RID-50 50W Dual Output Switching Power Supply series Features : Isolated output & GND for CH1,CH2 Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty SPECIFICATION MODEL OUTPUT INPUT RID-50A RID-50B OUTPUT NUMBER CH1 CH2 CH1 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 6A 2A 4A 1.4A CURRENT RANGE 0.3 ~ 6A 0.3 ~ 3A 0.3 ~ 6A 0.2 ~ 2A RATED POWER 54W CH2 53.6W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 8.0% 80mVp-p 150mVp-p CH1: 4.75 ~ 5.5V 2.0% +8,-4% LINE REGULATION Note.4 0.5% 1.5% 0.5% 1.5% LOAD REGULATION Note.5 0.5% 5.0% 0.5% 5.0% SETUP, RISE TIME 500ms, 20ms/230VAC HOLD UP TIME (Typ.) 60ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 80% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.3A/115VAC 0.8A/230VAC COLD START 33A/230VAC LEAKAGE CURRENT 1200ms, 30ms/115VAC at full load 14ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 81% <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMC EMISSION (Note 6) EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 172.6Khrs min. MIL-HDBK-217F (25 99*97*36mm (L*W*H) 0.41Kg; 45pcs/19.5Kg/0.9CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:RID-50-SPEC 2011-08-19 RID-50 50W Dual Output Switching Power Supply Mechanical Specification 2 3.5 51.5 1 9.5 Unit:mm 36 Case No. 905B series 3 5.5 97 8.2 4 55.5 2- M 3 5 6 7 20.5 55 3.5 4.5 89 99 6.5 87 74 18 Pin No. 1 2 3 4 36 3 3.5 28 2-M 17.5 7 Terminal Pin No. Assignment 3.5 Assignment AC/L AC/N FG DC OUTPUT G2 Pin No. 5 6 7 Assignment DC OUTPUT +V2 DC OUTPUT G1 DC OUTPUT +V1 Block Diagram fosc : 50KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Output Derating VS Input Voltage Derating Curve Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -25 -25 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (VERTICAL) 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RID-50-SPEC 2011-08-19