AAC JXWBGF-T-3-2000-4000

Power Divider
The content of this specification may change without notification 7/01/09
Power Divider
Coaxial
General Power Divider (SMA Connectors)
Freq u e nc y
N-Wa y
I nse rtio n
Ra n ge
Lo ss
(G Hz)
(d B )
Iso lat ion
A mp lit ud e
P ha se
P o wer
P ow er
In pu t
Ou tp u t
V S WR
VS WR
S
ize
LxW x H
Ba la nc e
Ba la nc e
Fo rwa rd
Re ve rse
(d B )
( ±d B )
( ± °)
(W)
(W)
min
ma x
ma x
20
0 .2
2
10
2
1 .2
1 .1 5
20
0 .3
3
10
2
1 .2 5
1. 2
4 3 x56 x1 0
20
0 .4
5
10
2
1 .3
1. 2
63 x1 0 8 x10
20
0 .2
2
10
2
1 .2 5
1. 2
2 8 x28 x1 0
18
0 .3
-
10
2
1 .3
1. 3
5 2 x41 x1 0
20
0 .3
3
10
2
1 .3
1. 2
4 3 x56 x1 0
20
0 .4
5
10
2
1 .3
1. 2
63 x1 0 8 x10
25
0 .2
1 .5
10
2
1 .2
1. 2
2 8 x28 x1 0
20
0 .3
3
10
2
1 .2 5
1. 2
2 8 x28 x1 0
18
0 .3
3
10
2
1 .3
1 .2 5
4 3 x56 x1 0
18
0 .4
4
10
2
1 .5
1 .2 5
63 x1 0 8 x10
18
0 .4
5
10
2
1 .5
1. 5
3 0 x24 x1 0
16
0 .5
8
10
2
1 .6
1. 5
45 x5 0 .5 x1 0
18
0 .8
10
10
2
1 .8
1. 5
57 .5 x1 0 1 .5 x10
18
0 .8
-
10
2
1 .6
1. 5
3 2 x39 x1 0
18
0 .8
-
10
2
1 .8
1. 6
50 x7 5 .5 x1 0
15
0 .8
10
10
2
1 .8
1. 5
76 x1 5 4 x10
P/ N
JX WB GF-T-2-1 0 00 -2 00 0 -2
1-2
2
JX WB GF-T-4-1 0 00 -2 00 0 -2
1-2
4
JX WB GF-T-8-1 0 00 -2 00 0 -2
1-2
8
JX WBG F-T-2 -2 00 0 -40 0 0
2-4
2
JX WBG F-T-3 -2 00 0 -40 0 0
2-4
3
JX WBG F-T-4 -2 00 0 -40 0 0
2-4
4
JX WBG F-T-8 -2 00 0 -40 0 0
2-4
8
JX WBG F-T-2 -3 10 0 -34 0 0
3 . 1-3 .4
2
JX WBG F-T-2 -4 00 0 -80 0 0
4-8
2
JX WBG F-T-4 -4 00 0 -80 0 0
4-8
4
JX WBG F-T-8 -4 00 0 -80 0 0
4-8
8
J XWB G F-T-2 -60 0 0-1 8 00 0
6 -18
2
J XWB G F-T-4 -60 0 0-1 8 00 0
6 -18
4
J XWB G F-T-8 -60 0 0-1 8 00 0
6 -18
8
J XWB G F-T-3 -80 0 0-1 8 00 0
8 -18
3
J XWB G F-T-6 -80 0 0-1 8 00 0
8 -18
6
JX WB GF-T-12 -8 00 0 -18 0 00
8 -18
12
m
ax
0 .3
5
0.
6
1.
0
0 .3
5
0.
6
0.
6
0.
8
0.
3
0.
6
1.
0
1.
2
0.
7
1.
3
2.
2
1.
2
2.
2
2.
2
(m
m)
2 8 x28 x1 0
Notes:
1. Operating Temperature: -55 ºC to +85 ºC, Storage Temperature: -55 ºC to +95 ºC.
2. Applications: Indoor, 0-95%RH.
3. Forward power is tested with the output VSWR 1.5:1 of the loads. The power handling will be cut down when
the output port connect with a high VSWR. Ensure the output VSWR<1.5, avoiding output port open or short.
4. The power handling capability is 10 watts when used as divider with the load VSWR<1.2, the power handling
down to 2 watts when used as combiner.
5. Ensure connectors to be in flat connection with outer connectors; suggest using a torque wrench.
6. Custom Designs Available
American Accurate Components, Inc.
188 Technology Drive, Unit H, Irvine, CA 92618
Tel: 949-453-9888 Š Fax: 949-453-8889 Š Email: [email protected]
1