WELWYN FA1

Flameproof Metal
Film Resistors
Welwyn Components
FA Series
•
Approval to BS CECC 40101-019
and 40101-024
•
•
Resistance range 0.1 ohm to 1M ohm
Flameproof protection
Electrical Data
FA025
FA05
FA1
Power rating at 70°C
watts
0.5
1.0
1.5
FA94
2.0
Resistance range
ohms
0R1 to 1M
0R1 to 1M
0R1 to 1M
2R6 to 1M0
Limiting element voltage
volts
350
350
500
700
Isolation voltage
volts
500
500
700
1000
TCR
ppm/°C
150
Resistance tolerance
%
≤1 ohm: 5, 10 >1 ohm: 1, 2, 5
Ambient temperature range
°C
-55 to 155
* Approved CECC 40101-019 / 40101-024
FX
EX
DX
CX
Power rating at 70°C
watts
0.25
0.5
1.0
2.0
Resistance range
ohms
1 to 1M
1 to 1M
1 to 1M
10 to 100k
volts
250
350
500
700
volts
500
700
1000
1400
Limiting element voltage
Isolation voltage
**TCR
ppm/°C
250
Resistance tolerance
%
1, 2, 5
Ambient temperature range
°C
-55 to 125
Standard values
E24 preferred
Thermal impedance
°C/watt
140
110
90
60
*These specificatios are identical except that BS CECC 40101-024 includes flammability tests.
**Specification TCR - actual TCR as for commercial.
Physical Data
Dimensions (mm) & Weight (g)
L Max
D Max
f min
d nom
PCB
mounting
centres
FA025
6.2
2.5
21.0
0.6
10.2
0.6
0.3
FA05
9.0
3.6
19.6
0.8
12.7
1.2
0.5
FA1
14.5
5.3
23.6
0.8
20.3
1.2
1.1
FA94
13.1
5.9
29.5
0.8
19.5
1.2
1.1
Type
Min.
bend
radius
Wt.nom
d
D
L
f
General Note
Welwyn Components reserves the right to make changes in product specification without notice or liability.
All information is subject to Welwyn’s own data and is considered accurate at time of going to print.
A subsidiary of
TT electronics plc
© Welwyn Components Limited · Bedlington, Northumberland NE22 7AA, UK
Telephone: +44 (0) 1670 822181 · Facsimile: +44 (0) 1670 829465 · Email: [email protected] · Website: www.welwyn-tt.com
Issue B · 03.02
145
Flameproof Power
Metal Film Resistors
Welwyn Components
FA Series
Construction
Marking
The resistance element is a precisely controlled thin film of
metal alloy on a high purity ceramic core, protected by a
cement coating applied so that terminations remain
completely clear.
Resistors are colour coded with 4 bands.
IEC 62 colours are used.
Solvent Resistance
This permits a well defined body length, (clean lead to clean
lead dimension L).
The body protection and marking are resistant to all normal
industrial cleaning solvents suitable for printed circuits.
Flammability
Terminations
Material
Solder-coated copper wire.
Strength
The terminations meet the requirements of
IEC 68.2.21
The resistors will not burn or emit incandescent particles
under any condition of applied temperature or power
overload.
Solderability The terminations meet the requirements of
IEC 115-1, Clause 4.17.3.2
Performance Data
CECC 40101-019/40101-024
∆R %
Load at commercial rating: 1000 hrs at 70°C
Actual Performance
Requirements
Maximum
Typical
not specified
3
1
2
2
1
1
0.7
0.7
Load at CECC rating: 1000 hrs at 70°C
Load at 35% rated power: 1000 hrs at 125°C
∆R %
2
Dry heat: 1000 hours at 155°C
∆R %
not specified
1
Shelf life: 12 months at room temperature
∆R %
not specified
0.5
Derating
35% of rated power at 125°C
0.5
zero at 235°C
Short term overload
∆R %
0.5
0.2
0.02
Climatic
∆R %
2
0.5
0.5
Climatic category
∆R %
55/125/56
Long term damp heat
∆R %
2
2
0.5
Temperature rapid change
∆R %
0.5
0.25
0.05
Resistance to solder heat
∆R %
0.5
0.25
0.07
Vibration and bump
∆R %
0.5
0.1
0.01
Application Notes
Packaging
All FA Series resistors are normally supplied tape packed ready
for loading onto automatic sequencing and insertion
machines.
1. If the resistors are to dissipate full rated power, it is
recommended that the terminations should not be
soldered closer than 4mm from the body.
2. Due to operating temperature limitations imposed by some
pcb materials, derating may be necessary. An estimate of
the temperature rise to be expected can be calculated using
the thermal impedance figures given under Electrical Data.
Standard Quantities Per Package
Type
Large ammo pack
55/125/56
FA025
FA05
FA1
FA94
5000
2500
1000
1000
Component wires will not protrude beyond the outside edge
of the tapes.
Alternative packaging available by request.
Lead Formed resistors can also be supplied. Standard options
of Lancet, Radial and Goalpost forming are shown in Lead
Form Information section.
c
Type
b
c
FA025/FA05
52
5
FA1
67
10
FA94
77
10
f1
6
f2
b
6
Body Location f1 – f2 ≤ 1.4 mm
© Welwyn Components Limited Bedlington, Northumberland NE22 7AA, UK
Telephone: +44 (0) 1670 822181 · Facsimile: +44 (0) 1670 829465 · Email: [email protected] · Website: www.welwyn-tt.com
146
Issue B · 03.02