E L E C T R O N I C MBR40L100CT Power Schottky Rectifier - 40Amp 100Volt □ Features -Plastic package has Underwriters Laboratory Flammability Classifications 94V-0 -High Junction Temperature Capability -Low forward voltage, high current capability -High surge capacity -Low power loss, high efficiency -ESD performance human body mode > 8 KV TO-220AB L B □ Application -AC/DC Switching Adaptor and TFT-LCD Power Supply -SMPS M C D K A □ Absolute maximum ratings E Symbol Ratings Unit Conditions IF(AV) 40 A Average Forward Current F O Repetitive Peak Reverse G VRRM 100 V IFSM 400 A Peak Forward Surge Current VF(max) 0.66 V Forward Voltage Drop A1 Tj -50 to +175 ºC Operating Temperature A2 Tstg -50 to +150 ºC Storage Temperature Maximum Instantaneous Forward Voltage Maximum Reverse Leakage Current Maximum Voltage Rate of Change Typical Thermal Resistance, Junction to Case Symbol Conditions 0.82V Tc = 25ºC 0.66V Tc = 125ºC 0.01mA Tc = 25ºC 10mA Tc = 125ºC dv/dt 10,000 V/μs Rated VR Rθ (j-c) 2.2 ºC/W Per diode IR H H N K DIM Ratings VF J Voltage □ Electrical characteristics Parameters I A B C D E F G H I J K L M N O DIMENSIONS INCHES MM MAX MIN MAX MIN .579 .606 14.70 15.40 .392 .411 9.95 10.45 .104 .116 2.65 2.95 .248 .272 6.30 6.90 .325 .350 8.25 8.90 .126 .157 3.20 4.00 .492 .551 12.50 14.00 .096 .108 2.45 2.75 .028 .039 0.70 1.00 .010 .022 0.25 0.55 .146 .157 3.70 4.00 .167 .187 4.25 4.75 .045 .057 1.15 1.45 .089 .114 2.25 2.90 .047 .055 1.20 1.40 NOTE Note: Pulse Test : 380μs pulse width, 2% duty cycle August 2008 / Rev.6.1 http:// www.sirectsemi.com 1 MBR40L100CT 1000 REVERSE CURRENT, IR(mA) 1000 TJ=175℃ TJ=150℃ 10 TJ=125℃ 1 TJ=100℃ TJ=75℃ 0.1 TJ=50℃ 0.01 TJ=25℃ TJ=175℃ TJ=125℃ TJ=25℃ 0.001 0 20 40 60 80 100 REVERSE VOLTAGE, V R(V) 10 Figure 2. Typical Values Of Reverse Current Vs. Reverse Voltage (PerLeg) JUNCTION CAPACITANCE, CT(pF) 1000 1 TJ=25℃ 0.1 0 0.4 0.8 1.2 1.6 2 100 0 20 FORWARD VOLTAGE DROP, V FM(V) 40 60 80 100 REVERSE VOLTAGE, V R(V) Figure 1. Max. Forward Voltage Drop Characteristics (PerLeg) Figure 3. Typical Junction Capacitance Vs. Reverse Voltage (PerLeg) 10 THERMAL IMPEDANCE ZthJC (C/W) INSTANTANEOUS FORWARD CURRENT, IF(A) 100 100 1 D = 0.50 D = 0.33 D = 0.25 D = 0.17 0.1 D = 0.08 PDM t1 t2 0.01 Notes: 1.Duty factor D = t1 / t2 2.Peak Tj = PDM x ZthJC + TC SINGLE PULSE (THERMAL RESISTANCE) 0.001 0.0000 1 0.0001 0.001 0.01 0.1 1 10 100 t1, RECTANGULAR PULSE DURATION (SECONDS) Figure 4. Max. Thermal Impedance Z thJC Characteristics (PerLeg) http:// www.sirectsemi.com 2 MBR40L100CT 20 D = 0.20 170 AVERAGE POWER LOSS, WATTS ALLOWABLE CASE TEMPERATURE, ℃ 180 DC 160 150 140 SQUARE WAVE (D = 0.50) 80% RATED VR APPLIED 130 120 110 100 0 5 10 15 20 25 30 D = 0.25 D = 0.33 D = 0.50 15 D = 0.75 DC RMS LIMIT 10 5 0 35 0 AVERAGE FORWARD CURRENT, I F(AV) Figure 5. Max. Allowable Case Temperature Vs. Average Forward Current (PerLeg) 5 10 15 20 25 30 AVERAGE FORWARD CURRENT, I F(AV) Figure 6. Forward PowerLoss Characteristics (PerLeg) NON-REPETITIVE SURGE CURRENT, IFSM(A) 1000 AT ANY RATED LOAD CONDITION AND WITH RATED VRRM APPLIED FOLLOWING SURGE 100 10 100 1000 10000 SQUARE WAVE PULSE DURATION, TP(micro sec) Figure 7. Max. Non-Repetitive Surge Current (Per Leg) Sirectifier Global Corp., Delaware, U.S.A. U.S.A.: [email protected] France: [email protected] Taiwan: [email protected] Hong Kong: [email protected] China: [email protected] …Thailand: [email protected] Philippines: [email protected] Belize: [email protected] http:// www.sirectsemi.com 3