UTC-IC TA31002_07

UNISONIC TECHNOLOGIES CO., LTD
TA31002
LINEAR INTEGRATED CIRCUIT
TELEPHONE TONE RINGER
DESCRIPTION
The UTC TA31002 is a bipolar integrated circuit designed for
telephone bell replacement. It can also be used as alarms or other
alerting devices.
FEATURES
*Current consumption is small. (at no-load)
*Package is compaction. (DIP-8 pin)
*Oscillation frequency is variable.
*Built-in threshold circuits prevent false triggering due
to power noise as well as “chirps” due to rotary dial.
*Few external components.
DIP-8
*Pb-free plating product number: TA31002L
ORDERING INFORMATION
Ordering Number
Normal
Lead Free Plating
TA31002-D08-T
TA31002L-D08-T
Package
Packing
DIP-8
Tube
TA31002L-D08-T
(1)Packing Type
(2)Package Type
(3)Lead Plating
www.unisonic.com.tw
Copyright © 2005 Unisonic Technologies Co., Ltd
(1) T: Tube
(2) D08: DIP-8
(3) Lead Free Plating, Blank: Pb/Sn
1 of 4
QW-R108-004.B
TA31002
LINEAR INTEGRATED CIRCUIT
PIN CONFIGURATIONS
Vcc
1
8
Output
RSL
2
7
High Freq.
Time Constant
Low Freq.
Time Constant
3
6
High Freq.
Time Constant
4
5
GND
Low Freq.
Time Costant
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 6
QW-R108-004.B
TA31002
LINEAR INTEGRATED CIRCUIT
BLOCK DIAGRAM
R1
4
3
C1
R2
C2
6
HIGH
OSC
LOW
OSC
1
7
AMP
8
OUTPUT
POWER SUPPLY (WITH HYSTERESIS)
5
2
Note:R1,R2,C1 and C2 are parts externally mounted
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 6
QW-R108-004.B
TA31002
LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATINGS (Ta=25°C)
PARAMETER
SYMBOL
RATINGS
UNIT
Power Supply Voltage
VCC
30
V
Power Dissipation
PD
800
mW
Operating Temperature
TOPR
-40 ~ +85
°C
Storage Temperature
TSTG
-55 ~ +150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
ELECTRICAL CHARACTERISTICS (Ta=25°C)
(All voltage referenced to GND unless otherwise specified)
PARAMETER
Operating Voltage
Initiation Supply Voltage
Sustaining Supply Voltage
Initiation Current Consumption
Sustaining Current Consumption
Oscillation Frequency (not3)
SYMBOL
VOPR
Vsi
Vsus
Isi
Isus
Fl
fH1
fH2
Output Voltage “H” Level
VOH
Output Voltage “L” Level
VOL
TEST CONDITIONS
(note 1)
(note 2)
No-Load
C1=0.47µF, R1=165kΩ
C2=6800pF, R2=191kΩ
Vcc=24V, VOH=-10mA
PIN7=GND
Vcc=24V, VOL=10mA
PIN7=7V
MIN
TYP
19
12
3.3
1.4
10
512
640
MAX
29
21
4.2
2.5
11
563
703
UNIT
V
V
V
mA
mA
Hz
Hz
Hz
17
10.5
1.4
0.7
9
461
576
20.0
21.5
22.5
V
0.7
1.0
2.0
V
*Note : 1. Initiation supply voltage (Vsi) is a supply voltage required to start oscillation of the tone ringer.
2. Sustaining supply voltage (Vsus) is a supply voltage required to maintain oscillation of the tone ringer.
3. Oscillation frequency is determined by the following equations 1, 2, and 3.
(1) fL=1/1.234•R1•C1 (Hz) ; (2)fH1=1/1.515•R2•C2 (Hz); (3)fH2=1.24 fH1(Hz)
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
4 of 6
QW-R108-004.B
TA31002
LINEAR INTEGRATED CIRCUIT
APPLICATION NOTE
In the UTC TA31002 the initiation current consumption (Isi) can be changed by using the RSL terminal. The
resistor RSL is connected to GND from PIN2 as shown in fig.1. Further, the initation current consumption (Isi) can
be changed by changing the value of RSL.
Fig.2 show the graph of Vs-Is characteristic at the time when RSL has been changed to three values. The Vs-Is
characteristic in UTC TA31002 at the time when RSL=6.8kΩ coincides with that at the time when PIN2 of the
TA31001 has been used at an open state.
Vs
LS
1
2
UTC TA31002
RSL
5
GND
FIG.1
Current Consumption
(mA)
RSL =3.3kΩ
RSL =6.8kΩ
RSL =13kΩ
Is 5
4
3
2
1
Vsus
10
Vsi
20
30
Vs
Supply Voltage (V)
FIG.2
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
5 of 6
QW-R108-004.B
TA31002
LINEAR INTEGRATED CIRCUIT
APPLICATION CIRCUIT
TIP
1 µF/250V
2KΩ
104B42
0.22μF
1
8
2
7
RSL
UTC
TA31002
D5Z27
RING
C4
15μF/35V
+
R2
3
6
4
5
C2
R1
-
C1
61Ω
SP
15kΩ
1300:8Ω
fL=1/1.234R1*C1
fH1=1/1.515R2*C2
fH2=1.24fH1
when:
R1=165KΩ
R2=191KΩ
C1=0.47µF/16V C2=0.0068µF/16V
fL≅10Hz
fH1≅500Hz
fH2≅630Hz
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
6 of 6
QW-R108-004.B