ZCOMM CRO3060A_10

CRO3060A
PHASE NOISE (1 Hz BW, typical)
14118 Stowe Drive, Suite B | Poway, CA 92064
TEL: (858) 621-2700 | FAX: (858) 486-1927
URL: www.zcomm.com
EMAIL: [email protected]
Rev A1
-40
Voltage-Controlled Oscillator
Surface Mount Module
Applications
• Point to Point Radio
• Fixed Wireless Equipment
• Satellite Communications
£(f) (dBc/Hz)
-60
Application Notes
-80
-100
-120
-140
-160
1000
10000
100000
• AN-101: Mounting and Grounding
• AN-102: Output Loading
• AN-107: Manual Soldering
OFFSET (Hz)
Performance Specifications
Min
Oscillation Frequency Range
3050
Typ
Max
Units
3070
MHz
Phase Noise @ 10 kHz offset (1 Hz BW)
-115
dBc/Hz
Harmonic Suppression (2nd)
-12
dBc
Tuning Voltage
0.5
4.5
MHz/V
8
Tuning Sensitivity (avg.)
6
dBm
Input Capacitance
50
pF
Pushing
1
MHz/V
Pulling (14 dB Return Loss, Any Phase)
1
MHz
85
°C
Max
Units
Power Output
2
Load Impedance
Operating Temperature Range
50
-40
Package Style
Power Supply Requirements
4
Vdc
MINI-16
Min
Typ
Supply Voltage (Vcc, nom.)
5
Supply Current (Icc)
19
Vdc
23
mA
Additional Notes
LFSuffix = RoHS Compliant. All specifications are subject to change without notice.
© Z-Communications, Inc. All Rights Reserved.
Page 1 of 2
FRM-S-002 B
CRO3060A
Voltage-Controlled Oscillator
Surface Mount Module
Rev A1
FREQUENCY (MHz)
Tuning Curve, typ.
3095
3085
3055
85 °C
25 °C
3045
-40 °C
3075
3065
3035
3025
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
TUNING VOLTAGE (Vdc)
POWER OUTPUT (dBm)
Power Curve, typ.
Footprint
RECOMMENDED FOOTPRINT
10
SEVERAL HOLES OF O 0.015 ON
GND. PLANE ARE RECOMMENDED
FOR GOOD GROUNDING.
9
8
7
6
5
4
0.030 MIN. CUTBACK
FROM LIVE PADS
3
2
1
0
3036
3042
3046
3050
3054
3058
3062
3067
3071
3076
FREQUENCY (MHz)
85 °C
25 °C
-40 °C
Physical Dimensions
PIN CONFIGURATION
Z-COMM
XXXXXXXX-LF
W/O#
D/C
P1
P2
P3
REST
Vt
RF OUT
Vcc
GROUND
PACKAGE
H
MINI-16
0.220
MINI-16-LOW
0.160
MINI-16-L
0.130
MINI-16-UL
0.100
MINI-16-EL
0.085
NOTE: ALL DIMENSIONS ARE IN INCHES
TOL: XXX: +/- 0.010
LFSuffix = RoHS Compliant. All specifications are subject to change without notice.
© Z-Communications, Inc. All Rights Reserved.
Page 2 of 2
FRM-S-002 B