ADAM-TECH RT2-24

RELAY
SIGNAL RELAY THRU-HOLE-RT2
Adam Technologies, Inc.
R SERIES
INTRODUCTION:
Adam Tech RT2 relays are small signal level relays whose footprint
matches a standard 16 pin DIP socket and are available with coil
voltages from 5~48VDC. These 2 form C relays are designed for all
signal applications up to 2 amps, such as security equipment, test
equipment and medical equipment
FEATURES:
High sensitivity: 200 mW nominal operating power.
2 Amp switching capability
Power consumption of 200mW
High mounting density on P.C.board by small size and light weight.
Sealed construction.
ORDERING INFORMATION
SIGNAL RELAY
SPECIFICATIONS:
ELECTRICAL:
Contact arrangement: 2 Form C
Contact material: Gold clad, Silver Alloy
Contact Rating (Resistive load): 1A @ 120V AC
2A @ 30V DC
Max. Switching Voltage: 120V AC / 30V DC
Max. Switching Power: 100VA / 60W
Contact resistance: 100 mΩ max. Initial
Insulation resistance: 100 MΩ min. @ 500V DC
Dielectric withstanding voltage:
Between Coil & Contact: 500V AC 50/60Hz for 1 min.
Between Contacts: 1000V AC 50/60Hz for 1 min.
Operating time: 6 ms max.
Release time: 4 ms max.
Electrical Life: 100,000 Operations (at rated load)
RT2
SERIES INDICATOR
RT2 = Signal Relay
12
COIL VOLTAGE
5 = 5V DC
6 = 6V DC
12 = 12V DC
24 = 24V DC
48 = 48V DC
MECHANICAL:
Vibration resistance (Endurance): 1.5mm Double Amplitude 10-55Hz
Shock resistance: 10G min.
Mechanical Life: 10,000,000 Operations (no load)
TEMPERATURE RATING:
Ambient temperature: -40°C to +85°C
PACKAGING:
Anti-ESD plastic tubes
Tape & Reel
SAFETY AGENCY APPROVALS:
cUL Recognized File No. E305638
Pb
UL
®
®
c
US
V
RoHS
D E
®
COMPLIANT
2002 / 95 / EC
RoHS
COMPLIANT
52
909 Rahway Avenue • Union, New Jersey 07083 • T: 908-687-5000 • F: 908-687-5710 • WWW.ADAM-TECH.COM
RoHS
COMPLIANT
RELAY
SIGNAL RELAY THRU-HOLE RT2
Adam Technologies, Inc.
R SERIES
RT2 SERIES
.433
[11.00]
MAX
.826 [21.00]
MAX.
.472 [12.00]
MAX.
.157 [4.00]
.012
[0.30]
.023 [0.60]
.300
[7.62]
.200 [5.08]
.300 [7.62]
.200 [5.08]
ø.031
[0.80] TYP.
.200
[5.08]
.300
[7.62]
.200
[5.08]
RT2-24
Recommended PCB Layout
Schematic
SCHEMATIC
Nominal
Voltage
V DC
Pick-up Voltage
V DC (max.)
Drop-out
Voltage
V DC (min.)
Nominal
Operating Current
mA (±10%)
Coil Resistance
(±10%)
Nominal
Operating Power
mW
Max allowable
Voltage
V DC
5
3.5
0.5
40
125
200
10
6
4.2
0.6
33.3
180
200
12
12
8.4
1.2
16.7
720
200
24
24
16.8
2.4
8.3
2,880
200
48
48
33.6
4.8
6.3
7,680
300
86
909 Rahway Avenue • Union, New Jersey 07083 • T: 908-687-5000 • F: 908-687-5710 • WWW.ADAM-TECH.COM
53