CANDD NTE

NTE SERIES
Isolated 1W Single Output SM DC-DC Converters
SELECTION GUIDE
Nominal
Input
Voltage
Output
Voltage
Output
Current
(V)
(V)
(mA)
NTE0303M
3.3
3.3
303
410
NTE0305M
3.3
5
200
390
NTE0503M
5
3.3
303
270
74
40
619
NTE0505M
5
5
200
294
68
35
2418
NTE0505ME
5
5
200
260
77
40
419
NTE0509M
5
9
111
267
75
43
1174
FEATURES
NTE0512M
5
12
83
260
77
42
634
■ Wide Temperature Performance at
Full 1 Watt Load, –40°C to 85°C
NTE0515M
5
15
66
256
78
44
360
NTE1205M
12
5
200
124
67
47
621
■ Lead Frame Technology
NTE1209M
12
9
111
114
73
77
488
■ CECC00802 Reflow (280°C)
NTE1212M
12
12
83
113
74
88
360
■ Single Isolated Output
NTE1215M
12
15
66
111
75
95
252
■ 1kVDC Isolation
When operated with additional external load capacitance the rise time of the input voltage will determine the
maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the
greater the maximum value of the additional external capacitance for reliable start up.
O rd e rC o de 5
■ Efficiency to 78%
■ Power Density 1.8W/cm 3
■ 3.3V, 5V & 12V Input
■ UL 94V-0 Package Material
■ No Heatsink Required
■ Internal SMD Construction
73
30
1234
78
35
632
MIN
TYP
MAX
Voltage Range
3.30
5
12
30
3.63
5.5
V
13.2
47 mA p-p
TYP
MAX
Units
1.0
W
1.0
1.2
%/%
10
14
12.8
8.3
6.8
6.3
15
9.0
7.5
7.0
40
60
62
49
39
38
85
75
65
76
Reflected Ripple Current
Units
OUTPUT CHARACTERISTICS
Parameter
Conditions
TA = -40°C to 85°C
■ Multi Layer Ceramic Capacitors
■ Lead Free Compatible
Load Regulation 3
DESCRIPTION
www.dc-dc.com
kHrs
Conditions
Rated Power2
Voltage Set Point
Accuracy
Line regulation
The NTE series of miniature surface mounted
DC-DC Converters employ leadframe
technology and transfer moulding techniques
to bring all of the benefits of IC style
packaging to hybrid circuitr y. The devices are
fully compatible with CECC00802 to 280°C
which allows them to be placed and reflowed
with IC’s, thus reducing time and cost in
production. The co-planarity of the pin
positions is based upon IEC 191-6:1990.
The devices are suitable for all applications
where high volume production is envisaged.
(pF)
Continuous operation, 3.3V input types 2.97
Continuous operation, 5V input types
4.5
Continuous operation, 12V input types 10.8
■ Plastic Encapsulated
■ MTTF up to 2.9 Million Hours
(%)
Parameter
■ Toroidal Magnetics
■ Custom Solutions Available
(mA)
Isolation
Capacitance MTTF1
INPUT CHARACTERISTICS
■ 3.3V, 5V, 9V, 12V and 15V Output
■ Footprint Over Pins 1.64cm 2
Input
Current at
Rated Load Efficiency
Ripple and Noise
MIN
See tolerance envelope
High VIN to low V IN
10% load to rated load,
0303M, 0305M, 0503M, 0505ME
10% load to rated load, 5V output types
10% load to rated load, 9V output types
10% load to rated load, 12V output types
10% load to rated load, 15V output types
BW=DC to 20MHz,
0303M, 0305M, 0503M, 0505ME types
BW=DC
BW=DC
BW=DC
BW=DC
to
to
to
to
20MHz,
20MHz,
20MHz,
20MHz,
5V output types
9V output types
12V output types
15V output types
ABSOLUTE MAXIMUM RATINGS
Short circuit duration 4
Internal power dissipation
Lead temperature 1.5mm from case for 10 seconds
Input Voltage VIN , NTE03 types
Input Voltage VIN , NTE05 types
Input voltage V IN , NTE12 types
1
2
3
4
5
1second
600mW
300°C
5.5V
7V
15V
Calculated using MIL-HDBK-217F with nominal input voltage at full load.
See derating curve.
12V input types have typically 3% less load regulation change.
Supply voltage must be discontinued at the end of the short circuit duration.
If components are required in tape and reel format suffix order code with -R, e.g. NTE0505M-R
All specifications typical at TA =25°C, nominal input voltage and rated output current unless otherwise specified.
%
mV p-p
NTE SERIES
Isolated 1W Single Output SM DC-DC Converters
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation Test Voltage
Resistance
Flash tested for 1 second
Viso=1000VDC
MIN
TYP
MAX
Units
1000
10
VDC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching Frequency
All variants
MIN
TYP
MAX
Units
110
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
MIN
Specification
Storage
All output types
–40
–55
0303M, 0305M, 0503M, 0505ME
0505M, 1205M
All other output types
Free air convection
Case Temperature
above ambient
Cooling
TYP
MAX
Units
85
125
°C
°C
30
40
40
°C
PERFORMANCE CHARACTERISTICS
TEMPERATURE DERATING
tolerance envelope (3.3V output types)
tolerance envelope (all other types)
+9%
2.0
+10%
+5%
+1%
VNOM
+1%
+2.5%
VNOM
-7%
-7%
1.5
-2.5%
-7.5%
0.5
-15%
85°C
1.0
Safe Operating Area
0
-40
10
25
50
75
Output Load Current (%)
100
10
25
50
75
Output Load Current (%)
100
0
50
100
Ambient Temperature (°C)
MECHANICAL DIMENSIONS
12.70
7.62
14 12 10
11.20 7.70
10.40
DETAIL A
8
REFERENCE
PLANE
NTE0505M
3
5
2.54
1.50
1.20
7
±5.00°
DETAIL A
S SEATING PLANE
NA – Not available
for electrical connection
P
XYYWW
1
PIN
1 GND
3
VIN
5
NA
7
0V
8
+V
10
NA
12
NA
14 NA
0.5
10 PINS
0.65
0.2 M S
0.55 P
2.10
6.60 (6.35)
(5.95) 5.85
0.25
0.10
2.79MAX
1.875
MAX
0.1 S
0.30
0.20
Weight: 1.21g
All dimensions in mm XX.XX ±0.25mm. All pins on a 2.54mm pitch.
C&D Technologies (NCL) Limited reserve the right to alter or improve the
specification, internal design or manufacturing process at any time, without
notice. Please check with your supplier or visit our web site to ensure that
you have the current and complete specification for your product before use.
© C&D Technologies (NCL) Limited 2001
NDC NTE.4
No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to,
photography, photocopy, magnetic or other recording means, without prior
written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.dc-dc.com
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North
Milton Keynes MK14 5BU, England
Tel: +44 (0)1908 615232
Fax:+44 (0)1908 617545
email: [email protected]
www: http://www.dc-dc.com
C&D Technologies (NCL), Inc.
5816 Creedmoor Road, Raleigh
NC 27612, USA
Tel: +1 (919) 571-9405
Fax: +1 (919) 571-9262
email: [email protected]
150