surge Current,8.3ms single Half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage @ 8.0A
Maximum DC Reverse Current At Rated
TJ=25°C
DC Blocking Voltage
TJ=150°C
Maximum Reverse Recovery Time
Typical Junction Capacitance
Typical Thermal Resistance
100
IR
1
2
3
Operating Junction and Storage Temperature Range
µA
500
TRR
35
nS
CJ
25
pF
RθJC
2
°C / W
TJ, TSTG
-65~175
°C
Notes:
1. Reverse recovery test conditions IF= 0.5A, IR= 1.0A, IRR= 0.25A.
2. Junction Capacitance test conditions : VR =10V,IF=0A
3. Thermal Resistance junction to case.
http://www.SeCoSGmbH.com/
06-Sep-2011 Rev. A
Any changes of specification will not be informed individually.
Page 1 of 2
SFG08S1200
Elektronische Bauelemente
Voltage 1200V
8.0 Amp Super Fast Rectifier
RATINGS AND CHARACTERISTICS CURVE
http://www.SeCoSGmbH.com/
06-Sep-2011 Rev. A
Any changes of specification will not be informed individually.
Page 2 of 2