BOTHHAND AD

Bothhandusa.com
ADSL LINE TRANSFORMER
P/N: AD-3442S DATA SHEET
Feature
!
!
!
Excellent Longitudinal Balance performance.
Operating temperature range: 0℃ to +60℃.
Storage temperature range: -25℃ to +75℃..
Electrical Specifications @ 25°C
Turn Ratio
(±1%)
Part
Number
OCL (uH±6%)
@10KHz/0.1V
Leakage Inductance(uH typ)
@100 KHz/0.1V
TX
RX
(1-4):(16-9)
(2+3,11+14)
short
(5-8):(16-9)
(6+7,11+14)
short
(9-16),(11+14)
short
(9-16),
(1+4,2+3,11+14)
short
(9-16),
(5+8,6+7,11+14)
short
1:4
1:2
700
30
28
AD-3442S
Longitudinal
Balance
(dB Min)
(35KHz to 650KHz)
(9-16),(11+14)
short
-55
Additional Specifications
Part
Number
DC Resistance
(Ω Max)
Inter winding Capacitance(pF Max)
( @100KHz,0.1V)
line
chip-Tx
chip-Rx
(9-16),(11+14) (1-4),(2+3) (5-8),(6+7)
short
short
short
AD-3442S
3.5
0.98
1.74
Schematic
(1-16),(2+3,11+14)
short
50
(9-8),(6+7,11+14)
short
Impedance
(Ω-Nom)
line
100
HI-POT
(Vrms Min)
Chip
Tx
Rx
5.6
300
Mechanical
462 Boston St - Topsfield, MA 01983 - Phone: 978-887-8050 - Fax: 978-887-5434
1875