Bothhandusa.com ADSL LINE TRANSFORMER . P/N: AD-1102S DATA SHEET Feature ! ! ! ! ! ! ! Designed to meet UL 1950 and IEC 950 safety requirements. Meets IEC 695,2-2 flammability requirements. PWB Process Capability: standard printed wiring board assembly techniques, total-immersion cleaning. Reliability testing: shock, vibration, temperature cycling, temperature – humidity – bias. Minimum inter winding breakdown voltage 1500 Vrms. Operating Temperature: -10℃ to+60℃. Storage Temperature: -25℃ ℃ to +75℃ ℃. Electrical Specifications @ 25°C Part Turn Ratio (±2%) DCR (Ω Max) Longitudinal Balance Number (1-3):(2-4):(10-8):(9-7) (1-3)=(2-4) (10-8)=(9-7) (dB Min) AD-1102S 1:1:2:2 6 7 -60 3 Additional Specifications 2 Insertion Loss Number (dB Max) (dB Max) (dB Min) AD-1102S -4 -10 -85 Schematic Return Loss 1 Part Harmonic Distortion 4 5 Indcutance (mH ±10%) @(1-4) / shorted (2-3) 3.125 Mechanical 462 Boston St - Topsfield, MA 01983 - Phone: 978-887-8050 - Fax: 978-887-5434 A1(03/01)