BOTHHAND BP

BP Series
2 to 6 Watt Isolated DC-DC Converter
Single / Dual Output
1. Features :
! Wide 4:1 Input Range
! Low Ripple and Noise
! Input / Output Isolation 1.5K Vdc or 3.5K Vdc
! 100 % Burn-In
! Input π- Filter
! Custom Design Available
2. Absolute maximum ratings:
( Exceeding these values may damage the module. These are not continuous operating ratings )
Parameter
Condition
Min.
Typ.
Max.
24V Input Model
-0.7
24
45
48V Input Model
-0.7
48
90
Vdc
Input Absolute Voltage Range
Output Short circuit duration
Reverse Polarity Input current Limit
Operating temperature
Unit
Nominal Input Range
Indefinite & Auto-Restart
---
---
---
1
Output Full Load
-25
---
+71
-55
---
+105
Storage temperature
A
℃
3. Nominal Input / Output Electrical Specifications :
( Specifications typical at Ta = +25℃, nominal input voltage, rated output current unless otherwise noted )
Parameter
Condition
Min.
Typ.
Max.
24V Input Model
9
24
36
48V Input Model
18
48
75
Output full Load
---
---
± 0.5
Single Output Model
---
---
± 0.5
Input Voltage Range
Line Regulation
Unit
Vdc
Load Regulation
Dual Output Model
Output Voltage Accuracy
Output Voltage Balance
±2
Nominal Input
---
± 1.0
± 2.0
Dual Output at same Load
---
---
± 1.0
---
250
---
KHz
---
± 0.01
± 0.02
%/ ℃
Standard Series
1500
---
---
High Isolation Series
3500
---
---
500 Vdc
1000
---
---
MΩ
1 KHz / 250 mV rms
---
350
---
pF
Switching Frequency
Nominal Input
Temperature Coefficient
Isolation Voltage
Isolation Resistance
Isolation Capacitance
%
Vdc
BOTHHAND USA. http://www.bothhand.com
BP Series
2 to 6 Watt Isolated DC-DC Converter
Single / Dual Output
4. Single Output Selection Guide:
:
( Specifications typical at Ta = +25 ℃, Nominal input voltage, Rated output current unless otherwise noted )
Input
Output
Output
Input Current Input Current
Output
Load
Voltage
Voltage
Current
@ No Load
@ Max. Load
Ripple
Regulation
(Vdc)
(Vdc)
(mA) Max
(mA) Typ.
(mA) Typ.
(mV) Max.
(%) Max.
5.0
400
19
113
50
± 0.5
74
12.0
167
20
110
100
± 0.5
76
BP-2415S2
15.0
134
21
107
120
± 0.5
78
BP-4805S2
5.0
400
10
58
50
± 0.5
72
12.0
167
12
56
100
± 0.5
75
15.0
134
13
55
120
± 0.5
76
5.0
800
19
219
50
± 0.5
76
12.0
333
20
213
50
± 0.5
78
BP-2415S4
15.0
267
22
209
100
± 0.5
80
BP-4805S4
5.0
800
10
105
50
± 0.5
79
12.0
333
13
104
100
± 0.5
80
15.0
267
15
101
120
± 0.5
83
5.0
1200
25
321
50
± 0.5
78
12.0
500
27
313
100
± 0.5
80
BP-2412S6
15.0
400
27
309
120
± 0.5
81
BP-4805S6
5.0
1200
15
158
50
± 0.5
79
12.0
500
17
154
100
± 0.5
81
15.0
400
17
152
120
± 0.5
82
Bothhand
Efficiency
Model No.
(%) Typ.
2 W Single output Series
BP-2405S2
BP-2412S2
BP-4812S2
9 ~ 36
18 ~ 75
BP-4815S2
4 W Single output Series
BP-2405S4
BP-2412S4
BP-4812S4
9 ~ 36
18 ~ 75
BP-4815S4
6 W Single output Series
BP-2405S6
BP-2412S6
BP-4812S6
BP-4815S6
9 ~ 36
18 ~ 75
BP-xxxxSx
Notes:
1.
Standard output Voltage is 3.3V, 5V, 9V, 12V, 15V,
BP-xxxxSx is for Customer Design.
2.
Load regulation is for output current change from 0 % to 100 % Max. Load.
3.
Suffix “H” for 3.5K Vdc Isolation ….. ( BP-xxxxSxH )
4. Suffix “M” for Metal case …………... ( BP-xxxxSxM )
BOTHHAND USA. http://www.bothhand.com
BP Series
2 to 6 Watt Isolated DC-DC Converter
Single / Dual Output
Mechanical Dimension: ( Single O/P )
(1). Plastic Case:
Case:
Pin
1
2
Pin
---
---
24
-Vin
+Vin
23
3
22
4
21
5
20
6
(2). Nickel Coated Metal Case:
Case:
Single Output
---
---
19
7
18
8
17
9
NC
Vo (-)
16
10
---
---
15
11
NC
Vo (+)
14
12
---
---
13
Note:” --- “ means Omitted
Units : mm ( inch )
Tolerance : .xx ± 0.25
( ± 0.01 )
BOTHHAND USA. http://www.bothhand.com
BP Series
2 to 6 Watt Isolated DC-DC Converter
Single / Dual Output
5. Dual Output Selection Guide:
:
( Specifications typical at Ta = +25 ℃, Nominal input voltage, Rated output current unless otherwise noted )
Input
Output
Output
Input Current Input Current
Output
Load
Voltage
Voltage
Current
@ No Load
@ Max. Load
Ripple
Regulation
(Vdc)
(Vdc)
(mA) Max
(mA) Typ.
(mA) Typ.
(mV) Max.
(%) Max.
± 5.0
± 200
19
116
50
±2
72
± 12.0
± 83
20
111
100
±2
75
BP-2415D2
± 15.0
± 67
21
112
120
±2
75
BP-4805D2
± 5.0
± 200
10
56
50
±2
74
± 12.0
± 83
12
55
100
±2
75
± 15.0
± 67
13
55
120
±2
76
± 5.0
± 400
25
214
50
±2
78
± 12.0
± 167
27
209
100
±2
80
BP-2412D4
± 15.0
± 133
28
208
120
±2
80
BP-4805D4
± 5.0
± 400
18
105
50
±2
79
± 12.0
± 167
20
104
100
±2
80
± 15.0
± 133
20
104
120
±2
80
± 5.0
± 600
25
325
50
±2
77
± 12.0
± 250
27
313
100
±2
80
BP-2412D6
± 15.0
± 200
27
313
120
±2
80
BP-4805D6
± 5.0
± 600
18
160
50
±2
78
± 12.0
± 250
20
156
100
±2
80
± 15.0
± 200
20
156
120
±2
80
Bothhand
Efficiency
Model No.
(%) Typ.
2 W Dual output Series
BP-2405D2
BP-2412D2
BP-4812D2
9 ~ 36
18 ~ 75
BP-4815D2
4 W Dual output Series
BP-2405D4
BP-2412D4
BP-4812D4
9 ~ 36
18 ~ 75
BP-4815D4
6 W Dual output Series
BP-2405D6
BP-2412D6
BP-4812D6
BP-4812D6
9 ~ 36
18 ~ 75
BP-xxxxDx
Notes:
1.
BP-xxxxDx is for Customer Design.
2.
Load regulation is for Each output current change from 20 % to 100 % Max. Load.
3.
Suffix “H” for 3.5K Vdc Isolation …… ( BP-xxxxDxH )
4.
Suffix “M” for Metal case ……….…… ( BP-xxxxDxM )
BOTHHAND USA. http://www.bothhand.com
BP Series
2 to 6 Watt Isolated DC-DC Converter
Single / Dual Output
Mechanical Dimension: ( Dual O/P )
(1). Plastic Case:
Case:
Pin
1
2
Pin
---
---
24
-Vin
+Vin
23
3
22
4
21
5
20
6
(2). Nickel Coated Metal Case:
Case:
Dual Output
---
---
19
7
18
8
17
9
Common
Common
16
10
---
---
15
11
Vo (-)
Vo (+)
14
12
---
---
13
Note:” --- “ means Omitted
Units : mm ( inch )
Tolerance : .xx ± 0.25
( ± 0.01 )
BOTHHAND USA. http://www.bothhand.com