VRLA Rechargeable Battery Measures BP10-12 (BP10-12FR) FEATURES Technology Values Innovation APPLICATION Maintenance free(no water topping-up required). No free acid(Non-spillable battery). Low self-discharge rate, lower than 3% capacity loss per month. Can be used in any orientation(excluding used inverted). UPS Laboratory Equipment SPECIFICATIONS Nominal Voltage Nominal Capacity Approx. Weight 12 V Terminals Internal Resistance Max. Discharge Current T2 (Faston Tab 250) T1 is optional ISO 9001 10.0Ah @ 20 hour rate F.V.(1.75V/cell) 3300g(7.28lbs.) 17m ISO14001 (Fully Charged ) Max. Charge Current 3.0 A Charge 0oC~40oC(32oF~104oF) Discharge -20oC~50oC(-4oF~122oF) Storage. -20oC~40oC(-4oF~104oF) Operating Temperature Range Container Material OUTER DIMENSIONS Terminal T1 151±1.5 (5.94±0.06) Width 4.75(0.19) 6.35(0.25) Constant power discharge characteristics at 25 oC/77 oF 1.80V 1.75V 1.70V 1.65V 1.60V Unit: W 5 Min 10 Min 15 Min 30 Min 361.6 266.2 213.3 126.9 72.78 29.15 20.10 11.23 5.91 418.5 288.4 223.1 131.7 74.96 29.73 20.40 11.40 6.00 444.6 298.7 230.0 134.7 76.31 30.00 20.51 11.46 6.04 464.6 305.9 235.3 136.6 77.23 30.21 20.58 11.49 6.05 480.0 312.0 240.0 138.0 78.00 30.39 20.64 11.49 6.05 o Constant current discharge characteristics at 25 C/77 F F.V. (V/cell) 7.85(0.31) 1 Hr o Discharge Time 0.8(0.03) 116 2(4.57 0.08) Total Height 116±2.0 (4.57±0.08) 3.4(0.13) 651. 5(2.56 0 .06) 151 1.5(5.940. 06) 112 1.5(4.41 0.06) Container Height 112±1.5 (4.41±0.06) Terminal T2 3.2(0.13) 65±1.5 (2.56±0.06) 1.80V 1.75V 1.70V 1.65V 1.60V IEC61056 JIS C 8702 GB/T 19639 TERMINAL TYPE Length F.V. (V/cell) CE ABS(UL94-HB, UL94-V0 is optional) DIMENSION(mm/inch) Discharge Time UL 150 A (5 sec.) 3 Hr 5 Hr 10 Hr 20 Hr Unit: A 5 Min 10 Min 15 Min 30 Min 1 Hr 3 Hr 5 Hr 10 Hr 20 Hr 32.57 23.43 18.55 10.75 6.12 2.43 1.675 0.936 0.493 38.39 25.38 19.40 11.16 6.30 2.48 1.700 0.950 0.500 40.79 26.30 20.00 11.42 6.41 2.50 1.709 0.955 0.503 42.62 26.93 20.46 11.58 6.49 2.52 1.715 0.958 0.504 44.04 27.46 20.87 11.69 6.55 2.53 1.720 0.958 0.504 All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto. A/0 REV. Jul. 2009 Powered by B.B. Battery Co., Ltd.