Altech UL1077 TR11 Series E209569 up to 12 Amps UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment Applications: Protection of single phase Motors, Transformers, UPS, Power strips, Solenoids etc., against damage due to overcurrent conditions. Current Rating 240V AC, 50/60Hz, 32V DC / 24V DC (VDE) Initial insulation resistance Power Loss Operating Temperature Operational Life at 2xIn Limited short circuit current (As per EN 60934) > 100 M ohms. (As per EN 60934) 1.5 KV for One minute. 6 In ~ up to 9.0A (As per EN 60934) 4 In - up to 12.0A 60A Max. ~ from 10.0A to 12.0A 60A Max. - from 10.0A to 12.0A 8x In for <6.0A 60A MAX. for > 6.0A 1 - 2 Watts Maximum 60°C Ambient 1000 Cycles 1000 Amps PC 1 Terminals 0.25” Quick connect Applicable Standards EN 60934, CSA 22.2 No. 235, UL-1077 Dielectric strength Overload Switching Capacity Maximum Breaking Capacity up to 16.0 A Approvals 5 1 (S) 50 20 upto 12.0A 10 Dust Cover, DC-TR11 C (see page 14) Time Current Characteristics: The standard characteristic is valid for ambient temperatures of +23°C. If the device is to be used in an ambient temperature other than +23°C, allowances must be made when selecting the current rating according to the following guidelines: 16 (min) 60 30 20 10 Ambient temp. °C -20 0 +10 +20 +30 +40 +50 +60 Correction Factor 0.8 0.88 0.9 0.96 1 1.05 1.12 1.2 1.3 -5 Normal Continuous Current Ambient Temperature Correction Factor Recommended Current Rating Select the nearest : : : : : 1.8A 40°C 1.12 1.8 x 1.12 = 2.016 2.0A 5 2 1 Trip time Accessories Example : Operating Characteristic 0.5 -16.0A Rated Voltage 0.5 0.2 0.1 1.05 1.32 2 3 4 5 8 10 Multiple of Rated Current Rated current Ambient Temperature <6A >6A 23°C Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com TR-11 Characteristics & Mounting Options Central Mounting Standard Pack: 10 Weight: 0.27kg (0.6 lb.) Snap Fitting* Standard Pack: 10 Weight: 0.27kg (0.6 lb.) E209569 Rated Current 0.5A 0.9A 1.0A 1.2A 1.5A 1.8A 2.0A 2.2A 2.5A 2.7A 3A 3.3A 4A 5A 6A 6.5A 7A 8A 9A 10A 12A 15A 16A Type/ Cat. No. TR-11CX630.5A TR-11CX630.9A TR-11CX631A TR-11CX631.2A TR-11CX631.5A TR-11CX631.8A TR-11CX632A TR-11CX632.2A TR-11CX632.5A TR-11CX632.7A TR-11CX633A TR-11CX633.3A TR-11CX634A TR-11CX635A TR-11CX636A TR-11CY636.5A TR-11CY637A TR-11CY638A TR-11CY639A TR-11CY6310A TR-11CY6312A TR-11CY6315A TR-11CY6316A Rated Current Type/ Cat. No. up to 12 Amps Rated Current Type/ Cat. No. Rated Current Type/ Cat. No. Wing Clips* Standard Pack: 10 Weight: 0.27kg (0.6 lb.) Integral Mounting* Standard Pack: 10 Weight: 0.27kg (0.6 lb.) * SPECIAL ORDER ONLY. Contact Altech for more details. PCB Mounting and additional Shunt Terminal available, please contact Altech. Altech UL1077 Application Examples: Protection of single phase Motors, Transformers, UPS, Power strips, Solenoids etc., against damage due to overcurrent conditions. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 17 Central Mounting DIA 4 10 MAXIMUM TORQUE 0.5 Nm 9 6 10.8/12 7 9 0.8 DIA 4 9.4 10.2 Alternate 1 Alternate 2 15 DIA 12 Ø1 3 15.5 27.5 11 PANEL CUTOUT 15 9+0.1 12 14.5 5 .5 Wing Clips 8.7 10.2 11 M10 X 1 PANEL CUTOUT 19 27.5 13.3/14.5 A/F 13 3 Altech UL1077 TR-11 Dimensions & Mounting Options 19 7 12.7 15.2 13.9 +0.1 0.8 DIA 4 12 PANEL CUTOUT X +0.1 2 21.7 .2 7 11 11.3 +0.1 14 25.6 11.2 13 8.5 Snap Fitting 15 0.8 9 10 27.5 19 7 11 11.2 DIA 4 85 Integral Mounting 15 0.8 15 2 18 Dust Cover M10 X 1 Dimensions in mm (to convert to inches multiply by 0.03937) 18 DIA 16 Cover is suitable for central mounting type circuit breaker to provide dust & splash protection (IP 54). Type/Cat. No.: DC TR11 C Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com