BOTHHAND SL100TX

Bothhandusa.com
SL100TX
100 Base-TX SIL Filter
General Information
1.
2.
3.
4.
5.
Application For 155 ATM, 100 Base-TX & TP-FDDI
Low Insertion loss characteristics
Integrated Filter and isolation transformer in 7 PIN SIL package
Operating temp range: 0°C to +70°C.
Storage Temp Range: -25°C to +125°C.
Electrical Characteristics @ 25ºC
1. Insertion Loss:
Attenuation:
Frequency
LOG
30KHz
-3 dB MAX
100KHz
-1.20
32MHz
-1
62MHz
-1
160MHz
-2
180MHz
-4
2. 100 OHM Return Loss:
Frequency
LOG
32 MHz
-20 dB MIN
62
-15
100
-11
3. Differential to common mode rejection:
FREQUENCY
LOG
32 MHz
-50 dB MIN
62
-45
100
-40
200
-25
4. Inductance:(100%)at 100 KHz,0.2V (1-2)=400 uH Min with 8 mA of DC bias applied when measured
on an RCL1692 or equivalent
6. Hi-Pot Test: 1650 Vrms/0.5mA 1 Sec.
Schematic & Dimensions & Marking (Unit mm):
Bothhand USA 462 Boston St Topsfield, MA 01983
Phone: 978-887-8050
www.bothhandusa.com
Fax: 978-887-5434
[email protected]